Page 2 - GE Energy; Copyright Notice; Trademark Notices
GE Energy Copyright Notice © 2006-2007, General Electric Company. All rights reserved. The information contained in this online publication is the exclusive property of General Electric Company, except as otherwise indicated. You may view, copy and print documents and graphics incorporated in this o...
Page 3 - Contents
GE Energy D400 Substation Data Manager User's Manual 3 Contents About this Document 5 Product Support 7 1 Before You Start 9 2 Installing the D400 19 3 Setting up Communication Cards 24 4 Connecting to Devices and Networks 44 5 Powering Up the D400 63 6 Configuring the D400 74 7 Servicing the D400 7...
Page 5 - About this Document; Purpose; Electrical utility applications; Additional Documentation; D400 Product Information
GE Energy D400 Substation Data Manager User's Manual 5 About this Document Purpose This manual provides information about installing, setting up, using and maintaining your D400 Substation Data Manager. This manual does not provide any procedures for configuring the software of the D400. Note that s...
Page 6 - How to Use this Guide; Microsoft; Bold; Italic
GE Energy 6 994-0089–1.00–2, General How to Use this Guide This guide describes how to install the D400 and get it up and running for the first time. Procedures are provided for all component options available for the D400. The components included in your D400 depend on what was ordered for your sub...
Page 7 - Product Support; Search Technical Support
GE Energy D400 Substation Data Manager User's Manual 7 Product Support If you need help with any aspect of your GE Energy product, you have a few options. Search Technical Support The GE Energy Web site provides fast access to technical information, such as manuals, release notes and knowledge base ...
Page 8 - not
GE Energy 8 994-0089–1.00–2, General Have the following information ready to give to Customer Service: • Ship to address (the address that the product is to be returned to) • Bill to address (the address that the invoice is to be sent to) • Contact name • Contact phone number • Contact fax number • ...
Page 9 - Before You Start; Safety precautions; Precautions; Never
GE Energy D400 Substation Data Manager User's Manual 9 1 Before You Start Before you begin installing and using the D400, review the information in this chapter, including the following topics: • Safety precautions • Product overview • Product specifications • Storage recommendations Read and thorou...
Page 10 - Warning Symbols; Symbol Meaning
GE Energy 10 994-0089–1.00–2, General • The successful operation of this equipment depends upon proper handling, installation, and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property. • All AC voltage and...
Page 11 - Regulatory Compliance Information; CE Mark Compliance; The D400 is rated as CISPR 11 Group 1 Class “A” equipment.; Warning; Reorient or relocate the receiving device; Restriction of Hazardous Substances (RoHS); RoHS Material Declaration Data Content by Assembly
GE Energy D400 Substation Data Manager User's Manual 11 1.2 Regulatory Compliance Information CE Mark Compliance The D400 is rated as CISPR 11 Group 1 Class “A” equipment. Note: To provide higher EMC immunity and maintain CE Mark compliance, the serial cables used for permanent RS-232 and RS-485 con...
Page 12 - Overview
GE Energy 12 994-0089–1.00–2, General GE Part # Description Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) 520-0209 D400 Glass Fiber Optic IO Assy X O O O O O 520-0210 D400 Plastic Fiber Optic IO Assy X O O O O O ...
Page 13 - Hardware Overview; User configurable security levels/access
GE Energy D400 Substation Data Manager User's Manual 13 The D400 can be configured “online” through a standard Web browser or “offline” through the Offline Configuration Manager (OCM) - Future. Hardware Overview The D400 is built on a flexible, high-performance, expandable platform powered by a 650 ...
Page 14 - Internal Mini SQLTM database for archival of SOE and alarm records
GE Energy 14 994-0089–1.00–2, General • Internal Mini SQL™ database for archival of SOE and alarm records • Built-in basic math/logic functions • IEC 61131-3 soft logic engine - Future • Event notification (e-mail) • Portable memory device plug-in • Dual CompactFlash cards for system and user storag...
Page 15 - Specifications; Appendix; System; Communications
GE Energy D400 Substation Data Manager User's Manual 15 1.4 Product Specifications The D400 adheres to the following system, communications, electrical, physical and environmental specifications. Additional Standards and Protection are listed in Appendix A - Standards & Protection . System Proce...
