RX330 S1 Operating manual Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.1 Documentation overview . . . . . . . . . . . . . . . . . . . . 7 1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.3 Notational conventions . . . . . . . . . . ....
Page 7 - Introduction; Documentation overview; Concept and target groups for this manual
RX330 S1 Operating manual 7 1 Introduction The PRIMERGY RX330 S1 server is an AMD-based server for workgroups and small networks. The server is suitable for use as a file server and also as an application, information or Internet server. Thanks to its highly developed hardware and software component...
Page 9 - Features; System board; Hard disk drives
RX330 S1 Operating manual 9 Introduction Features Further sources of information: – Technical Manual for the relevant rack – Manual for the monitor – Manual on ServerView Server Management – Manual for the remote testing and diagnostic system RemoteView – Documentation for boards and drives – Docume...
Page 10 - Accessible drives; High level of availability and data security
10 Operating manual RX330 S1 Features Introduction Onboard SAS controller with Integrated Mirroring Enhanced functionality An onboard SAS controller with "Integrated Mirroring Enhanced" (IME) function-ality is fitted to operate the six hard drives. IME also offers RAID functionality for conf...
Page 14 - ServerStart; Service and support
14 Operating manual RX330 S1 Features Introduction ServerStart You can configure the PRIMERGY server quickly and precisely with the Server-Star t software provided. User-guided menus are available for installing the server operating system (for fur ther details see section “Configuring the server” o...
Page 16 - Notational conventions
16 Operating manual RX330 S1 Notational conventions Introduction 1.3 Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands, menu items or software programs. “Quotation marks” indicate names of chapters and terms that are being emphasi...
Page 17 - Technical data; Compliance with regulations and standards
RX330 S1 Operating manual 17 Introduction Technical data 1.4 Technical data Electrical data (hot-plug power supply unit) Compliance with regulations and standards Rated voltage range 100 V - 127 V or 200 V - 240 V Frequency 50 Hz - 60 Hz Rated current with basic configuration 100 V - 240 V / 1.7 A -...
Page 19 - Installation steps, overview
RX330 S1 Operating manual 19 2 Installation steps, overview This chapter contains an overview of the steps necessary to install your server. Links guide you to sections where you can find more detailed information on the individual steps: Ê First of all, it is essential that you familiarize yourself...
Page 21 - Important information; Safety
RX330 S1 Operating manual 21 3 Important information In this chapter you will find essential information regarding safety when working on your server. 3.1 Safety I The following safety instructions are also provided in the manual “Safety notes and other impor tant information”. This device complies ...
Page 22 - Before starting up; Installation and operation
22 Operating manual RX330 S1 Safety Important information Before starting up V CAUTION! ● During installation and before operating the device, observe the instructions on environmental conditions for your device (see section “Technical data” on page 17 ). ● If the server has been moved from a cold e...
Page 25 - Laser information
RX330 S1 Operating manual 25 Important information Safety Working with CDs/DVDs and CD/DVD drives When working with devices with CD/DVD drives, these instructions must be followed. V CAUTION! ● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data lo...
Page 26 - Batteries
26 Operating manual RX330 S1 Safety Important information Batteries V CAUTION! ● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system boa...
Page 28 - Other important information:; CE conformity
28 Operating manual RX330 S1 CE conformity Important information Other important information: ● During cleaning, observe the instructions in section “Cleaning the server” on page 60 . ● Keep this operating manual and the other documentation (such as the technical manual, CD) close to the device. All...
Page 29 - Transporting the server
RX330 S1 Operating manual 29 Important information Transporting the server ● Reorient or relocate the receiving antenna. ● Increase the separation between equipment and the receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ● Consult...
Page 30 - Notes on installing in the rack
30 Operating manual RX330 S1 Notes on installing in the rack Important information 3.5 Notes on installing in the rack V CAUTION! ● For safety reasons, at least two people are required to install the rack model because of its weight and size. ● Never lift the server into the rack using the handles o...
Page 31 - Environmental protection; Environmentally-friendly product design and development
RX330 S1 Operating manual 31 Important information Environmental protection 3.6 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and d...
