Page 3 - Continued
Preface Procedure Safety Instructions Preparation Main Memory Processors Accessible Drives Controllers in Non-Hot-Plug PCI Slots RemoteView Components Completion Continued
Page 7 - Contents
Options Guide Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Overview of the documentation . . . . . . . . . . . . . . . . . . 1 1.2 Extensions and conversions . . . . . . . . . . . . . . . . . . . . 3 1.3 Notational conventions . . . . . . . . . . . . . . . . ....
Page 9 - Preface; Overview of the documentation; Concept and target groups
Options Guide 1 1 Preface The PRIMERGY RX200 S2 is an Intel-based server for mid-tier applications in server farms. The server is well suited for front end services as well as for use as an e-mail server, Internet server, or general applications server. 1.1 Overview of the documentation I PRIMERGY m...
Page 11 - Extensions and conversions; Second processor
Options Guide 3 Preface Extensions and conversions 1.2 Extensions and conversions Second processor The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency as the first processo...
Page 12 - Additional controllers in non-hot-plug PCI slots
4 Options Guide Extensions and conversions Preface Additional controllers in non-hot-plug PCI slots The system board offers two PCI-X slots: – PCI-X slot 1: 64 bit/133 MHz, max. length 315 mm – PCI-X slot 2: 64 bit/66 MHz, low profile, max. length 175 mm I Both slots are not hot-pluggable. RemoteVie...
Page 13 - Notational conventions
Options Guide 5 Preface Notational conventions 1.3 Notational conventions The following notational conventions are used in this manual: Italics indicate commands, menu items or software programs. “Quotation marks” indicate names of chapters and terms that should be emphasized. Ê text which follows t...
Page 15 - Procedure
Options Guide 7 2 Procedure V CAUTION! ● The actions described in this manual should only be performed by engineers, service personnel or technical specialists. ● Equipment repairs should only be performed by authorized, qualified staff. ● Any failure to observe the guidelines in this manual, and an...
Page 17 - Safety Instructions; Before setting up
Options Guide 9 3 Safety Instructions I The following safety instructions can also be found in the manual entitled “Safety”. This device complies with the relevant safety regulations for data processing equipment, including electronic office machines for use in an office environment. If you have any...
Page 18 - Installation and operation
10 Options Guide Safety Instructions Installation and operation V CAUTION! ● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for t...
Page 20 - Batteries
12 Options Guide Safety Instructions Batteries V CAUTION! ● Incorrect replacement of batteries may lead to risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board under “Related publi...
Page 21 - Note on the laser
Options Guide 13 Safety Instructions I To protect the CD-ROM/DVD drive and prevent mechanical damage, as well as premature wearing of the CDs, you should observe the following advice: – Only inser t the CDs in the drive when needed and remove them after use. – Store the CDs in suitable sleeves. – Pr...
Page 23 - Preparation; Opening the server
Options Guide 15 4 Preparation V CAUTION! Please observe the safety information in the chapter “Safety Instructions” on page 9ff. 4.1 Opening the server Ê Exit all applications and shut down the server correctly. Ê Press the on/off button. Ê Unplug the power plugs. Figure 2: Removing the server Ê Un...
Page 25 - Main Memory; Installation rules
Options Guide 17 5 Main Memory V CAUTION! Please observe the safety information in the chapter “Safety Instructions” on page 9ff. The eight slots for the main memory are suitable for PC2-3200 DDR-II DIMM memory modules. The board suppor ts a maximum of 13-16 Gbytes of main memory (depending on the c...
Page 26 - Upgrading / exchanging main memory
18 Options Guide Upgrading / exchanging main memory Main Memory 5.2 Upgrading / exchanging main memory Ê Open the server as described in the chapter “Preparation” on page 15f. Figure 4: Removing a memory module Ê Flip the ejector tabs on each side of the slot outward (1). This levers an installed me...
Page 27 - Processors; Installing a second processor
Options Guide 19 6 Processors V CAUTION! Please observe the safety information in the chapter “Safety Instructions” on page 9ff. V CAUTION! Processors are components which are extremely sensitive to electro-static discharge and must be handled with caution. When you take a processor out of its prote...
Page 28 - Removing the ventilation duct
20 Options Guide Installing a second processor Processors Removing the ventilation duct Figure 6: Removal of the ventilation duct Ê Lift off the ventilation duct upwards.
Page 29 - Installing the processor
Options Guide 21 Processors Installing a second processor Removing the heat sink dummy Figure 7: Removing the heat sink dummy Ê Remove the heat sink dummy. Installing the processor Figure 8: Opening the socket lever Ê Release the socket lever by pressing it sideways and lifting it up as far as it wi...