Page 17 - Electrical; Physical
GE Energy D400 Substation Data Manager User's Manual 17 Electrical AC-DC 100-240 VAC (±10 %) 127 VA maximum 100-300 VDC (±10 %) 135 W maximum Rated power supplies DC-DC 20-55 VDC (±10 %) 135 W maximum AC-DC 26.5 A peak (< 145 VAC / 205 VDC) AC-DC 40 A peak (< 264 VAC / 370 VDC) Peak inrush cur...
Page 18 - Environmental; Recommendations; Storage Conditions
GE Energy 18 994-0089–1.00–2, General Environmental Operating temperature -20 °C to +65 °C Maximum ambient temperature is +50 °C for unit to fully comply with IEC 61010-1 Section 10.1 regarding surface temperature limits for protection against burns. Humidity rating 5 % to 95 % relative humidity, no...
Page 19 - This chapter covers the following topics:; Steps; Follow these main steps to install and set up the D400:
GE Energy D400 Substation Data Manager User's Manual 19 2 Installing the D400 This chapter covers the following topics: • Overview of the steps and tools required to install the D400 • Tour of the product features • How to physically install the D400 in a rack or substation panel CAUTION: Before you...
Page 20 - Tools; Wire cutters
GE Energy 20 994-0089–1.00–2, General 2.2 Required Tools Before beginning the installation procedures, have the following tools and equipment available: • Ethernet cable(s) • Flathead screwdriver with 0.6 mm by 3.5 mm blade (for terminal block wiring) • Flathead screwdriver with 0.3 mm by 2.5 mm bla...
Page 21 - the; Shipping Inspection; report it immediately to the; Unpacking; report it immediately to the carrier; Package Contents; The following items are provided as part of your D400 shipment:
GE Energy D400 Substation Data Manager User's Manual 21 2.3 Unpacking the D400 Shipping Inspection Inspect the shipping package before opening it to see if it has sustained any damage from impact or water. If there are visible signs of damage, report it immediately to the carrier without opening the...
Page 22 - First Look at the D400; Front Panel
GE Energy 22 994-0089–1.00–2, General 2.4 First Look at the D400 Front Panel The front panel of the D400 provides easy access to the status indicators, user connections and power supply units. Power Supply Optional Redundant Power Supply D400 Main Module User CompactFlash access panel System StatusL...
Page 23 - Installation; Rack Mounting; Position the D400 in the rack.; Panel Mount
GE Energy D400 Substation Data Manager User's Manual 23 2.5 Physical Installation The D400 can be installed in a standard 19-inch rack or substation panel. Rack Mounting The D400 mounts directly into an industry-standard 19-inch [482.6 mm] equipment mounting rack with EIA universal mounting rail hol...
Page 24 - Setting up Communication; Cards; D400 I/O Adapter Card Slots
GE Energy D400 Substation Data Manager User's Manual 24 3 Setting up Communication Cards This chapter describes the D400 communication cards and how to change the card settings for the different configuration options. The communication cards are factory installed in the D400 with default settings. 3...
Page 25 - Types of Communication Cards; Hot Standby Fiber Optic Ethernet Switch
GE Energy D400 Substation Data Manager User's Manual 25 Types of Communication Cards The types of communication cards included in your D400 depend on what was ordered for your substation application. The following types of communication cards are available for the D400: Serial (Slots 1 to 8) • RS-23...
Page 26 - Changing Card Settings; To change the settings on a communication card:; card screws) to change switch positions.
GE Energy 26 994-0089–1.00–2, General 3.2 Changing Card Settings The communication cards are factory installed with default settings. You may want to adjust individual card settings to work with your specific system set up. The communication cards are hot swappable -- this means you do not have to p...
Page 27 - Adapter; Configuration Options
GE Energy D400 Substation Data Manager User's Manual 27 3.3 RS-232 Adapter The RS-232 Adapter (GE Part No. 520-0207) is a standard RS-232 serial I/O adapter card that plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-232 serial ports ...
Page 28 - RS-232 Adapter Top Side; Switch SW1/SW2 Configuration; Switches; *Use DTE or DCE settings as appropriate
GE Energy 28 994-0089–1.00–2, General RS-232 Adapter Top Side Switch SW1/SW2 Configuration Switches SW1 (for Port 2) and SW2 (for Port 1) control the signal type of the RS-232 port. Each switch contains five switch positions that can each be set to position A or B to select the appropriate port opti...
