Table of Contents:
- Page 2 – Table of Contents
- Page 3 – WARNING; SKIN INJECTION HAZARD; EQUIPMENT MISUSE HAZARD
- Page 4 – Installation; Dust and Foreign Matter; CAUTION
- Page 5 – Grounding
- Page 6 – Operation; Pressure Relief Procedure; Recommended Usage
- Page 7 – Maintenance
- Page 8 – Graphical Illustration of the Function Matrix
- Page 9 – Parts; Use Only Genuine Graco Parts and Accessories
- Page 10 – Dimensions
- Page 11 – Technical Data for Bare Meter
- Page 12 – 0 Series Meter Wiring Detail
- Page 13 – Notes
Coriolis Fluid Flow Meter
Instructions–Parts List
309234H
EN
Important Safety Instructions
Read all warnings and instructions in this manual and
in your proportioner manual. Save these instructions.
The meter and meter kit are intended for installation and use on a PrecisionMix II fluid
panel in non–hazardous environments only. If a Coriolis meter is installed on a
PrecisionMix II, the entire system is no longer approved for a hazardous environment.
Not approved for use in explosive atmospheres or hazardous locations.
For professional use only.
5000 psi (34 MPa, 345 bar) Maximum Working Pressure
Part No. 116158 Bare Meter
.01 to 0.5 gpm (40 to 2,000 cc/min.) Flow Range.
Part No. 244039 Meter Kit
Includes Part No. 116158 Bare Meter, mounting hardware, and fittings.
2300 psi (16 MPa, 160 bar) Maximum Working Pressure
Part No. 15D135 Bare Meter
.01 to 0.5 gpm (40 to 2,000 cc/min.) Flow Range.
Part No. 15D599 Meter Kit
Includes Part No. 15D135 Bare Meter, mounting hardware, and fittings.
TI0624a
II 2 G EEx de IIC
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 309234 Table of Contents Warnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts 9 . . ....
309234 3 WARNING SKIN INJECTION HAZARD Spray from leaks, or ruptured components can inject fluid into your body and cause extremely seriousinjury, including the need for amputation. Splashing fluid in the eyes or on the skin can also causeserious injury. Fluid injected into the skin might look like ...
4 309234 Installation WARNING FIRE, EXPLOSION, AND ELECTRICSHOCK HAZARDTo reduce the risk of fire, explosion, orelectric shock: All electrical equipment must only be installedby a qualified electrician. Understand and follow your local code andsafety regulations for hazardous location wiringof explo...