Page 32 - Labels on plastic casing parts
32 Operating manual RX330 S1 Environmental protection Important information Labels on plastic casing parts Please avoid sticking your own labels on plastic par ts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal Details regarding the return and recycl...
Page 33 - Hardware installation; Minimum acclimatization time
RX330 S1 Operating manual 33 4 Hardware installation V CAUTION! ● Follow the safety instructions in the chapter “Impor tant information” on page 21 . ● Do not expose the server to extreme environmental conditions (see “Ambient conditions” on page 18 ). Protect the server from dust, humidity and heat...
Page 34 - Unpacking the server
34 Operating manual RX330 S1 Unpacking the server Hardware installation 4.1 Unpacking the server V CAUTION! Follow the safety instructions in the “Impor tant information” on page 21 chapter. The server must always be lifted or carried by at least two people. Do not unpack the server until it is at i...
Page 35 - Installing/removing the server in/from the rack
RX330 S1 Operating manual 35 Hardware installation Installing/removing the server in/from the rack 4.2 Installing/removing the server in/from the rack V CAUTION! ● Follow the safety instructions in chapter “Important infor- mation” on page 21 and section “Notes on installing in the rack” on page 30 ...
Page 39 - Installation in PRIMECENTER/DataCenter Rack
RX330 S1 Operating manual 39 Hardware installation Installing/removing the server in/from the rack 4.2.1 Installation in PRIMECENTER/DataCenter Rack For installation in a PRIMECENTER/DataCenter Rack, the following parts are required: – Support bracket – One left and one right telescopic rail (assemb...
Page 42 - Installation in 3rd party racks; Racks with installation depth of 735 mm
42 Operating manual RX330 S1 Installing/removing the server in/from the rack Hardware installation 4.2.2 Installation in 3rd party racks The following parts are required to install the server in 3rd par ty racks: – One left and one right telescopic rail (assembled) – M5x10 screws with integrated plu...
Page 43 - Inserting the server
RX330 S1 Operating manual 43 Hardware installation Installing/removing the server in/from the rack Racks with installation depth smaller/greater than 735 mm The lengths of the telescopic rails have to be adjusted with respect to each other when installing in rack systems with an installation depth g...
Page 44 - At least two people are needed to position the server in the rack.
44 Operating manual RX330 S1 Installing/removing the server in/from the rack Hardware installation Figure 7: Inserting the server V CAUTION! At least two people are needed to position the server in the rack. Ê Fully extend the fitted telescopic rails (1). They must click into place so that they can ...
Page 45 - Connecting devices to the server
RX330 S1 Operating manual 45 Hardware installation Connecting devices to the server 4.3 Connecting devices to the server The ports for external devices are on the rear of the server. The additional por ts available on your server depend on the options and PCI boards installed. The standard ports ( f...
Page 46 - Connecting the keyboard, mouse and monitor
46 Operating manual RX330 S1 Connecting devices to the server Hardware installation Figure 9: USB port on the front Connecting the keyboard, mouse and monitor Ê Connect the monitor, keyboard and mouse to the standard ports of the server (see table and figure 8 on page 45 ). I If a separate graphics ...
Page 47 - Connecting the server to the mains
RX330 S1 Operating manual 47 Hardware installation Connecting the server to the mains 4.4 Connecting the server to the mains In its basic configuration level the server has a hot-plug power supply unit. A second hot plug power supply unit can be added to achieve redundant power supply. If a defect o...
Page 48 - Notes on connecting/disconnecting cables; Connecting cables
48 Operating manual RX330 S1 Notes on connecting/disconnecting cables Hardware installation 4.5 Notes on connecting/disconnecting cables V CAUTION! Always read the documentation supplied with the device you wish to connect. Never connect, or disconnect cables during a thunderstorm. Never pull on a c...
Page 49 - Starting up and operation; Controls and displays; Front of server
RX330 S1 Operating manual 49 5 Starting up and operation V CAUTION! Follow the safety instructions in the chapter “Impor tant information” on page 21 . 5.1 Controls and displays 5.1.1 Front of server Figure 11: Controls and indicators on the front 1 HDD BUSY indicator 7 On/Off button 2 HDD FAULT ind...