Page 29 - DCE; Switch SW3/SW4 Configuration; ON; or; OFF; Function
GE Energy D400 Substation Data Manager User's Manual 29 DTE (default) 1 2 3 4 5 A B DCE 1 2 3 4 5 A B Switch SW3/SW4 Configuration Switches SW3 (for Port 2) and SW4 (for Port 1) control the signals on Pins 4 and 6 of the RS-232 port. Each switch contains four switch positions that can each be set to...
Page 30 - DTE (Pin 4 DTR Output and Pin 6 DSR Input); DCE (Pin 4 DSR Input and Pin 6 DTR Output)
GE Energy 30 994-0089–1.00–2, General DTE (Pin 4 DTR Output and Pin 6 DSR Input) 1 2 3 ON 4 5 6 7 8 DCE (Pin 4 DSR Input and Pin 6 DTR Output) 1 2 3 ON 4 5 6 7 8 IRIG-B Enable (on Pin 4) and Ground (on Pin 6) 1 2 3 ON 4 5 6 7 8
Page 31 - on a single terminal block; to select the appropriate channel
GE Energy D400 Substation Data Manager User's Manual 31 3.4 RS-485 Adapter The RS-485 Adapter (GE Part No. 520-0208) plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-485 channels on a single terminal block TB1 : Channel 1 on terminal...
Page 32 - RS-485 Adapter Top Side
GE Energy 32 994-0089–1.00–2, General RS-485 Adapter Top Side RS-485 Adapter Bottom Side
Page 33 - to select the appropriate function for the switch.; SW3/SW4 Pin Pin Position Function
GE Energy D400 Substation Data Manager User's Manual 33 Switch SW3/SW4 Configuration Switches SW3 (for Channel 2 on TB1-6 through TB1-10) and SW4 (for Channel 1 on TB1-1 through TB1-5) contain ten DIP-switches that control pull-up and pull-down resistors for the differential data lines and provide l...
Page 34 - Fiber Optic Serial Adapter; Fiber Optic Serial Card Switch SW1 Settings
GE Energy 34 994-0089–1.00–2, General 3.5 Fiber Optic Serial Adapter The Fiber Optic Serial Adapter is available in two variants: • Glass Optical Fiber (GOF) Serial with 820-850 nm ST connectors (GE Part No. 520-0209) • Plastic Optical Fiber (POF) Serial with 660 nm Agilent Versatile Link connectors...
Page 35 - Glass Optical Fiber Serial Adapter
GE Energy D400 Substation Data Manager User's Manual 35 Glass Optical Fiber Serial Adapter Plastic Optical Fiber Serial Adapter
Page 36 - Input; BNC; IRIG-B Input Card Switch SW1 Settings
GE Energy 36 994-0089–1.00–2, General 3.6 IRIG-B Input Adapter The IRIG-B Input Adapter (GE Part No. 520-0211) plugs into a dedicated IRIG-B slot (slot 9) on the D400. The IRIG-B Input card accepts an IRIG-B signal in one of three input formats through a corresponding connector type: • Modulated IRI...
Page 37 - Switch SW2 Configuration; Switch SW3 Configuration
GE Energy D400 Substation Data Manager User's Manual 37 IRIG-B Input Adapter Switch SW2 Configuration Switch SW2 controls the signal option for the selected state option (SW1). It contains three switch positions that can be set to ON or OFF to select the appropriate signal. IRIG-B Input Card Switch ...
Page 38 - IRIG-B Distribution Adapter
GE Energy 38 994-0089–1.00–2, General 3.7 IRIG-B Distribution Adapter The IRIG-B Distribution Adapter (GE Part No. 520-0212) is an optional IRIG-B output card to supply an IRIG-B (TTL) signal passed from the IRIG-B Input card to attached IEDs. The IRIG-B Distribution card provides four channels on a...
