Page 2 - Listing Label Information/Location; We recommend that you record the following pertinent; Homeowner Reference Information; Read this manual before installing or operating this appliance.; NA; XXXXXXXX
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location...
Page 3 - Safety Alert Key:; Table of Contents; User Guide
3 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.• WARNING! Indicates a hazardous situation which, if not avoided could result in ...
Page 4 - 6 Reference Materials
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 4 = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 53B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 6 - B. Limited Lifetime Warranty
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 6 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is ava...
Page 7 - This appliance is tested and approved as either supplemen-; NOTICE: This installation must conform with local codes.; Listing and Code Approvals; Models; NOTICE: If the heating value of the gas has been reduced,; Standard Test Method for Behavior of Materials in a; NOTICE: This appliance must be electrically wired and; National Electric Code ANSI/NFPA
7 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 C. BTU Specifications MODELS: 6000CL-IPI, 6000CL-IPILP, 8000CL-IPI, 8000CL-IPILP LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.88b-2008 • CSA...
Page 8 - NOT; The following requirements referenc e var ious
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residenti...
Page 9 - WARNING! DO NOT operate fireplace before read; A. Gas Fireplace Safety; WARNING; This appliance has been supplied with an integral barrier; HOT SURFACES; Operating Instructions
9 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fireplace before read - ing and understanding operating instructions. Failure to operate fireplace according to operating ins...
Page 10 - F. Fixed Glass Assembly; WARNING! Risk of Fire! Install ONLY doors or fronts; G. Remote Controls, Wall Controls and Wall
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 10 D. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive o...
Page 11 - J. Before Lighting Fireplace; have a; erate fireplace with fixed glass assembly removed.; I. Control Module Operation; Module Reset; ule more than one time within a five minute time period.; H. IPI Battery Tray/Battery Installation; NOTICE: Batteries should only be used as a power source; Nine Hour Safety Shutdown Feature
11 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 J. Before Lighting Fireplace Before operating this fireplace for the first time, have a qualified service technician : • Verify all shipping materials have been removed from inside and/or underneath th...
Page 12 - NOT FOR USE; GAS; WHAT TO DO IF YOU SMELL GAS; DO NOT CONNECT LINE VOLT-; Also Certified for Installation in a; Final inspection by
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 12 K. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait five (5) minutes to clear out...
Page 13 - L. After Fireplace is Lit; ISSUE
13 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Initial Break-in Procedure• The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool.• Remove fixed glass assembly. See Section 14....
Page 14 - Glass Cleaning; Tools Needed; CAUTION! Handle fixed glass assembly with care.; Note; Maintenance and Service; The fireplace should be turned; Tools needed; Remote Control; Any safety screen or guard removed for servicing must be
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breaka...
Page 15 - DO NOT
15 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Maintenance Tasks-Qualified Service Technician The following tasks must be performed by a qualified ser- vice technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Qualified ...
Page 16 - C. Refractory, Grate and Valve Assembly; do not; The refractory must be removed; NOTICE: Remove refractory before removing grate. If; Refractory is Fragile.
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 16 Figure 3.3 Side Refractory Removal C. Refractory, Grate and Valve Assembly Removal It may become necessary to remove the refractory, grate and valve assemblies. This task should be performed by a quali...
Page 17 - BASE REFRACTORY; The base refractory must be
17 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 BASE REFRACTORY Figure 3.6 Valve Assembly Removal Note: The base refractory must be removed to access screws. Figure 3.5 Base Refractory Removal D. Burner Identification/Verification The burner may be ...
Page 18 - A. Typical Appliance System; drawn to scale. Actual product may vary from pictures in manual; Dual venting c onf igurations; ARE NOT; allowed. Appliance; MUST; b e ve nte d; E I T H E R; ve r t i c a l l y; O R; Getting Started; Installer Guide
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 18 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from ...
