Page 2 - Table of Contents
2 309234 Table of Contents Warnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts 9 . . ....
Page 3 - WARNING; SKIN INJECTION HAZARD; EQUIPMENT MISUSE HAZARD
309234 3 WARNING SKIN INJECTION HAZARD Spray from leaks, or ruptured components can inject fluid into your body and cause extremely seriousinjury, including the need for amputation. Splashing fluid in the eyes or on the skin can also causeserious injury. Fluid injected into the skin might look like ...
Page 4 - Installation; Dust and Foreign Matter; CAUTION
4 309234 Installation WARNING FIRE, EXPLOSION, AND ELECTRICSHOCK HAZARDTo reduce the risk of fire, explosion, orelectric shock: All electrical equipment must only be installedby a qualified electrician. Understand and follow your local code andsafety regulations for hazardous location wiringof explo...
Page 5 - Grounding
309234 5 Installation Vertical Mounting When mounting on a vertical surface, the preferredfluid flow is upward through the meter. See Fig. 2. Thisallows solids to settle out and air to rise away from themetering tube. This also allows thorough draining ofthe meter during shutdown, to prevent fluid f...
Page 6 - Operation; Pressure Relief Procedure; Recommended Usage
6 309234 Operation Pressure Relief Procedure WARNING INJECTION HAZARDThe system pressure must be manually relieved toprevent the system from starting or spraying acci-dentally. Fluid under high pressure can be injectedthrough the skin and cause serious injury. Toreduce the risk of an injury from inj...
Page 7 - Maintenance
309234 7 Operation Using the ProMass 80A with a GracoPrecisionMix II System Generic Settings for Basic Installation with aPrecisionMix II System The function matrix is a two level construct: groupsand functions. The groups, being the highest level, are compromisedby multiple functions. In order to s...
Page 8 - Graphical Illustration of the Function Matrix
8 309234 Graphical Illustration of the Function Matrix The table below shows a display of the total set valuesavailable. The values in bold are the minimum requiredsetting for use with a Graco PrecisionMix II System. A C TU A L FREQ . ME A S URE FLUI D DE NS ITY COE F . C 1 V A L U E SI M. CURR. FA ...
Page 9 - Parts; Use Only Genuine Graco Parts and Accessories
309234 9 Parts Use Only Genuine Graco Parts and Accessories Part No. 244039 and 15D599Coriolis Meter Kit, for solvent-borne materials (0.8–2000 cps) Ref.No. Part No. Description Qty. 1 116158 METER, Coriolis; for solventand water-borne materialsthat cannot be handledthrough a gear meter(244039 only)...
Page 10 - Dimensions
10 309234 Dimensions TI0852A A B C D EF G H J K L M N P R S T Dia Four 0.26 in.(6.6 mm) holes Diameter (ANSI) Dia. A B C D E F G H 1/8 in. 0.138 in. (3.5 mm) 1.26 in. (32 mm) 7.88 in. (200 mm) 11.0 in. (279 mm) 8.23 in. (209 mm) 5.90 in. (150 mm) 6.89 in. (175 mm) 8.66 in. (220 mm) 12.3 in. (312 mm)...
Page 11 - Technical Data for Bare Meter
309234 11 Technical Data for Bare Meter Category Data Maximum WorkingFluid Pressure Model 116158: 5000 psi (34 MPa, 345 bar)Model 15D135: 2300 psi (16 MPa, 160 bar) Flow Range 0.01–0.5 gpm (40–2,000 cc/min) Fluid TemperatureRange 40–180 F (4–80 C) Maximum AmbientTemperature 180 F (80 C) Fluid Viscos...
Page 12 - 0 Series Meter Wiring Detail
12 309234 Wiring Diagram for PrecisionMix II and PrecisionMix II 3K TI0625a 2021 1082 1082 2021 1082 A–4251, B–4271, C–4291 60 Series Meter Wiring Detail TI0625a 2021 1082 1082 2021 1082 A–4251, B–4271, C–4291 80 Series Meter Wiring Detail
Page 13 - Notes