Page 39 - -Port Twisted-Pair Ethernet Switch Card
GE Energy D400 Substation Data Manager User's Manual 39 3.8 4-Port Twisted-Pair Ethernet Switch The 4-Port Twisted-Pair Ethernet Switch (GE Part No. 520-0213) is a 10/100BaseT network switch that plugs into the NET1 or NET2 slot (slots 11 and 12) on the D400. It provides local area network connectio...
Page 40 - and; Hot Standby Fiber Optic Ethernet Switch Card
GE Energy 40 994-0089–1.00–2, General 3.9 Hot Standby Fiber Optic Ethernet Switch The Hot Standby Fiber Optic Ethernet Switch (GE Part No. 520-0214) is a 100BaseSX (820-850 nm) network switch that supports single-IP redundancy for the D400. It provides automated fail over between two Ethernet fiber ...
Page 41 - Redundant Twisted-Pair Ethernet + COM2 Port Adapter; LAN; input routes to a three-port Ethernet switch and the; WAN; input; Redundant TP Ethernet + COM2 Port Adapter Card
GE Energy D400 Substation Data Manager User's Manual 41 3.10 Redundant Twisted-Pair Ethernet + COM2 Port Adapter The Redundant TP Ethernet + COM2 Port card (GE Part No. 520-0218) provides two local area network connections with unique MAC addresses through Ethernet RJ-45 connectors. The LAN input ro...
Page 42 - Port; External modem; There are no selectable options on the COM2 Port card.
GE Energy 42 994-0089–1.00–2, General 3.11 COM2 Port Adapter The COM2 Port Adapter (GE Part No. 520-0219) provides a single DB-9 connector ( P2 ) wired for an RS-232 DCE signal. The COM2 Port card can support serial connections for the following dial-up interfaces: • External modem • Point-to-point ...
Page 43 - USB KVM & Audio Adapter; device; USB KVM Adapter
GE Energy D400 Substation Data Manager User's Manual 43 3.12 USB KVM & Audio Adapter The USB Keyboard, Video, Mouse Adapter (GE Part No. 520-0206) plugs into the USB KVM slot (slot 13) on the D400. The card provides connections for setting up a permanent local workstation, including: • Three USB...
Page 44 - Connecting to Devices and; Types; Serial; Protective relays
GE Energy 44 994-0089–1.00–2, General 4 Connecting to Devices and Networks This chapter provides guidelines for making physical connections between the D400 and substation and network devices. 4.1 Connection Types The D400 can accommodate a wide range of devices and network connections through a var...
Page 45 - Network; SCADA master station; Time Synchronization
GE Energy D400 Substation Data Manager User's Manual 45 The following types of serial connections are supported in single or multi-dropped set ups: • RS-232 • RS-485 (2-wire or 4-wire) • Fiber Optic Serial (glass or plastic) Network The D400 can support up to eight network connections to host and ne...
Page 46 - General Cabling Requirements
GE Energy 46 994-0089–1.00–2, General 4.2 Cabling Overview The D400 provides a series of I/O adapter cards for connecting cables and wiring from substation devices and network interfaces. All physical connections are made to easily accessible connectors on the rear panel of the D400. D400 Field and ...
Page 47 - High-Voltage Installations; ables must be shielded
GE Energy D400 Substation Data Manager User's Manual 47 High-Voltage Installations To provide higher EMC immunity and maintain CE Mark compliance, the serial cables used for permanent RS-232 and RS-485 connections must comply with the following requirements: • C ables must be shielded • D-type conne...
Page 48 - Connections; independently isolated RS-232 serial ports (; Relay
GE Energy 48 994-0089–1.00–2, General 4.3 RS-232 Connections The D400 accepts connections to RS-232 type devices through the RS-232 Adapter. The RS-232 Adapter (GE Part No. 520-0207) is a standard RS-232 serial I/O adapter card that plugs into any serial communication slot (slots 1 through 8) on the...
Page 49 - Cabling Requirements
GE Energy D400 Substation Data Manager User's Manual 49 4.4 RS-485 Connections The D400 accepts connections to RS-485 2-wire and 4-wire type devices through the RS-485 Adapter. The RS-485 Adapter (GE Part No. 520-0208) plugs into any serial communication slot (slots 1 through 8) on the D400. It cont...