Page 19 - Read all of the instructions before starting the instal-; WARNING! Risk of Fire or Explosion! Damaged parts; C. Tools and Supplies Needed; Hearth & Home Technologies disclaims any responsibility for,; Any such action may cause a fire hazard.; DO NOT use this appliance if any part has been under; Improper installation, adjustment, alteration, service or
19 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled ...
Page 20 - Framing and Clearances; A. Selecting Appliance Location; When selecting a location for the appliance it is important to; Mantel Projections
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 20 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire...
Page 21 - B. Constructing the Appliance Chase; type of building. These instructions are not substitutes; NOTICE: Install appliance on hard metal or wood surfaces
21 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. ...
Page 22 - D. Mantel and Wall Projections; WARNING! Risk of Fire! Comply with all minimum clear-; Combustible Mantels; Measurement is taken from top of the
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 22 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of no...
Page 23 - A. Vent Termination Minimum Clearances; Termination Locations; pack air space with insulation or other
23 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ...............................................
Page 24 - regulator; public; Covered Alcove Applications; consider proximity to doors, traffic areas or where people
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 24 Figure 6.3 Minimum Clearances for Termination O N P R Q X = AIR SUPPLY INLET A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 12 inches.................clearanc...
Page 25 - ance requires a separate vent.; Vent Information and Diagrams; D. Measuring Standards; Horizontal
25 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fittings or j...
Page 27 - Two Elbows; Minimum
27 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 INSTALLED HORIZONTALLY H 1 H 2 V 1 Figure 7.4 Two Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow, to allow...
Page 28 - Three Elbows; Elbow only
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 28 Figure 7.5 Top Vent - Horizontal Termination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in...
Page 29 - Top Vent - Vertical Termination; If installing a vertical vent/; Break the flue restrictor into two pieces. Do this by; BREAK; Flue Restrictor Instructions; Remove the top piece of refractory, if already installed.
29 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 FLUE RESTRICTOR TOP REFRACTORY Top Vent - Vertical Termination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the appli- ance, the flue restrictor should be used. S...
Page 30 - Maximum
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 30 H 1 V 1 V 2 Top Vent - Vertical Termination (continued) Figure 7.11 Two Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). ...
Page 31 - Minimum H
31 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 7.12 Top Vent - Vertical Termination - (continued) Three Elbows INSTALLED HORIZONTALLY H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 3...
Page 32 - Do not use a 45o elbow in corner installations.
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 32 Rear Vent - Horizontal Termination Figure 7.14 No Elbow One 45º Elbow H 1 H 1 = 16 in. (406 mm) Maximum Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.13 H 1
Page 33 - Back to Back
33 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. 1...
Page 35 - Back to Back 90o Elbows
35 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1...
Page 36 - *No specific restrictions on this value EXCEPT
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 36 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum * * * 8 ft. 2.4 m 6 ft. 1.8 m * * * 9 ft. 2.7 m 7 ft. 2....
Page 37 - A. Pipe Clearances to Combustibles; WARNING! Risk of Fire! Maintain air space clearance to; Vent Clearances and Framing; B. Wall Penetration Framing; Combustible Wall Penetration
37 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A* B* 10 in. 12 in. C D 10 in. 12 in. A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fir...
Page 38 - C. Install the Ceiling Firestop; lation around the vent. Insulation must be kept
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 38 C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics.• DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/f...
Page 39 - D. Install Attic Insulation Shield; WARNING! Fire Risk. DO NOT allow loose materials or; Flat Ceiling Installation; Gas Kit; Vaulted Ceiling Installation; NOTICE: Cut previously installed batt insulation to make
39 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fu...
Page 40 - Appliance Preparation; Wear protective gloves and safety glasses during instal-
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 40 9 Appliance Preparation CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.NOTICE: Once appliance is set up ...
Page 42 - HEADER; D. Securing and Leveling the Appliance; • Sagging or loose insulation
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 42 Figure 9.14 Proper Positioning and Securing of an Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.12 Non-combustible Board C. Installing the Non-combustible Board The factory supplied non-comb...
