Page 2 - GE Consumer & Industrial SA
Model: 3-ph SNMP/Web plug-in adapter 1-ph SNMP/Web plug-in adapter SP SNMP/Web plug-in adapter 1-ph SNMP/Web external adapter Date of issue: 13.05.2008 File name: ISG_CNT_SNM_BAS_CRD_V012 Revision: 1.2 Identification No. P/N 1018959 P/N 1019070 P/N 23954 P/N 1019071 Up-dating Revision Concerns Date ...
Page 3 - Dear Customer; our very valued customers at; GE Digital Energy
Dear Customer , We thank you for selecting our products and are pleased to count you amongst our very valued customers at GE . We trust that the use of the SNMP/Web adapters for our Uninterruptible Power Supply systems, developed and produced to the highest standards of quality, will give you comple...
Page 4 - Table of contents; Page; ACCESS
Table of contents Page 1 SAFETY RULES ................................................................................................................................................. 5 1.1 WARNINGS AND CAUTIONS ...........................................................................................
Page 5 - SAFETY RULES; the warning contained in this manual are; THE ONLY CONDITION; GE; assumes no responsibility or; GE
1 SAFETY RULES With this document, GE gives to the user all the necessary information about the correct installation of the SNMP/Web adapters. Please read carefully this Installation Manual before installing or operating the adapters. We recommend that this manual be kept next to the UPS for future ...
Page 6 - WARNINGS AND CAUTIONS; GENERAL; Always strictly observe the “; STORAGE; Switching OFF the unit does not isolate the UPS from the mains.; BATTERY; Never dispose of battery in a fire: they may explode.
1.1 WARNINGS AND CAUTIONS GENERAL • Always strictly observe the “ UPS Safety Rules ” • Check carefully the integrity of the equipment. In case you note some visible damage, do not install the equipment but contact the nearest Service Centre . • WARNING: RISK OF ELECTRICAL SHOCK. Do not remove any UP...
Page 7 - ENVIRONMENT
ENVIRONMENT • Please take care of packaging material: either save it for later use or recycle/dispose in compliance with local and other applicable regulations. • The SNMP/Web adapters contain a removable, Lithium coin-cell battery. Dispose of used batteries in compliance with local and other applic...
Page 8 - EMC COMPATIBILITY; Reorient or relocate the receiving antenna
1.2 EMC COMPATIBILITY 1-ph SNMP/Web plug-in adapter (P/N 1019070) 1-ph SNMP/Web external adapter (P/N 1019071) This device has been tested for compliance with the following standards: • EN 61000-6-2 • EN 61000-6-3 NOTE: This equipment has been tested and found to comply with the limits for a Class B...
Page 9 - INTRODUCTION; CHECKING PACKAGE CONTENTS
2 INTRODUCTION 2.1 CHECKING PACKAGE CONTENTS The SNMP/Web adapters are delivered in different kits according to the model. 3-ph SNMP/Web plug-in adapter (P/N 1018959) • 3-ph SNMP/Web plug-in adapter, with pre-installed standard front panel • A front panel designed for LP33 Series UPSs • Square plate...
Page 10 - Third Party License ReadMe; specific
• Third Party License ReadMe • CD-ROM AC adapter Serial cable 2.2 OVERVIEW 3-ph SNMP/Web plug-in adapter (P/N 1018959) LP 33 Series UPS SitePro / SG Series UPS Reset RS-232 UTP 10/100 Active LAN UPS Reset RS-232 UTP 10/100 Active LAN UPS Reset RS-232 UTP 10/100 Active LAN UPS Reset RS-232 UTP 10/100...
Page 12 - ARCHITECTURE DIAGRAM; Linux
LEDs The various front panel LEDs have the following meaning: • LAN / Netlink Status Meaning Off No LAN connection detected LAN connection established, no communication On LAN connection established, receive or transmit active Blink • UPS / Fail Status Meaning OK / No Fault Off No UPS Connection On ...
Page 13 - ADDITIONAL DOCUMENTS; Installation Manual
2.5 ADDITIONAL DOCUMENTS The SNMP/Web adapter is provided with a CD-ROM containing the following documentation: • Installation Manual • Operating Manual • SNMP Management Information Base (MIB) • Release notes and other instructions, as applicable Modifications reserved Page 13/24 ISG_CNT_SNM_BAS_CR...