Page 50 - RS-485 2-Wire Terminal Block Signal Definitions
GE Energy 50 994-0089–1.00–2, General RS-485 2-Wire Terminal Block Signal Definitions 2-Wire RS-485 Channel Position Number Function Signal Flow 1 TX1+ IN/OUT 2 TX1- IN/OUT 3 FGND 1 - 4 RX1- - Channel 1 5 RX1+ - 6 TX2+ IN/OUT 7 TX2- IN/OUT 8 FGND 2 - 9 RX2- - Channel 2 10 RX2+ - Note: The terminal b...
Page 51 - following wiring connection:
GE Energy D400 Substation Data Manager User's Manual 51 4-Wire Connections In 4-wire mode, the RS-485 Adapter supports a maximum of 32 transceivers per channel (64 devices per RS-485 Adapter card). See section “3.4 RS-485 Adapter” for configuration options. » To connect RS-485 4-wire type devices to...
Page 52 - RS-485 4-Wire Terminal Block Signal Definitions
GE Energy 52 994-0089–1.00–2, General RS-485 4-Wire Terminal Block Signal Definitions 4-Wire (default) RS-485 Channel Position Number Function Signal Flow 1 TX1+ OUT 2 TX1- OUT 3 FGND 1 - 4 RX1- IN Channel 1 5 RX1+ IN 6 TX2+ OUT 7 TX2- OUT 8 FGND 2 - 9 RX2- IN Channel 2 10 RX2+ IN Note: The terminal...
Page 53 - Fiber Optic Connections; Glass Optical Fiber; ST Connectors; Do not view directly with optical instruments; Plastic Optical Fiber; Plastic optical fiber transmitter power is –9.0 ± 4.5 dBm
GE Energy D400 Substation Data Manager User's Manual 53 4.5 Fiber Optic Connections For devices located some distance from the D400, they may be connected using glass or plastic optical fiber cables. Fiber optic cabling also offers superior performance in electrically noisy environments. Glass Optic...
Page 54 - into the corresponding TX and RX connectors.
GE Energy 54 994-0089–1.00–2, General Warning: LED transmitters are classified as IEC 60825-1 Accessible Emission Limit (AEL) Class 1M. Class 1M devices are considered eye safe to the unaided eye. Do not view directly with optical instruments . See section “3.5 Fiber Optic Serial Adapter” for config...
Page 55 - Fiber Optic Connector Signal Definitions; IRIG-B Input Adapter; Modulated IRIG-B through a BNC connector; TTL; ) through a terminal block; RX; Glass optical fiber transmitter power is –19.0 ± 2 dBm
GE Energy D400 Substation Data Manager User's Manual 55 Fiber Optic Connector Signal Definitions Connector Function TX1 Primary Fiber Optic Transmit Port RX1 Primary Fiber Optic Receive Port TX2 Hot Standby Secondary Fiber Optic Transmit Port RX2 Hot Standby Secondary Fiber Optic Receive Port See se...
Page 57 - Front Network Port
GE Energy D400 Substation Data Manager User's Manual 57 4.7 Network Connections The D400 supports a network interface through Ethernet connections to the 4-Port Twisted-Pair Ethernet Switch or Redundant Twisted-Pair Ethernet + COM2 Port Adapter. All RJ-45 connectors have the same signal definition. ...
Page 59 - To connect a modem to the COM2 Port Adapter, use a straight-through
GE Energy D400 Substation Data Manager User's Manual 59 4.8 Modem Connections A COM2 port is provided on the COM2 Port Adapter or the Redundant TP Ethernet + COM2 Port Adapter. The COM2 port can support serial connections for the following dial-up interfaces: • External modem • Point-to-point protoc...
Page 61 - Local HMI Connection; Single 3.5 mm audio jack for stereo audio output to speakers; To connect a local substation computer to the USB KVM Adapter:; Connect the monitor to the video port.
GE Energy D400 Substation Data Manager User's Manual 61 4.9 Local HMI Connection A permanent local workstation can be set up with the D400 to access the D400’s HMI (human machine interface). The computer peripherals connect to the USB KVM Adapter located on the rear panel of the D400. The D400 suppo...
