- Page 2 – MOTOR COMPARTMENT; RELIEF
- Page 3 – REMOTE CONTROL WIRING
- Page 4 – GENERAL INSTRUCTIONS; Maxi-Flo pump should be cleaned with a mild detergent.; Note; : The Maxi-Flo package was not designed for use in outdoor; Graco endorses the SAE recommendation of ISO 18/14 (ISO 4406) oil; TRABON; COMPONENT ORDERING; Description; call
DESCRIPTION
Designed for machinery requiring oil lubrication, this self-contained,
easy-to-install package includes a reservoir, electric-motor-driven
positive displacement pump, gear
motor, and a choice of two control
systems with a low-level switch as standard equipment.
Optional accessories are a pressure gauge and a high pressure switch
which, when used with MS or MJ series type divider valves, provide an
economical means of effectively monitoring system operation.
Note
: Designing information for a Maxi-Flo system is available in
Bulletin No.
L
23110.
FEATURES / BENEFITS
Choice of (1) Solid-State Time Control, or (2) Remote Control
•
matches unit to application.
Easy installation. Just four mounting bolts and one electrical
•
connection.
Transparent reservoir provides visual indication of oil level.
•
Manual run push-button simplifies line filling, system bleeding or
•
purging, and/or testing system integrity.
Housing and reservoir are durable molded plastic.
•
Lights indicate low level, operating and power on.
•
Compact Pump / Control Package for automatic,
low-pressure, centralized oil lubrication systems.
Maxi-Flo
®
Pump Package
SPECIFICATIONS
Pump Output per Stroke
0.010 in
3
(0.165 cm
3
)
Pump Output per min of On-
Time
12 rpm @ 60 Hz
0.120 in
3
(1.97 cm
3
)
10 rpm @ 50 Hz
0.100 in
3
(1.64 cm
3
)
Max System Operating
Pressure
500 psi (34 bar)
Atmosphere Relief Indicator
Rating
600 psi (41 bar)
Lubricant
Oil, 60-30000 SUS
Operating Temperature
Min
0ºF (-18ºC)
Max - Intermittent
Operation
140ºF (60ºC), 50% duty cycle or less)
Max - Continuous Operation
120ºF (49ºC)
Reservoir Capacity
4 pints (1.9 liters), 116 in
3
(1890 cm
3
)
Pump Gearmotors
115V, 50/60 Hz, shaded pole, 12 rpm
output @ 60 Hz, 10 rpm @ 50 Hz, 0.13
amp running current, 0.185 amp inrush
current
Reservoir Low Level Switch
115 VAC, 10 Watt Load
Standard Control Systems
Time Control
Solid State Timer, 115 VAC, 50/60 Hz,
cycle time from 1/2 minute to 32 hours,
adjustable On-Time of 12 sec to 13
minutes
NOTE: If the On-Time is set greater or
equal to "Total Cycle Time" the timer will
cause the pump to run continuously
Remote Control
115 VAC, 50/60 Hz, terminal strip for
connection to machine control system
Accessories
Pressure Gauge
0-1000 psi (0-69 bar), back mount, 1/8
NPTF
High Pressure Switch
Factory set @ 550 psi (38 bar), 10
ampere contact rating @ 115 VAC
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Trabon ® Maxi-Flo ® Pump Package 13110 Page 2 OPERATION The pump gearmotor, energized by one of the three control units, rotates an eccentric (A) connected to a rod that drives the pump piston (B). On the prime stroke, the piston opens the inlet port (C), allowing oil from the reservoir to flow into...
Trabon ® Maxi-Flo ® Pump Package 13110 Page 3 DETAIL ON STANDARD AND OPTIONAL SWITCHES OPERATION WITH TIME CONTROL Set the slide switch to either minutes or hours for cycle time. Next, set the desired pump " ON TIME " using a screwdriver in the slotted head of the scale marked " ON TIME ...
ä ä DIMENSIONS Inches (mm) GENERAL INSTRUCTIONS Maximum pump pressure is 500 psi. Damage may result if pump is operated in excess of 600 psi. Relief valve automatically relieves output to atmosphere at 600 psi. Fill reservoir with clean, filtered oil - never allow pump to operate on an empty reservo...