Page 43 - Attach Vent to the Firebox Assembly; The end of the pipe sections with the lanced tabs will face; Assemble Pipe Sections; WARNING! Risk of Fire or Explosion! DO NOT break; Make sure that the seams are not aligned to prevent; INCORRECT; Lances
43 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the app...
Page 44 - rating; then rotate counterclockwise to lock; C. Assemble Slip Sections; Pilot hole; NOTICE: When installing a vent system with an HRC
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 44 B. Assemble Vent Sections (SLP Pipe Only) To attach the first vent component to the starting collars of the appliance:• Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • ...
Page 45 - E. Disassemble Vent Sections; Improper support may allow vent to sag and separate.
45 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 120º Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sec...
Page 46 - F. Install Decorative Ceiling Components
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 46 F. Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a flat ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the ...
Page 47 - G. Install Metal Roof Flashing; H. Assemble and Install Storm Collar; CAULK; Failure to properly caulk the roof flashing and
47 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe se...
Page 48 - I. Install Vertical Termination Cap; Heat shields may; K. Heat Shield Requirements for Horizontal; To prevent overheating and fire,
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 TERMINATION CAP I. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of t...
Page 49 - L. Install Horizontal Termination Cap (DVP; The telescoping flue section of; Cap Specification Chart
49 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 10.20 Venting through the wall INTERIOR HEAT SHIELD OR EXTENDED HEAT SHIELD WALL SHIELD FIRESTOP HEAT SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEATHING VENT DEPTH FROM BACK OF APPLIANCE TO OUTSIDE...
Page 50 - Gas Information; Gas Pressure; • If substituting for these components, please consult; D. High Altitude Installations
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and appr...
Page 51 - A. Wiring Requirements; NOTICE: This appliance must be electrically wired; National Electric Code; Ignition System Wiring; WARNING! Risk of Shock or Explosion! DO NOT wire; C. Optional Accessories Requirements; Electrical Information
51 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest e...
Page 52 - 10 VAC to wall switch.; E. Junction Box Installation; INSIDE; D. Electrical Service and Repair; WARNING! Risk of Shock! Label all wires prior to dis-
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 52 F. Wall Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3):• The power supply for the appliance must be brought into a switch...
Page 53 - Finishing; A. Mantel and Wall Projections; WARNING! Risk of Fire! DO NOT apply combustible
53 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 13 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing closer than the minimums list - ed must be constructed entirely of noncombu...
Page 54 - Halston; Inch Thick or Less; Remove finishing strips before firing appliance.
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 54 Figure 13.4 Finishing Material 1 Inch Thick or Less DOOR FIT FINISH MATERIAL THICKNESS SEE FIGURE Folio Inside Any 13.6 Arcadia Overlap 1 inch or less 13.4 Inside Greater than 1 inch 13.5 Halston Overl...
Page 55 - Finishing Material Thickness:
55 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 DOOR FINISHING MATERIAL FINISHING MATERIAL C (Includes 1/8 in. opening each side of door) A (Outside door width) Finishing material thickness, 1-4 inches maximum B = Top of door to bottom of fireplace....
Page 56 - Removal of Finishing Strips; FINISHING STRIPS REMOVED
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 56 Removal of Finishing Strips Figure 13.7 Removing Finishing Strips. 31-7/8 IN. (6000) 33-11/16 IN. (8000) 3-3/4 IN. (6000, 8000) 35-5/16 IN. (6000) 43 IN. (8000) Figure 13.8. Clean Face Door Dimensions ...
Page 57 - D. Elevated Hearth Systems; stallation dimensions.; Note 2. Verify Marble Cut Lengths on site prior to cutting.
57 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 D. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions. Some hearth systems will elevate the...
Page 58 - WARNING! Risk of Fire and Electric Shock! Use ONLY; Appliance Setup; E. Burner Top Installation
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 58 A. Remove Fixed Glass Assembly See Section 14.I. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. C. Clean the Appliance Clean/vacuum any sawdust that m...