Page 62 - Front Maintenance Port; Connecting to the D400 for; the First Time” for more information on; To connect your computer to the D400:; D400 Front Serial Port DB-9 Pin Out; Minimal Required Connection; Signal
GE Energy 62 994-0089–1.00–2, General 4.10 Front Maintenance Port The serial communications port on the front panel of the D400 provides a local connection with the D400 to perform the initial setup of the D400 and to carry out maintenance and diagnostic procedures. The front maintenance port provid...
Page 63 - Powering Up the D400; Power Supply Options
GE Energy D400 Substation Data Manager User's Manual 63 5 Powering Up the D400 This chapter describes the power supplies and how to make power connections. 5.1 Power Supply Options The D400 supports one or two power supplies that provide 5 V to the D400 main module. The following power supplies may ...
Page 64 - Redundant Power Supply; The D400 supports the following power configurations:; Power Input Ranges
GE Energy 64 994-0089–1.00–2, General Redundant Power Supply The D400 may be provided with an optional redundant power supply unit in Power Supply Slot 2. The second power supply provides continuous power to the D400 in the event the primary power supply unit fails. Additional protection can be prov...
Page 65 - Terminal block; Wiring Requirements
GE Energy D400 Substation Data Manager User's Manual 65 5.2 Power Connections The D400 accepts power connections through two terminal blocks on the rear panel: • Terminal block TB1 is reserved for connecting power from one or two external sources to the D400. • Terminal block TB2 provides contact cl...
Page 66 - External Power Requirements; Remove the terminal block
GE Energy 66 994-0089–1.00–2, General External Power Requirements Before connecting an external power source to the D400, ensure that the following external power requirements are met: • An IEC 61010 qualified primary disconnect device and over current protection not exceeding 15 A must be externall...
Page 67 - Supply 1; Supply 1; Supply 1
GE Energy D400 Substation Data Manager User's Manual 67 Power Source Configurations Power Source Connection Wiring Diagram Single External AC Power Source Connected to SUPPLY1 and SUPPLY2 input terminals. L N GND AC Power Source Supply 1 Supply 2 Single External DC Power Source Connected to SUPPLY1 ...
Page 68 - Power Source; Connect protective earth wire to the Protective Earth terminal
GE Energy 68 994-0089–1.00–2, General Power Source Connection Wiring Diagram Two External DC Power Sources with Optional Redundant D400 DC Power Converter First source connected to SUPPLY1 terminals. Second source connected to SUPPLY2 terminals. DC Power Source #1 DC Power Source #2 + - + - Supply 1...
Page 69 - Power Supply Alarms; Power Fail Alarm; To enable the indicator when power is...
GE Energy D400 Substation Data Manager User's Manual 69 5.3 Power Supply Alarms The D400 includes connections for two power supply alarms: • Power Fail to indicate one of the two power supplies or one of the two power feeds has failed • System Fail to indicate system operation status Terminal block ...
Page 70 - Power Fail Alarm Connection; System Fail
GE Energy 70 994-0089–1.00–2, General Power Fail Alarm Connection Station Battery / Power Source Light ON when operational Light ON after failure System Fail The D400 includes a System Fail contact closure to provide an external LED indication on the system or LAN status. The LED notification can be...
Page 71 - System Fail Alarm Connection
GE Energy D400 Substation Data Manager User's Manual 71 System Fail Alarm Connection Light ON when operational Light ON after failure Station Battery / Power Source
Page 72 - Front Panel LEDs; System Status LEDs; The System Status LEDs indicate the unit’s operational status:
GE Energy 72 994-0089–1.00–2, General 5.4 Front Panel LEDs Once the D400 is powered up, the LED indicators on the front panel of the D400 become active. The indicators provide status information on the operation of the D400. D400 Front LEDs System Status LEDs The System Status LEDs indicate the unit...
Page 73 - Serial Port Status LEDs; LED Display; RXD
GE Energy D400 Substation Data Manager User's Manual 73 Serial Port Status LEDs The Serial Port Status LEDs provide a visual indication of the status for each serial communication port. For a given serial communication port: LED Display Status Description TXD Serial transmission activity on the seri...
Page 74 - Conf iguring the D400; to; To connect to the D400:
GE Energy 74 994-0089–1.00–2, General 6 Conf iguring the D400 When you receive your D400, it is configured with default communication settings. To enable the D400 to communicate over your network, you must change the settings as required by your system. 6.1 Connecting to the D400 for the First Time ...
