Graco BULLDOG 222248- User Manual

Graco BULLDOG 222248

Graco BULLDOG 222248– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – SAFETY WARNINGS; MOVING PARTS HAZARD; General Safety; Safety Latch; Spray Tip/Nozzle Safety
  • Page 5 – OPERATION
  • Page 6 – MAINTENANCE
  • Page 7 – TROUBLESHOOTING GUIDE; WARNING; PROBLEM
  • Page 8 – DISPLACEMENT PUMP SERVICE; Model 204–641 Displacement Pump (Used on
  • Page 10 – Do not disassemble
  • Page 12 – PARTS DRAWING – STANDARD PUMPS; 0:1 Ratio King Pump; 0:1 Ratio Bulldog Pump; 0:1 Ratio Bulldog Pump; with Quiet Air Motor
  • Page 13 – PARTS LIST – STANDARD PUMPS; Must be purchased separately; Qty; O–ring 104–445 included in the kit is not used; HOW TO ORDER PARTS
  • Page 14 – PARTS DRAWING – SEVERE–DUTY PUMPS
  • Page 15 – PARTS LIST – SEVERE–DUTY PUMPS
  • Page 16 – ACCESSORIES; USE GENUINE GRACO PARTS AND ACCESSORIES; BLEED–TYPE MASTER AIR VALVE
  • Page 17 – GRACO THROAT SEAL LIQUID
  • Page 19 – ment Pump is advanced to Series B.
  • Page 20 – THE GRACO WARRANTY AND DISCLAIMERS; IMPORTANT PHONE NUMBERS
Loading the manual

INSTRUCTIONS–PARTS LIST

306–646

Rev R

Supersedes P

This manual contains IMPORTANT

WARNINGS AND INSTRUCTIONS

READ AND RETAIN FOR REFERENCE

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

Model 204–287 Shown

BULLDOG

and KING PUMPS

DRUM LENGTH, WITH PRIMING PISTON

10:1 RATIO BULLDOG PUMPS

100 psi (7 bar) MAXIMUM AIR WORKING PRESSURE

1000 psi (70 bar) MAXIMUM FLUID WORKING PRESSURE

Model 204–287, Series K

With Standard Air Motor

Model 215–873, Series B

With Quiet Air Motor

Model 222–526, Series A

With Standard Air Motor and Severe–Duty Displacement Pump

Model 223–984, Series A

With Quiet Air Motor and Severe–Duty Displacement Pump

20:1 RATIO KING PUMPS

90 psi (6 bar) MAXIMUM AIR WORKING PRESSURE

1800 psi (124 bar) MAXIMUM FLUID WORKING PRESSURE

Model 222–248, Series A

With Standard Air Motor

Model 222–539, Series A

With Standard Air Motor and Severe–Duty Displacement Pump

Model 223–991, Series A

With Quiet Air Motor and Severe–Duty Displacement Pump

TABLE OF CONTENTS

Warnings

2, 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Typical Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operation

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting Guide

7

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Displacement Pump Service

8–11

. . . . . . . . . . . . . . . . . . .

Parts Drawing – Standard Pumps

12

. . . . . . . . . . . . . . . .

Parts List – Standard Pumps

13

. . . . . . . . . . . . . . . . . . . . .

Parts Drawing – Severe–Duty Pumps

14

. . . . . . . . . . . . .

Parts List – Severe–Duty Pumps

15

. . . . . . . . . . . . . . . . .

How To Order Replacement Parts

13, 15

. . . . . . . . . . . . .

Accessories

16–18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensional Drawing

19

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Mounting Hole Layout

19

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Data

Back Cover

. . . . . . . . . . . . . . . . . . . . . . . . .

Warranty

Back Cover

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY WARNINGS; MOVING PARTS HAZARD; General Safety; Safety Latch; Spray Tip/Nozzle Safety

306–646 SAFETY WARNINGS HIGH PRESSURE FLUID CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read And Understand All Instruction Manuals Before Operating Equipment. MOVING PARTS HAZARD KEEP HANDS AND FINGERS AWAY FROM THE PRIMING PISTON DURING OPERATION AND WHENEVER THE PUM...

Page 5 - OPERATION

5 306–646 OPERATION WARNING Pressure Relief Procedure To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow this pro- cedure whenever you shut of f the pump, when checking or servicing any part of the ...

Page 6 - MAINTENANCE

6 306–646 MAINTENANCE Shutdown and Care of the Pump Always follow the Pressure Relief Procedure Warning on page 7 whenever you shut of f the pump. Stop the pump at the bottom of its stroke to keep fluid from drying on the exposed displacement rod and damaging the throat packings.Every 40 hours of op...

Other Graco Models

All Graco Other