Page 52 - HDD BU
52 Operating manual RX330 S1 Controls and displays Starting up and operation Indicators on the HDD module Figure 12: Indicators on the HDD module LED green HDD BUSY – lights: HDD in active phase – does not light: HDD inactive (drive inactive) LED red HDD FAULT (in conjunction with a RAID controller)...
Page 53 - Rear of server
RX330 S1 Operating manual 53 Starting up and operation Controls and displays 5.1.2 Rear of server Indicators on connection panel (global error indicator and ID indicator) Figure 13: Global error indicator and ID indicator 1 ID indicator (blue) Lights blue when the system has been selected by pressin...
Page 54 - Indicators on the connection panel (LAN indicators)
54 Operating manual RX330 S1 Controls and displays Starting up and operation Indicators on the connection panel (LAN indicators) Figure 14: LAN indicators 1 LAN link/active indicator (service LAN) Lights up green if a LAN connection exists.Does not light up if no LAN connection exists.Flashes green ...
Page 56 - Switching the server on and off; Switching the server on; System already installed:
56 Operating manual RX330 S1 Switching the server on and off Starting up and operation 5.2 Switching the server on and off V CAUTION! If nothing appears on the screen but flickering stripes after switching on the server, switch the server off immediately (see section “Flickering stripes on monitor s...
Page 58 - IPMI; Configuring the server; Configuring onboard SAS controller
58 Operating manual RX330 S1 Configuring the server Starting up and operation – IPMI The server is switched on by an IPMI console via serial port COM1 (item 8 in figure 8 on page 45 ) or via LAN por t M (item 3 in figure 8 on page 45 ). 5.3 Configuring the server This section contains information ab...
Page 59 - Configuration with ServerStart; The ServerStart advantages
RX330 S1 Operating manual 59 Starting up and operation Configuring the server 5.3.2 Configuration with ServerStart With the ServerStart Disc 1 provided, you can configure the server and install the operating system in a convenient manner. Menu-guided configuration includes server configuration with ...
Page 60 - Configuration without ServerStart; Operating system installation; Cleaning the server
60 Operating manual RX330 S1 Cleaning the server Starting up and operation 5.3.3 Configuration without ServerStart Configuring onboard SAS controller Configure the controller as described in section “Configuring onboard SAS controller” on page 58 . Operating system installation Ê Insert the CD for t...
Page 61 - Property and data protection; BIOS Setup security functions; Preventing unauthorized BIOS Setup calls; Preventing unauthorized system access
RX330 S1 Operating manual 61 6 Property and data protection The lockable rack door protects the server against unauthorized access. To protect your system and data internally against unauthorized access, you can use the BIOS Setup security functions. 6.1 BIOS Setup security functions The Security me...
Page 63 - Troubleshooting and tips; “Important information”; Power-on indicator remains unlit; Power cable incorrectly connected
RX330 S1 Operating manual 63 7 Troubleshooting and tips V CAUTION! Follow the safety instructions in the “Safety notes and other important information” manual and in the “Important information” on page 21 chapter. If a fault occurs, attempt to resolve it using the measures described: – in this chapt...
Page 64 - Server switches itself off; Screen remains blank
64 Operating manual RX330 S1 Server switches itself off Troubleshooting and tips 7.2 Server switches itself off Server Management has detected an error Ê Check the error list or the ErrorLog file in the ServerView program, and attempt to eliminate the error. 7.3 Screen remains blank Monitor is switc...
Page 65 - Flickering stripes on monitor screen; Monitor does not support the set horizontal frequency; No screen display or display drifts; Mouse driver not loaded
RX330 S1 Operating manual 65 Troubleshooting and tips Flickering stripes on monitor screen 7.4 Flickering stripes on monitor screen V CAUTION! Switch off the server immediately. Risk of damaging the server. Monitor does not support the set horizontal frequency Ê Find out which horizontal frequency y...
Page 66 - Incorrect date and time; SAS configuration incorrect
66 Operating manual RX330 S1 Incorrect date and time Troubleshooting and tips Mouse controller disabled The mouse controller on the system board must be enabled if you are using the mouse supplied. Ê Check in the BIOS Setup that the mouse controller is Enabled . 7.7 Incorrect date and time Ê Set the...