Page 76 - To configure the network interface:; Enter
GE Energy 76 994-0089–1.00–2, General You are now online with the D400. » To configure the network interface: 1. At the D400 #>> prompt, type D400cfg and press Enter . The D400 Configuration Utility menu appears. 2. Type 2 and press Enter to select 2. Configure Network Interface . The Network ...
Page 78 - D400 Software Configuration Guide
GE Energy 78 994-0089–1.00–2, General The default IP address is 192.168.168.81 . 6. Enter the Subnet Mask of the D400. The default Subnet Mask is 255.255.255.0 . 7. Enter the DNS Server address. If the DNS Server address is not required, press Enter to continue. 8. Enter the Gateway IP address. If t...
Page 80 - Removing the D400 Main Module; To remove and re-insert the D400 main module:; Power
GE Energy 80 994-0089–1.00–2, General 7.1 Removing the D400 Main Module You need to remove the D400 main module from the chassis to access the system battery and the system CompactFlash card for maintenance. D400 Main Module » To remove and re-insert the D400 main module: 1. Power down the D400. 2. ...
Page 81 - Replacing the Battery; chassis. The battery holder
GE Energy D400 Substation Data Manager User's Manual 81 7.2 Replacing the Battery The lithium battery maintains power to the D400's built-in Real-Time Clock and NVRAM if there is a power disconnect. The D400 is supplied with a 1/2AA 3.6 V 0.9 Ah Lithium battery that you must insert on the D400 main ...
Page 82 - Before You Remove the Battery...; Note the following items before you begin battery replacement.; CAUTION; Disconnect power to the D400 before changing the; Supported Battery Types; Supported battery replacements
GE Energy 82 994-0089–1.00–2, General Before You Remove the Battery… Note the following items before you begin battery replacement. CAUTION • Disconnect power to the D400 before changing the battery. • Avoid exposure to high temperatures, such as soldering or spot-welding • Avoid excessive force to ...
Page 84 - Changing the CompactFlash; User CompactFlash Access Panel; To change the System CompactFlash card:; To change the User CompactFlash card:; Eject
GE Energy 84 994-0089–1.00–2, General 7.3 Changing the CompactFlash CompactFlash cards are designed with flash technology, a non-volatile storage solution that can retain data indefinitely without a battery. The cards are solid state, meaning they contain no moving parts, and provide much greater pr...
Page 85 - Replacing the Power Supply; D400 Power Supply Unit; Before You Remove the Power Supply...; To replace a D400 power supply unit:
GE Energy D400 Substation Data Manager User's Manual 85 7.4 Replacing the Power Supply The power supply module is accessible and easily replaced from the D400 front panel. The D400 may be supplied with an optional redundant power supply (in Slot 2) to provide dual hot swappable power supplies. If th...
Page 86 - Standards & Protection; D400 Standards and Protection
GE Energy D400 Substation Data Manager User's Manual 86 A Standards & Protection This Appendix lists the standards with which the D400 has been tested for compliance. D400 Standards and Protection Category Standard Name Description EN55011 (CISPR 11) 1 ISM RF equipment – Electromagnetic disturba...
Page 87 - Category Standard
GE Energy D400 Substation Data Manager User's Manual 87 Category Standard Name Description IEC 61000-4-5 Surge immunity test IEC 61000-4-6 IEC 60255-22-6 Immunity to conducted disturbances, induced by radio-frequency fields IEC 60255-22-1 1 MHz burst immunity test IEC 61000-4-8 Power frequency magne...
Page 89 - Ordering Guide; Product Identification; configuration of the unit. This ID number is composed of
GE Energy D400 Substation Data Manager User's Manual 89 B Ordering Guide Product Identification The D400 comes with an ID number that identifies the supplied options and hardware configuration of the unit. This ID number is composed of 400- followed by 16 alphanumeric characters that are determined ...
Page 91 - Modification Record; Authentication Record
GE Energy D400 Substation Data Manager User's Manual 91 Modification Record Version Rev. Date Author Change Description 1.00 0 July 12, 2006 S. Tessari Document created. 1.00 1 Nov. 17, 2006 E. Stuhr S. Tessari Revisions as required by TUV. Deleted Supported Devices sections. Moved signal definition...