Graco 312782D - User Manual
Graco 312782D – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Contents
- Page 3 – Installation; Connect the Air Lines
- Page 5 – System Pneumatic Schematic (used with ProMix 2KS)
- Page 6 – Operation; Settings and Adjustments; Maintenance; Clean the Dispense Valve Daily
- Page 7 – Troubleshooting; Repair; Disassembly
- Page 8 – Reassembly
- Page 9 – Parts
- Page 11 – Technical Data
- Page 12 – Graco Standard Warranty; Graco Information
312782D
EN
Instructions-Parts
Air Actuated
Dispense Valve
To dispense plural component fluids and solvents. For professional use only.
Part No. 15X303
High Pressure Dispense Valve
3000 psi (21 MPa, 207 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure
Part No. 15X304
Low Pressure Dispense Valve
300 psi (2.1 MPa, 21.0 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual. For complete
warnings and instructions see your proportioning system manual.
Hazard symbols refer to specific procedure risks. Save all instruc-
tions.
TI11663A
TI11581A
15X303 High Pressure Valve
15X304 Low Pressure Valve
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Graco
- Model
- 312782D
- Document type
- User Manual
- Language(s)
- English
- Pages
- 12
- File size
- 1.3 MB
- Format
Summary
Related Manuals 2 312782D Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Connect the Air Lines . . . . . . . . . . . . . . . . . . . . . 3 Connect the Fluid Lines . . . . . . . . . . . . ...
Installation 312782D 3 Installation F IG . 2 shows the dispense valves installed in an elec- tronic 2-component proportioning system. In this exam-ple, the dispense valves are used as dose valves for components A and B (DVA, DVB), an air purge valve (APV), and a solvent purge valve (SPV). F IG . 3 s...
Installation 312782D 5 System Pneumatic Schematic (used with ProMix 2KS) F IG . 3. System Pneumatic Schematic 3/8 AIR FILTER MANUAL DRAIN 5 MICRON WALL MOUNT ONLY FL USH AIR TO FL UID INLE T 1/4 TUBE TO M ANIFOLD 1/4 TUBE 4-WAY SOLENOID 12 VDC PURGE A VALVE DUMP A VALVE (OPTIONAL) 4-WAY SOLENOID 12 ...