Page 4 - SAFETY INSTRUCTIONS; In case of EMERGENCY:; Press the “EMERGENCY” button when; B. Call for service if the error; STOP
SAFETY INSTRUCTIONS CAUTION: PF-3200 hasimplemented secondarythermostat to prevent the gluetank temperature from going over 392°F (200°C). When it occurs, thepower of PF-3200 will be automaticallyturned off. You have to wait for the gluetank to cool down before you canrestart the machine. If this pr...
Page 5 - Model; SPECIFICATIONS; Name; ACCESSORIES; NIPPING PRESSURE CONTROL
5 Model PF-3200 Perfect Binder Maximum Book Size 12.6" x 15.75" (320mm x 400mm) Minimum Book Size 3.15" x 1.97" (80mm x 50mm) Maximum Binding Thickness 1.6" (40mm) Glue Warm Up 25 minutes (varies depending upon glue type) Glue Warm Up in Stand-by Mode 5 minutes Cycle Speed 360 cy...
Page 6 - INSTALLATION; The procedures for installation:
6 INSTALLATION Note: You must remove the three redshipping brackets before installingyour PF-3200. The procedures for installation: Step 1: Remove the red shipping bracketlocated on the left side of the clampstation as shown. Then reinstall thescrews in clamp station. Step 2: Remove two red shipping...
Page 7 - CONTROL PANEL
7 No. Symbol Function LED Display / Symbol Example 1 EMERGENCY 2 STAND BY / LED 3 CLOSE 4 LED DISPLAY 5 CLEAR 6 COUNTER 7 START / LED 8 OPEN 9 FUNCTION / LED 10 NOTCH / LED Stops all the actions of the machine. Except when “HOT”shows on the LED display. Temporarily lowers the temperature of glue tan...
Page 8 - STARTUP; LOAD; Figure 4
8 1. Turn ON the power switch of PF-3200 as shown. The heater of PF-3200 willautomatically heat the glue to the presetworking temperature and display thestatus of the heating processes. • The 4 leftmost spaces of LED: the status of heating process (COLD,WARM, or HOT). • The 2 rightmost spaces of LED...
Page 9 - MANUAL MODE; Figure 5
9 After the “STARTUP” procedures, the PF-3200 will automatically set itselfMANUAL operation and flashing “LOADBOOK” display. Note that the “NOTCH”LED is ON. 1. A. Press the “OPEN” button and place the book block inside the clamps. Besure to follow the label instructionson the clamp to load the book ...
Page 10 - Figure 6; PUSH; OPEN
10 Note: If you accidentally remove ordrop the cover sheet during theclamping station returning to thenipping station, the control panel willshow “COVER?”. At this moment, youhave to place the cover on the nippingstation and press “START” button toresume the process. 5. When the display indicates “P...
Page 11 - AUTO MODE; Figure 7
11 Note: All books done in this mode mustbe same thickness. 1. In the MANUAL mode, make one book. Centering the cover to the centeredpoint and adjust the side guideaccordingly. 2. Press “FUNCTION” button to switch to “AUTO” operation. The “AUTO” LEDwill be lit and display flashing “LOADBOOK” as show...
Page 12 - Place the same thickness of book block; Figure 8; BIND; UNLOAD
12 Note: If you accidentally remove ordrop the cover sheet during theclamping station return to the nippingstation, the control panel will show“COVER?”. At this moment, you haveto place the cover on the nippingstation and press “START” button torecover the process. Having completed one bound book, t...
Page 13 - PADDING MODE; Figure 9
13 “PAD” is one of the PF-3200 operationsthat apply to special binding applicationssuch as binding without a cover sheet. 1. Press “FUNCTION” button to switch to “PAD” operation. The “PAD” LED will belit and display flashing “LOAD PAD” asshown. Note: The “NOTCH” LED is normallyOFF. But you can press...
Page 14 - STANDBY MODE; BOOK
14 STANDBY MODE Press “STANDBY” button, the PF-3200 willtemporarily lower the temperature of gluetank so it won’t burn the glue when themachine is not operated. The LED displays“STBY00” as shown below. Where “00” isthe timer display for the duration of thestandby period. Press “STANDBY” button again...
Page 15 - REPLENISHING THE GLUE TANK
15 The glue level may require adjustmentwhen the thickness of the book or padvaries. Use the following book spineillustrations for guidelines. • Increasing the holt-melt glue when • Decreasing hot-melt glue when • Adjusting the glue level: 1. Turn the glue adjustment lock knob counter clockwise to l...
Page 16 - MAINTENANCE; NP SVC
16 After you have finished using the binderfor the day, follow the following steps: 1. Close the clamps while the LED display flashing “LOAD BOOK” or “LOAD PAD”. 2. Press “START” and “CLEAR” keys simultaneously. The clamp station willautomatically move to the left of themachine and LED display “NP S...
Page 17 - SETUP FOR TIMERS; DEFAULT TIMES FOR TR
17 To enter the timer setup menu, you willneed to press and hold down both the“OPEN” and “CLOSE” buttons, then turnthe power on. You should see “SET TR” inthe LED DISPLAY. Press the“FUNCTION” button to sequentiallydisplay TR1, TR2, TR3, TR4, TR5, TR6,“SAVE”, “CANCEL”, and “RESET”. Onceyou have selec...