Graco 309920D- User Manual

Graco 309920D

Graco 309920D– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – Installation
  • Page 3 – Shop Air Piping Layout; Minimum Pipe Size Recommendations; Compressor; any; Air Pressure Drop Through Hose, by hose length and ID
  • Page 4 – Operation; Coalescer Pressure Drop Indicator; Parts; WARNING; Membrane Air Dryer
  • Page 5 – How Membrane Air Dryer Works; Air Filter with Auto Drain 234402, Series B
  • Page 6 – Sales Offices: Minneapolis; Graco Standard Warranty; For the latest information about Graco products, visit
Loading the manual

309920D

EN

Instructions - Parts List

Membrane Air Drying
System

Model 234418, Series C

Maximum Working Pressure 160 psi (1.1 MPa,
11 bar)
Maximum Temperature 150° F (65° C)

Includes:

Important Safety Instructions

Read all warnings and instructions in this manual.
Save these instructions

Part No.

Series

Description

Air Inlet

npt(f)

Air

Outlet

npt(f)

Air Flow

Capacity

at 100 psi

(0.7 MPa, 7 bar)

Maximum

Operating

Pressure

234402

B

Stage 1 - Air Filter with auto drain
Removes water and contaminants down
to 3 microns.

1/2”

1/2”

100 CFM

175 psi

(1.2 MPa, 12 bar)

234397

B

Stage 2 - Coalescer with auto drain
Removes oil and sub-micronic particles
down to 1 micron.

1/2”

1/2”

83 CFM

175 psi

(1.2 MPa, 12 bar)

118560

A

Stage 3 - Membrane Air Dryer
Removes uncondensed moisture.

1/2”

1/2”

30 CFM

175 psi

(1.2 MPa, 12 bar)

234394

A

Self Relieving Air Regulator

3/8”

1/4”

100 CFM

160 psi

1.1 MPa, 11 bar)

288798

A

Shut-off Valve

175 psi

(1.2 MPa, 12 bar)

ti22159a

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installation

Installation 2 309920D Installation 1. Before installing air line components, blow out the pipe line to remove debris. Be sure air to the regula-tor is clean. Erratic operation or loss of regulation is usually caused by dirt in the regulator. 2. Install the Air Drying System as close as possible to ...

Page 3 - Shop Air Piping Layout; Minimum Pipe Size Recommendations; Compressor; any; Air Pressure Drop Through Hose, by hose length and ID

Shop Air Piping Layout 309920D 3 Minimum Pipe Size Recommendations Compressor Main Air Line Size Capacity Length Size 1-1/2 - 2 HP 6 - 9 CFM any 3/4” (19 mm) 3 - 5 HP 12 - 20 CFM Up to 200 ft. (61 m) 3/4” (19 mm) Over 200 ft. (61 m) 1” (25.4 mm)) 5 - 10 HP 20 - 40 CFM Up to 100 ft. (30.5) 3/4” (19 m...

Page 4 - Operation; Coalescer Pressure Drop Indicator; Parts; WARNING; Membrane Air Dryer

Operation 4 309920D Operation 1. Attach air hose(s) to air regulator outlet valve 289165. 2. Open main shut-off valve 288798. 3. Turn the T-hand adjusting screw in or out to adjust regulator to desired setting. 4. Open outlet valve 289165 to supply air to spray guns or tool. 5. With air flowing, rea...