Table of Contents:

  • Page 2 – Models
  • Page 3 – Warnings; WARNING
  • Page 5 – Installation; Fluid supply container: follow local code.; Thermal Overload
  • Page 6 – Component Identification
  • Page 7 – Sprayers; Spray Guns
  • Page 8 – Operation; Pressure Relief Procedure; Trigger Lock; Pressure Control Knob Settings
  • Page 9 – Setup
  • Page 10 – Priming
  • Page 11 – Pump Check Valves; CAUTION
  • Page 12 – Installing Tip and Base; Unclogging Spray Tip
  • Page 13 – Tip Selection; Selecting Tip Hole Size; HINTS; Tip Hole
  • Page 14 – Tip Hole Size
  • Page 15 – Spraying Techniques; Adjusting Pressure
  • Page 16 – Triggering Gun; Shutdown and Cleaning; Pail Flushing
  • Page 17 – Power Flush
  • Page 19 – Cleaning InstaClean; Gun Fluid Filter
  • Page 20 – Storage; Short Term Storage
  • Page 21 – Stowing Sprayer
  • Page 22 – Troubleshooting; Problem
  • Page 26 – Maintenance and Service; Caring for Sprayer; Paint Hoses; Pump Packings
  • Page 27 – Technical Data
  • Page 28 – Graco Standard Warranty
Loading the manual

Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001

309225W

Operation

Airless Sprayers

- For portable spray applications of architectural paints and coatings -

(Specifications, page 2.)

US Patent 6,752,067
European Patent 1 208 287
Korean Patent 10-0668583

ti4309a

WLD

WLD

WLD

M

AGNUM

dx

M

AGNUM

XR7

M

AGNUM

XR5

M

AGNUM

XR9

Model 232735

Model 232740

Model 232750

Model 232745

IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions in this
manual. Save these instructions. See page
2 for model and series information including
dispense rate, recommended hose length,
guns, and maximum working pressure.

Use water based or mineral spirit-type material only.
Do not use materials having flash points lower than
70°F (21°C). For more information about your mate-
rial request MSDS from distributor or retailer.

Model 247328

Visit our website;
http://Magnum.Graco.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Models

Models 2 309225W Models Specifications This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops or other “factory”, or fixed locations. If you intend to use this equipment in this type of application, you must comply with NFPA 33 and OSHA re...

Page 3 - Warnings; WARNING

Warnings 309225W 3 Warnings The following are general warnings related to the setup, use, grounding, maintenance and repair of this equipment. Additional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appearing in the body of the manual refer to the...

Page 5 - Installation; Fluid supply container: follow local code.; Thermal Overload

Installation 309225W 5 Installation Grounding and Electric Requirements Sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for electrical current due to static build up or in the event of a short circuit. The 120 Vac spray-ers require a 120 ...