Page 2 - FCC Notices
FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix Inc. can void the user’s authority to operate the equipment. FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to ...
Page 3 - Canada Notice
Page 4 - Contents; Introduction to Your Security System
i Contents Introduction to Your Security System 1 Security System Components ..................................................................................................................... 1 How You Communicate to Your System 2 Control Panel .......................................................
Page 6 - Alarm System Limitations
iii Testing 24 Testing Sensors ......................................................................................................................................... 24Testing Communication ..............................................................................................................
Page 7 - Security System Components; Control Panel; Touchpads; Remote Handheld Touchpads; Sensors; Indoor Motion Sensors
Security Pro 1000 1 Introduction to Your Security System Your security system uses wireless technology to warn your family about intrusion, carbon monoxide and fire. It may also be used to control lights and appliances within your home. The system has the capabilities of communicating with a central...
Page 8 - Modules; Dialog RF Electronic Thermostat; * Not investigated for use by UL; Remote Handheld Touchpad
Security Pro 1000 2 Outdoor Motion Sensors detect motion in a protected outdoor area. When motion is detected, the system may respond by sounding chimes or turning on outside lights. These sensors are not used for intrusion detection. Door/Window Sensors detect the opening of a door or window. Smoke...
Page 9 - The panel interface consists of four rows of buttons.; HOME SECURITY; Arm
Security Pro 1000 3 How to Use Your Control Panel The panel interface consists of four rows of buttons. Note It may be necessary to enter an access code to arm your system. Check with your installer to see if this feature is enabled. • HOME SECURITY • CODE • HOME CONTROL • EMERGENCY HOME SECURITY Th...
Page 10 - Quick Exit; Latchkey; Arming Your System with Doors & Windows Closed; Arming Your System with No Entry Delay; Arm Motion Sensors; Activate Latchkey Feature
Security Pro 1000 4 Quick Exit Note The designated door may be opened and closed once. If you close the designated door behind you when you exit, you will have to disarm the system upon reentering. Leave the designated door open while using the Quick Exit feature. The Quick Exit feature is used when...
Page 11 - If You Never Leave After Arming; CODE; HOME CONTROL; have occurred. Leave immediately and call for help.
Security Pro 1000 5 ¾ Disarming Your System 1. Upon reentering your home the entry delay will begin. 2. Status beeps will sound. 3. Enter your access code using the Code buttons. Panel announces, System disarmed and the Disarm light will be lit . ¾ Subdisarm Your System 1. Enter your Master Access C...
Page 12 - Function not available; Chime Doors; Turn Chime Doors off:; Chime Special Motion; Direct Bypassing; Direct Unbypassing; Time Activated Lights; Turn Time Activated Lights on:
Security Pro 1000 6 pressed and a sensor or module is not associated (programmed) with this feature the panel will announce, Function not available . Chime Doors Chime Doors is used to signal (chime) when a protected door is opened while the sys-tem is disarmed. The panel will announce the door that...
Page 13 - Sensor Activated Lights; Turn Sensor Activated Lights On:; Controlling Individual Lights; Turn on individual lights that are controlled by Lamp Modules:; All Lights On; Turns on lights that are controlled by Lamp Modules:; All Lights Off; EMERGENCY
Security Pro 1000 7 Sensor Activated Lights Turn on designated lights (with Lamp Modules) when a sensor is tripped. You can pro-gram lockout times when Sensor Activated Lights won’t be active (see Programming Options 36 and 37). ¾ Turn Sensor Activated Lights On: 1. System must be disarmed. Press Se...
Page 14 - Panel Voice Messages; DISARM; Please enter your access code.”; CHIME; button when you have no motion sensors in your system.; Alarm Sirens and Lamp Modules; Status Beeps
Security Pro 1000 8 How Your System Communicates to You Your system responds to you through the use of panel voice messages, status beeps, alarms, panel indicator lights, and to a numeric pager if programmed. Panel Voice Messages When you press the buttons on the panel or the touchpads, the panel re...
Page 15 - Panel Indicator Lights; Use the following table to understand the panel indicator lights.; Numeric Pager; Alarm Siren and X10 Light Information
Security Pro 1000 9 Panel Indicator Lights Use the following table to understand the panel indicator lights. Numeric Pager You may program your security system to send a numeric message indicating system activities to your pager. The system will send the message twice. See “Programming Instructions”...
Page 16 - How to gain access to the Control Panel:; Phone Commands; Panel Function
Security Pro 1000 10 Canceling and Preventing Accidental Alarms One of the biggest concerns you might have regarding your security system, is causing an accidental alarm. Most accidental alarms occur when leaving the residence after arming the system, or, before disarming the system upon your return...
Page 17 - System Status; ARM Motion Sensors; Disarm; Subdisarm; Disarm; System Status
Security Pro 1000 11 If you are interactive with your panel and the panel hangs up on you, the system is calling in a report to the central monitoring station or a pager, due to an action made by you or someone at the security system site. How to Use Your Touchpads Touchpads are used to control the ...