Page 67 - RAID controller configuration incorrect; Added drive reported as defective; RAID controller is not configured for this drive; Error message on screen
RX330 S1 Operating manual 67 Troubleshooting and tips Drives reported as “dead” when starting system 7.9 Drives reported as “dead” when starting system This error message can occur when the onboard SAS controller has RAID functionality or the server is equipped with a PCI RAID controller. RAID contr...
Page 69 - Hot-plug power supply units
RX330 S1 Operating manual 69 8 Hot-plug components This chapter describes how to handle the hot-plug components and how to modify your server hardware (e.g. installing/removing hot-plug power supply units or hot-plug HDD modules) . I Upgrades, updates and replacement of non-hot-pluggable components ...
Page 70 - Remove the dummy module
70 Operating manual RX330 S1 Hot-plug power supply units Hot-plug components 8.1.1 Remove the dummy module The mounting location for the second hot-plug power supply unit contains a dummy module. This dummy module must be removed before installing a second power supply unit. Figure 16: Remove the du...
Page 71 - Installing/removing the hot-plug power supply unit
RX330 S1 Operating manual 71 Hot-plug components Hot-plug power supply units 8.1.2 Installing/removing the hot-plug power supply unit Figure 17: Unlocking and installing the power supply unit Ê Fold down the locking lever (1) and slide the power supply unit into the mounting location (2) as far as i...
Page 72 - Replacing the hot-plug power supply unit
72 Operating manual RX330 S1 Hot-plug power supply units Hot-plug components 8.1.3 Replacing the hot-plug power supply unit V CAUTION! Before replacing a non-defective power supply unit in a non-redundant configuration (only one power supply unit present), the server must have been switched off. Ê R...
Page 73 - Hot plug hard disk drives
RX330 S1 Operating manual 73 Hot-plug components Hot plug hard disk drives 8.2 Hot plug hard disk drives Up to six hot-plug hard disk drives can be installed in the PRIMERGY RX330 S1 Server. The hard disk drives which can be ordered for the PRIMERGY RX330 S1 are supplied already mounted in an instal...
Page 75 - Handling hard disk drives and HDD modules
RX330 S1 Operating manual 75 Hot-plug components Hot plug hard disk drives 8.2.1 Handling hard disk drives and HDD modules Hard disk drives incorporated in the HDD modules are highly sensitive electro-magnetic devices and must be handled with great care. Incorrect handling can cause partial or total...
Page 76 - Removing/Installing the dummy module
76 Operating manual RX330 S1 Hot plug hard disk drives Hot-plug components 8.2.2 Removing/Installing the dummy module Free slots are provided with dummy modules. Remove the dummy module before installing an additional HDD module. Figure 18: Removing the dummy module Ê Press both tabs on the dummy mo...
Page 77 - Installing/removing the HDD module; Unlocking the HDD module
RX330 S1 Operating manual 77 Hot-plug components Hot plug hard disk drives 8.2.3 Installing/removing the HDD module Unlocking the HDD module I If HDD modules are provided with a transpor t lock, remove the lock before releasing the locking mechanism. Figure 19: Removing the transport lock Ê Pull the...
Page 81 - Abbreviations
RX330 S1 Operating manual 81 Abbreviations AC Alternating Current ANSI American National Standard Institut ASR&R Automatic Server Reconfiguration and Restar t ATA Advanced Technology Attachments BIOS Basic Input-Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk...
Page 87 - Literature; Safety notes and other important information
RX330 S1 Operating manual 87 Literature PRIMERGY server manuals are also available as PDF files on the ServerBooks DVD. The ServerBooks DVD is part of the PRIMERGY ServerView Suite , which is supplied with every server. The current versions of the required manuals may be downloaded for free from the...
Page 89 - Index
RX330 S1 Operating manual 89 Index 3rd par ty rack installing in 42 requirements 37 AAccessible drives CD-RW 10 DVD-RW 10 magnetic tape drive 10 Acclimatization time 33 , 75 Advanced Video Redirection 11 Ambient conditions 18 Articulated cable guide 41 ASR&R 11 Availability 10 AVR 11 BBIOS updat...