Page 2 - Welcome; They are on a label; It contains; Save time and money.; Check the
Welcome to the GE family. We’reproud of our quality products andwe believe in dependable service.You’ll see it in this easy-to-use manual and you’ll hear it in thefriendly voices of our customer service department. Best of all, you’ll experience these values each time you enjoythe comfort of your Zo...
Page 3 - We strongly recommend; SAVE THESE INSTRUCTIONS; IMPORTANT SAFETY INFORMATION
• This Zoneline must be properlyinstalled in accordance with theInstallation Instructions before itis used. • Repair or replace immediatelyall electric service cords that havebecome frayed or otherwisedamaged. • Unplug or disconnect theZoneline at the fuse box or circuit breaker before making any re...
Page 4 - MODE; COOL FAN HEAT
COOL —For cooling HEAT —For heating FAN —For fan-only operation The fan control sets the fan operation for HIGH, LOW or AUTO speed. When set at AUTO , it auto- matically switches between LOW and HIGH as room temperature changes. The temp control is used to maintain theroom temperature. The compresso...
Page 5 - Energy Tips; CLOSE; , only the air inside the room; OPEN; Ventilation Control
5 Energy Tips Keep the vent control at CLOSE . The room air will be filtered andcirculated. Set the FAN at AUTO . It switches between low and high to adjustfor room temperature changes. Adjust the air louvers as shown toget the most hot or cool air intothe room. The ventilation control lever is loca...
Page 6 - Operating Instructions; Other Zoneline features; Pull out at the bottom to; About Your Heat Pump
Operating Instructions Other Zoneline features Additional controls are locatedbehind the room cabinet. To remove: Pull out at the bottom to release it from the tabs. Then lift up. To replace: Place the tabs over the top rail. Push inward at the bottom until it snaps into place. To Remove theRoom Cab...
Page 7 - F. It will turn the heater off; Freeze Sentinel
The Freeze Sentinel featureautomatically turns on the resistance heater and fan if theroom temperature (sensed at the unit) drops to approximately40 ° F. It will turn the heater off when the temperature reachesabout 45 ° F. The Freeze Sentinel helps preventplumbing damage in the room dueto sub-freez...
Page 8 - Outdoor Coils
8 Operating Instructions Care & Cleaning Turn the Zoneline off and discon-nect the power supply. To clean, use water and a milddetergent. Do not use bleach orabrasives. Room Cabinet and Case The coils on the outdoor side ofthe Zoneline should be checkedregularly. If they are clogged withdirt or ...
Page 9 - Decrease cost of operation.; To clean the air filters:; Vacuum off the heavy soil.; To remove the air filters:; Air Filters
Turn the Zoneline off before cleaning. The most important thing you cando to maintain the Zoneline is toclean the filter at least every 30days. Clogged filters reduce cool-ing, heating and air flow. Keeping these filters clean will: • Decrease cost of operation. • Save energy. • Prevent clogged heat...
Page 10 - Installation Instructions; Read carefully; Use the correct wall case.
10 Installation Instructions Read carefully If you have any questions, call the GE Answer Center at800.626.2000. • Use the correct wall case. This chassis is designed to beinstalled in an insulated wall case.This minimizes condensation fromforming on the room side of thecase. If the current wall cas...
Page 11 - Important Notes; Important electrical safety—read carefully; Zoneline Components
• Follow the National Electrical Code (NEC) or local codes andordinances. • For personal safety, this Zonelinemust be properly grounded. • Protective devices (fuses or circuitbreakers) acceptable for Zonelineinstallations are specified on thenameplate of each unit. CAUTION: • Do not use an extension...
Page 12 - OR; trade-size electrical
12 Installation Instructions A power connection kit must beused to supply power to theZoneline unit. The appropriate kitis determined by the voltage, themeans of electrical connection andthe amperage of the branch circuit.Connections of 208 or 230 voltcircuits may be with a universalpower cord kit o...
Page 13 - Insulated Wall Case
13 1 The RAB71 or RAB77 wall casemust be properly installed perinstructions packed with the case. 2 Remove the corrugated stiffenerand the outdoor protectivepanel. Use the slit in the out-door panel as a handhold andpush out. 3 Install the exterior grille fromthe room side following instruc-tions pa...
Page 15 - Low Voltage Connectors & Auxiliary Controls; the heat; Boost Heat Option; Electric Heat Option
Low Voltage Connectors & Auxiliary Controls The Boost Heat Option increasesthe Zoneline air temperature byadding electric heat to supplementthe heat pump. It automaticallyturns on when the outside tempera-ture is between 25 ° F. and 45 ° F. To set the Boost Heat Option, moveswitch 8 to the ON (u...
Page 17 - OFF; Central Desk Control
The Zoneline can be connected to a switch at the front desk thatallows you to turn the unit on or off without going to each unit.When the front desk switch is openthe Zoneline is on. Turn the switchto closed to turn it off. For load shedding, the CDC auxiliary switch 9 must be in the OFF (down) posi...
Page 18 - Temperature Limiting; Diagnosis Switch
18 Installation Instructions Temperature limiting can reduceenergy costs by limiting the lowesttemperature that can be set oncooling and the highest tempera-ture that can be set on heating.Temperature limiting is controlledby setting the first six auxiliaryswitches.The first three are used to select...
Page 19 - Helpful Information; Things that are normal; Noise; Dela; “CLICK”
19 Helpful Information Things that are normal Noise Explanation 3-Minute Dela y You may hear a pinging or popping noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps removemoisture and improve efficiency. You ma...
Page 20 - If Something Goes Wrong; Before you call for service
20 ZonelineDoesn’t Start Zoneline Does NotCool or Heat as itShould The unit is unplugged • Make sure the Zoneline plug is pushed completely into the outlet. The fuse is blown/circuit • Check the house fuse/circuit breaker breaker is tripped box and replace fuse or reset the breaker. The unit is wait...
Page 22 - Notes
Page 23 - TDD; GE Service Numbers; GE Answer Center; contact the people who ser-; Further Service
800.626.2000 TDD 800-833-4322 GE Service Numbers We’ll be there! Open 24 hours a day,7 days a week. GE Answer Center ® 800-GE-CARES (800-432-2737) We provide expert repair service,scheduled at a time that’sconvenient for you. Our factory-trained techniciansknow your air conditioner inside andout—so ...
Page 24 - What is Covered
What is Not Covered FULL ONE-YEAR WARRANTY For one year from date of original purchase, we will provide, free of charge, parts and on- site service labor to repair or replace any part of the room air conditioner that fails because of a manufacturing defect. FULL FIVE-YEAR WARRANTY For five years fro...