Page 18 - Lights; Emergency; Keychain Touchpad; options are programmed
Security Pro 1000 12 Lights ¾ Turn on individual lights that are controlled by Lamp Modules: 1. Press Lights On button once. 2. Press the number of the lamp module you want to turn on. Panel will announce, light <number> on. ¾ Turn off individual lights that are controlled by Lamp Modules: 1. ...
Page 19 - Both Option 81 and 82 can be turned on at the same time.; START MENU; Programming Instructions; System must be disarmed.; Open the Panel Cover; by pressing the plastic latch on
Security Pro 1000 13 • Both Option 81 and 82 can be turned on at the same time. • Thermostat has to be in Auto Mode for Options 81 and 82 to work correctly. • When the panel is disarmed the thermostat returns to normal operating mode. Programming Your System The programming decals are visible when y...
Page 20 - Enter the Master Access Code; Access Codes; Version 3; Instruction
Security Pro 1000 14 Note The Master access code is 1-2-3-4 when the panel is shipped. You should change your Master Access Code after your system is installed (see “Access Code”). 2. Enter the Master Access Code . 3. The system voice will prompt you to begin with the START MENU . The START MENU inc...
Page 21 - How to change an Access Code:; Light Control; House Code; Delete Access Code
Security Pro 1000 15 Note Codes are always needed to disarm the system. Depend-ing on the panel configura-tion, codes may be needed to arm the system. Check with the installer for your system configuration. Your system may be set up so that the master code or an access code is required when arming. ...
Page 22 - Unit Number; How to set time for light control:; Programming Options; Add; On
Security Pro 1000 16 Unit Number Refers to a specific light within a house code. ¾ How to set time for light control: 1. Open the cover of the panel. 2. The panel voice prompts you to Use numbered keys to enter ID. Enter your mas- ter access code using the numbered keys. 3. The panel voice prompts y...
Page 23 - Option 03 - Latchkey Time
Security Pro 1000 17 Option 01 - Status Beeps Add this option to enable panel beeps. Status beeps are any beeps (including chime beeps) that come from the panel. See “Status Beeps”. 1. Open panel cover. Panel announces, Use numbered keys to enter ID. 2. Enter Access Code using the numbered keys. Pan...
Page 26 - Option 43 - Pager Phone Number; The panel will call the pager to indicate the following:
Security Pro 1000 20 2. Enter Access Code using the numbered keys. Panel announces, Please select from Start Menu. 3. Press Delete from the Start menu. Panel announces, Select from main menu 4. Press Option # . Panel announces, Option 1, press again for next option or done to select. 5. Press 42. Pa...
Page 28 - Option 82: Cooling Set Point; Trouble Beeps; AC Power Failure; Silencing Trouble Beeps; To stop the trouble beeps, press the; SYSTEM STATUS
Security Pro 1000 22 4. Press Option # . Panel announces, Option 1, press again for next option or done to select. 5. Press 81. Panel announces, Option 81, press again for next option or done to delete. 6. Press DONE . Panel announces, Option 81 deleted. Option 82: Cooling Set Point When this option...
Page 30 - System Access Alarm; Testing; Testing Sensors; Test; Sensor; Sensor test; Press DONE; Sensor test ok; press; Sensor test canceled or failure; Clearing System Status
Security Pro 1000 24 System Access Alarm The panel cover was opened while the system was armed. The system will call the cen-tral monitoring station to report a tamper alarm. Testing As an added safeguard, there are system tests you should do yourself on a regular basis. It is recommended that you t...
Page 31 - Testing Communication; To perform a phone test:; Setting the Clock; Shock Sensor; Device
Security Pro 1000 25 Testing Communication Communication between your system, the central monitoring station and your pager should be tested at least once per week to make sure you have the proper telephone connection. ¾ To perform a phone test: 1. Open the panel cover. 2. Enter the master access co...
Page 32 - Service; Emergency Planning; Understand how to use your security system
Security Pro 1000 26 • If sirens are not placed within hearing range of persons sleeping, in remote parts of the premises, or if they are placed behind doors or other obstacles. • If intruders gain access through unprotected points of entry or areas where sensors have been bypassed. • If intruders h...
Page 33 - Your Floor Plan
Security Pro 1000 27 • Escape fast! (Do not stop to pack.) • Use a different escape route if closed doors feel hot to the touch. • Crawl and hold your breath as much as possible to help reduce smoke inhalation during your escape. • Meet at a designated outdoor location. • Emphasize that no one shoul...
Page 35 - Sensor Locations; Sensor Number; X10 Module Locations; Location; Delay Times
Security Pro 1000 29 Access Codes Master Access Code:______________________ Access Code 1:__________________________ Access Code 2:__________________________ Access Code 3:__________________________ Access Code 4:__________________________ Access Code 5:__________________________ Sensor Locations Se...
Page 36 - Quick Reference Table; How to ...
How to … Control Panel Remote Handheld Touchpad Key Chain Touchpad Remote Phone Disarm theSystem Subdisarm theSystem Arm Only - Doors& Windows Arm Only –Motion Sensors Arm Doors,Windows &Motion Sensors Activate No EntryDelay Activate LatchkeyFeature Activate a PanicAlarm Check the SystemStat...