Page 14 - INSTALLATION; Strictly observe the ‘; UPS Safety Rules; Read carefully the UPS ‘; Operating Manual & Installation; ’ before installing or operating the equipment.; Service Centre; SitePro customers only; Logical Address; SNMP Card
3 INSTALLATION NOTE ! Strictly observe the ‘ UPS Safety Rules ’. Read carefully the UPS ‘ Operating Manual & Installation Guide ’ before installing or operating the equipment. If any problems are encountered with the installation procedure here described, please contact the nearest Service Centr...
Page 15 - Installing the SNMP Card in option slot; Install procedure for; Take care the plate does not fall inside the UPS!; SNMP adapter; Install procedure; for SitePro; Connectivity box
Modifications reserved Page 15/24 ISG_CNT_SNM_BAS_CRD_1GB_V012.doc Installation Guide SNMP/Web Adapter 3.1.2 Installing the SNMP Card in option slot IMPORTANT: Switch off the UPS, and wait approx. 2 minutes or switch the UPS to the manual bypass. In the latter case, please ensure that the mains inpu...
Page 16 - for SG Series
Install procedure for SG Series SG T 5 00 0 _ 0 5 0- 080_U PS_G E _03 Q1 OFF ON Q2 ON OFF 1. Change the front plate with the smaller one delivered with the Kit. 2. Insert the SNMP adapter in the options slot. 3. Fix the front plate of the SNMP adapter to the connectivity box, using the screw include...
Page 18 - The DB9 and RJ11 port share the same GND signal.
• Connect the power to the box (left-most connector in the picture above). Make sure that the SNMP/WEB Interface box is powered by the UPS output! • The UPS / Fail LED will switch OFF once the connection to the UPS is established. If the LED remains continuously on, check the UPS connection and rela...
Page 19 - CONFIGURATION; CONFIGURATION METHODS; Configuration via serial connection
4 CONFIGURATION 4.1 CONFIGURATION METHODS The SNMP/Web plug-in adapters can be configured using different interfaces. 4.1.1 Configuration via serial connection • Connect the SNMP adapter to a computer using a standard 1:1 serial communication cable. • Run a terminal simulator (e.g. HyperTerminal on ...
Page 20 - TELNET; NOTE
NOTE : Although the console interface provides a full set of commands, access using the serial connection is only needed for initial configuration when no DHCP server is available, or the IP-address is unknown. The quick network configuration menu provides a simple interface for basic network config...
Page 21 - NETWORK PARAMETERS; IP address; reboot; FURTHER INFORMATION; Operating Manual
4.2 NETWORK PARAMETERS The SNMP/Web adapter connects to the network using the following parameters: • IP address identifies the adapter on the network. • Subnet mask defines a range of addresses within the organisation. • Gateway the node used for connection to addresses outside the subnet. The adap...
Page 22 - ACCESS; TROUBLESHOOTING
5 ACCESS 5.1 WEB INTERFACE After the installation and configuration of the SNMP/Web adapter, the connection can be tested with a web browser. • Launch the browser • Enter the URL of the SNMP/Web adapter: http://<IP>/ (e.g. http://192.168.24.14/) • When prompted, enter username and password (by...
Page 23 - CUSTOMER SUPPORT; FIRST LINE SUPPORT; We have a WWW server running at
6 CUSTOMER SUPPORT 6.1 FIRST LINE SUPPORT Please contact your local GE distributor for problems with the installation of the product or its use. 6.2 INTERNET On-line support available on request (Internet access required). 6.3 WWW SERVER We have a WWW server running at www.gedigitalenergy.com With y...
Page 24 - APPENDIX A; SitePro EARTH CONNECTION; Note
7 APPENDIX A SitePro EARTH CONNECTION In order to guarantee correct functional behaviour, the SNMP/Web plug-in adapter must be connected to protective earth (UPS chassis). On SitePro UPSs manufactured before 2003 the square plates (delivered with the 3-ph adapter kit) must be mounted – refer to the ...