- Page 2 – Warnings; WARNING; FIRE AND EXPLOSION HAZARD; Special Conditions for Safe Use; Read MSDSs to know the specific hazards of the fluids you are using.; PRESSURIZED EQUIPMENT HAZARD
- Page 3 – EQUIPMENT MISUSE HAZARD; PERSONAL PROTECTIVE EQUIPMENT
- Page 4 – Carefully unscrew lubrication canister from; Component Identification; Canister cannot be refilled.
- Page 5 – Installation and Setup; YES; Installation Guidelines
- Page 6 – Electronic Control Setup; Installing the Electronic Control Cover; Relieve pressure; Setting Up the Electronic Control; SET
- Page 7 – Preparing for Installation; Checking the Counter Pressure; Counter Pressure Test Procedure
- Page 8 – cc; no more than 5 seconds; Example; NOTICE
- Page 9 – Remote Mounting Installations; Direct Mounting
- Page 10 – With Tube and Grease; F Tube connection (User; With Tube and Oil; F Tube connection (user
- Page 11 – Turn the electronic control cover; Replacement Cansiters; Use a spanner wrench to separate battery; Storage; Application
- Page 12 – Troubleshooting; Malfunction
- Page 13 – Grease dispensing too slowly
- Page 14 – Dimensions
- Page 15 – Notes
- Page 16 – Graco Standard Warranty; Graco Information
Instructions
TC-130 Lubricators
3A1898B
EN
Electronically controlled, single point lubricator that provides lubrication to roller and slide
bearings, shaft seals and chains located in areas with considerable temperature variations
or where intrinsic safety is a requirement. For professional use only.
87 psi (0.6 MPa, 6 bar) Maximum Working Pressure
Intrinsically safe apparatus, suitable for installation in Class I, II and III, Division 1, Groups A, B, C,
D, E, F and G hazardous (classified) locations and Class I, Zone 1, AEx ia, IIC, and Class II, Zone
21, T-class is T4 at -20°C< Ta < +60°C.
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Lubricator
Part No.
Replacement
Canister
Application
24J98 1
24M684
Multi EP-2
24J98 2
24M685
Construction
24J98 3
24M686
Bearing
24J98 4
24M687
Milling
24J98 5
24M688
Food Grade H1
24J98 6
24M689
Synthetic Industrial
24J98 7
24M690
Ultra Spindle
24J98 8
24M691
Multi EP-1
I M1 Ex ia I Ma
II 2 G Ex ia IIC T4 Gb
II 2 D Ex ia IIIC T135°C Db
ZELM 11 ATEX 0468X
-20°C< Ta < +60°C
0359
EX ia I Ma
EX ia IIC T4 Gb
Ex ia IIIC T135°C Db
IECEx ZLM 11.0007 X
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 3A1898B Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equip-ment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer ...
3A1898B 3 EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment...
Component Identification 4 3A1898B Pressure Relief Procedure 1. Cover lubrication point (A) and lubricator (B) with a heavy rag to absorb any fluid that may leak out while loosening the lubricator. 2. Carefully unscrew lubrication canister from the lubrication point (A). A Lubrication PointB Lubrica...