Graco 715 - Manual
Graco 715 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 4 – DESCRIPTION OF OPERATION
- Page 5 – SETUP PROCEDURE; MOUNTING DISPENSE VALVE; OPERATING PROCEDURES; DRY SYSTEM CHECKOUT; section or call Technical Service at (330) 494
- Page 6 – OPERATION ADJUSTMENTS
- Page 7 – PERIODIC MAINTENANCE; DISPENSE NOZZLE/NEEDLE REPLACEMENT; The 715 Dispense Valve is now ready to be placed back in service.
- Page 8 – MODEL 715 GENERAL ILLUSTRATION
- Page 9 – DISASSEMBLY - AIR CYLINDER ASSEMBLY
- Page 10 – MODEL 715 AIR CYLINDER ASSEMBLY ILLUSTRATION
- Page 11 – TROUBLESHOOTING
- Page 12 – Replacement Nozzles
- Page 13 – GENERAL GUIDELINES FOR O-RINGS AND U-CUP SEALS; U-cup Seal Guidelines
Instructions
Dispensit
715
Usage Statement – Depending on valve configuration this valve can be used to dispense the following:
Acrylics •
Urethanes • Lubricants • UV Curables • Silicone Oil • RTV Silicone • Sealants • Epoxies • Greases • Filled Materials • Heat
Sink Compounds
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Dispense Valve
No.)OartPartMeteri
ng Unit (
100
psi (0.69 MPa, 6.9 bar) Maximum Working Pressure
See Page 3 for model information, including maximum
working pressure and approvals.
332095A
EN
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
4 DESCRIPTION OF OPERATION 1. The normal “ready” state of the system is as follows: The material supply line is filled with dispensable material. The system has been purged, filling the valve with material up to the Spool (2). The Spool (2) is seated in the lower Posipak Seal (6). 2. The dispe...
5 SETUP PROCEDURE MOUNTING DISPENSE VALVE Mounting holes are drilled through the valve body. The valve may be tilted to a maximum of 60 degrees from the vertical depending on the application. AIR CONTROLLER Operation of the Model 715 Dispense Valve requires a controller that can provide the followin...
6 OPERATING PROCEDURES WET CUP LOADING Some models are equipped with a wet cup around the Spool (2) to keep it wetted. This helps prevent curing or crystallization of material on the spool and consequent premature seal failure. Fill the wet cup with a compatible self-leveling material prior to opera...