GE 5500 - Manual

GE 5500

GE 5500 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 2 – Quick Reference; 500 Series Cooling with Electric Heat; Control Panel; 500 Series Heat Pump with Backup Resistance Heat
  • Page 3 – 500 Series Heat Pump with Backup Resistance Heat; Zoneline; Example
  • Page 5 – Table of Contents; Features and Benefits; Important Notice
  • Page 6 – Introduction; Advantages of the GE Zoneline
  • Page 7 – Components of the Zoneline; Room Cabinet; Deluxe Series shown; Typical Installation; Optional Accessories of the Zoneline; Duct Adapter; Chaseway
  • Page 9 – 500 Series have universal heater
  • Page 10 – Cooling Temperature Limits
  • Page 11 – - A door with a lock, that replaces the standard
  • Page 12 – Auxiliar y Control Switches; Switches
  • Page 14 – Central Desk Control; No exter nal voltage may be applied to the unit through; NOT PERMITTED
  • Page 15 – Remote Thermostat Control; Resistance Heat Models; Freeze Sentinel
  • Page 16 – RAK806 Universal Control Cover Label; - solid state digital manual
  • Page 17 – See RAK806 Universal Control cover Label on page 15.
  • Page 20 – • Heat Pump Operation - Zoneline 5500 Series; Heat pump defrost - Zoneline 5500 Series; The microprocessor; Heat pump condensate; See page 34 for information on; Zoneline 5500 Series Heat Source Logic
  • Page 21 – Application Comments; : If an air conditioner is undersized (cooling; Air Distribution; All room cabinets return air through the front of the unit.
  • Page 22 – Dimensions
  • Page 23 – Wall Case
  • Page 24 – Wall Case Installation Data; General; Window, Curtain and Panel Wall Construction
  • Page 26 – ASTENING W; Figure 1
  • Page 27 – Cord Set Connected
  • Page 34 – Condensate Disposal Systems; All Zoneline Series; Packaged Terminal Air Conditioners and
  • Page 35 – ALL CASE WITH RAD10 DRAIN KIT
  • Page 37 – Components; Duct Extension RAK601; Slope-Front Discharge Units
  • Page 38 – DUCTED APPLICA
  • Page 39 – DUCTED DET; Line Cord Installation
  • Page 40 – Exterior Grilles; If an existing grille is not
  • Page 42 – is accomplished by ordering the
  • Page 43 – Permanent Connection Kits; are available for 265 volt; All wiring, including installation of receptacle, must; Replacement of Existing Chassis; Line Cord Connected Units; existing sub-base is the full width of the wall case,; If the; existing sub-base is not the full width of the wall case
  • Page 44 – Covers all model versions.
  • Page 45 – Capacities and COP at Various Outdoor Temperatures
  • Page 46 – Latent System Capacity; The total capacity of an air conditioner is made up of the; Sensible; capacity, the output of the unit used to remove heat; Latent
  • Page 47 – Normal Yearly Operating Data; Formula for Calculating Operating Costs Using Above Data:
  • Page 48 – Typical 2500 Series Wiring Diagram
  • Page 49 – Typical 3500 Series Wiring Diagram
  • Page 50 – Typical 5500 Series Wiring Diagram
  • Page 51 – Chassis
  • Page 54 – Heater Table
  • Page 55 – Power Connection Kits are; Power Connection Kits; 65 Volt
  • Page 56 – Complete Accessor y List
  • Page 58 – Ducted Installation Comments; New Installations
  • Page 59 – Alphabetical Index; Categor y
  • Page 60 – WHAT IS COVERED; FULL ONE-YEAR WARRANTY; GE Appliances
Loading the manual

Architects and Engineers

Design Data Manual

Featuring The NEW 5500 Series

Z O N E L I N E

®

P A C K A G E D T E R M I N A L A I R C O N D I T I O N E R S

We bring good things to life.

1719 Data Manual 2001 2/14/02 3:11 PM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
GE
Model
5500
Document type
Manual
Language(s)
English
Pages
60
File size
1.5 MB
Format
PDF

Summary

Page 2 - Quick Reference; 500 Series Cooling with Electric Heat; Control Panel; 500 Series Heat Pump with Backup Resistance Heat

2 Quick Reference 2500 Series Cooling with Electric Heat MODEL COOLING Cooling Electric Heat Electric Electric Min. Circuit NUMBER (Btuh) Watts EER (Btuh) Heater Heat Protection Watts Amps (Amps) AZ25E07D2* 7100/6900 600/585 11.8/11.8 8600/7100 2550/2090 11.0/10.0 15 AZ25E07D3* 7100/6900 600/585 11....

Page 3 - 500 Series Heat Pump with Backup Resistance Heat; Zoneline; Example

3 LEGEND COP – Coefficient of Performance EER – Energy Efficient Ratio * – Covers All Model Versions Quick Reference 5500 Series Control Panel 5500 Series Heat Pump with Backup Resistance Heat MODEL COOLING Voltage Cooling Reverse NUMBER (Btuh) 60 hz Watts EER COP Cycle Heat 1-phase (Btuh) AZ55H07DA...

Page 5 - Table of Contents; Features and Benefits; Important Notice

5 Table of Contents Front Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Mini-Specs 2500 and 3500 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....