Page 59 - Step 2. Right Refractory Panel Installation; F. Refractory Installation; Step 1. Back Refractory Panel Installation
59 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Step 2. Right Refractory Panel Installation The right refractory panel has a rectangular notch on the bottom side.3. Place the right refractory panel against the right side- wall of the firebox. Rest t...
Page 60 - Step 3. Left Refractory Installation
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 60 G. Ember Placement WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT completely block burner ports with ember material. Replace ember material annu- ally. Improperly pla...
Page 61 - H. Install the Log Assembly; : Locate log placement tabs on the pilot cover. Bend
61 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 H. Install the Log Assembly Log Assembly: LOGS-6CL Models: 6000CL-IPI-S, 6000CL-IPILP-S, 6000CL-IPI-T, 6000CL-IPILP-T CAUTION: Logs are fragile, handle with care. Log #1 (SRV2164-701) : Locate log plac...
Page 62 - securely against right hand side of log indentation.; pulled tight to the locating notch. Pivot the front (notched)
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 62 Figure 11 6 5 7 2 3 1 4 Figure 7 2 3 1 Log #3 (SRV2164-703) : Mate the slot located on the bottom of Log #3 with the right log placement tab on top of Log #1. After slot and tab have been fitted togeth...
Page 63 - Locate log placement tabs on the pilot
63 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Log Assembly: LOGS-8CL Models: 8000CL-IPI-S, 8000CL-IPILP-S, 8000CL-IPI-T, 8000CL-IPILP-T Figure 3 Figure 4 GROOVES SLOTS Figure 5 Figure 6 1 2 1 LEFT GRATE TINE CAUTION: LOGS ARE FRAGILE, HANDLE WITH ...
Page 64 - the far left grate tine as well as contact Log # 2.
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 64 Figure 11 1 2 3 4 5 6 7 Figure 7 2 3 1 1 2 3 4 Figure 8 Figure 9 Figure 10 1 1 2 2 3 3 4 5 5 6 4 Log #3 (SRV2168-703) : Mate the slot located on the bottom of Log #3 with the right log placement tab on...
Page 65 - I. Fixed Glass Assembly; Handle fixed glass; Removing Fixed Glass Assembly; Air Shutter Settings; K. Air Shutter Setting; NOTICE: If sooting occurs, provide more air by opening; NG; Fully Open
65 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 14.5 Air Shutter Figure 14.4 Fixed Glass Assembly I. Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and i...
Page 66 - Troubleshooting; Ignition System; Symptom; there is no noise or
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 66 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will as...
Page 68 - Reference Materials; A. Appliance Dimension Diagram; Location Inches
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 68 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance...
Page 70 - B. Vent Components Diagrams
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 70 B. Vent Components Diagrams Figure 16.3 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DV...
Page 71 - Horizontal Termination Cap; Max; The heat shield is designed to be; Heat; continued
71 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-HPCK1-B DVP-HPCK2-B DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Hea...
Page 73 - DVP High Performance Cap
73 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW Vertic...
Page 74 - HORIZONTAL TERMINATION CAP; Optional Wire Harness; Power Vent Inline
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 74 B. Vent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Lengt...
Page 75 - Effective Height/Length
75 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Vent Components Diagrams (continued) Figure 16.8 SLP Series Vent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 i...
Page 76 - Extended Heat Shield; Adapter
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 76 B. Vent Components Diagrams (continued) Figure 16.9 SLP Series Vent Components SLP-WT-BK Wall Thimble-Black 26 in. 660 mm DVP-HSM-B Extended Heat Shield SLP-TRAP Horizontal Termination Cap 15-1/8 in. (...
Page 78 - Service Parts; Beginning Manufacturing Date: Aug 2009; in this manual may be ordered from an authorized dealer.; Stocked; ITEM; Log Set Assembly; 6” Gas Fireplace - DV
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 78 Service Parts Beginning Manufacturing Date: Aug 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provi...
Page 82 - D. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; NOTICE
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 82 D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. - NOTES - _______...