Page 31 - Installing the ventilation duct
Options Guide 23 Processors Installing a second processor Installing the heat sink Figure 10: Installing the heat sink Ê Fit the heat sink on the processor such that the side labeled “FRONT” (see arrow (1) in figure above) is facing the front of the server. Ê Attach the heat sink with four screws. T...
Page 32 - Exchanging the processor
24 Options Guide Exchanging the processor Processors 6.2 Exchanging the processor V CAUTION! You may only use processors of the same type on the system board. Ê Open the server as described in the chapter “Preparation” on page 15f. Ê Remove the ventilation duct (see page 20). Figure 11: Removing the...
Page 35 - Exchanging the heat sink
Options Guide 27 Processors Exchanging the heat sink 6.3 Exchanging the heat sink Ê Open the server as described in the chapter “Preparation” on page 15f. Ê Remove the ventilation duct (see page 20). Ê Remove the four screws of the heat sink in diagonally opposite sequence (see page 24). Ê Turn the ...
Page 37 - Accessible Drives
Options Guide 29 7 Accessible Drives V CAUTION! Please observe the safety information in the chapter “Safety Instructions” on page 9ff. The PRIMERGY RX200 S2 server offers a total of two slots for accessible drives. Available are a floppy disk drive and a CD-ROM/DVD drive. Instead of the floppy driv...
Page 38 - Installing the LocalView Module
30 Options Guide Installing the LocalView Module Accessible Drives 7.1 Installing the LocalView Module The LocalView module is an optional extra for servers in the PRIMERGY series. It allows you to read status messages directly from the server on the LocalView display panel. These status messages pr...
Page 40 - Removing the dummy cover
32 Options Guide Installing a CD-ROM/DVD drive Accessible Drives 7.2 Installing a CD-ROM/DVD drive You can install a CD-ROM/DVD drive in the top right bay (seen from the front). If the bay is empty, a dummy cover will have been fitted. Removing the dummy cover Figure 16: Dummy cover Ê Remove the dum...
Page 43 - Installing a floppy disk drive
Options Guide 35 Accessible Drives Installing a floppy disk drive 7.3 Installing a floppy disk drive You can install a floppy disk drive in the top left bay (seen from the front). If the bay is empty, a dummy cover will have been fitted. Removing the dummy cover Figure 19: Dummy cover Ê Remove the d...
Page 44 - Removing/installing a floppy disk drive
36 Options Guide Installing a floppy disk drive Accessible Drives Removing/installing a floppy disk drive Figure 20: Mounting the drive in its frame Ê Inser t the floppy disk drive in its frame and secure it with two screws. Ê Push the floppy disk drive in its frame into the bay from the front until...
Page 48 - Installing controllers; Removing the riser card holder; Installing a PCI board
40 Options Guide Installing controllers Controllers in Non-Hot-Plug PCI Slots 8.1 Installing controllers Ê Open the server as described in the chapter “Preparation” on page 15f. Removing the riser card holder Figure 22: Removing the riser card holder Ê Undo the two knurled screws (see figure). Ê Pul...
Page 49 - Reinstalling the riser card holder
Options Guide 41 Controllers in Non-Hot-Plug PCI Slots Installing controllers Figure 23: Mounting the board Ê Plug the board into the PCI slot on the riser card that is suitable for the height of the board. I Make sure that the slot cover fits into the appropriate recess. Ê If necessary, plug in the...
Page 51 - RemoteView Components
Options Guide 43 9 RemoteView Components V CAUTION! Please observe the safety information in the chapter “Safety Instructions” on page 9ff. 9.1 Installing the RemoteView Service Board S2 LP I How to install/remove and configure the RSB S2 LP is described in detail in the manual “RemoteView Service B...
Page 53 - Completion; Closing the server
Options Guide 45 10 Completion V CAUTION! Please observe the safety information in the chapter “Safety Instructions” on page 9ff. 10.1 Closing the server Figure 25: Installing the cover Ê Position the cover in such a way that the rear edge protrudes 3-4 cm from the housing. Ê Push the cover to the f...
Page 55 - Abbreviations
Options Guide 47 Abbreviations AC Alternating Current ANSI American National Standards Institute ASR&R Automatic Server Reconfiguration and Restar t BIOS Basic Input/Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk CD-ROM Compact Disk Read-Only Memory CHS Cyli...
Page 61 - Related publications; Safety
Options Guide 53 Related publications PRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is par t of the ServerStart Bundle delivered with each server system. The actual version of the necessary manuals can be downloaded free of charge from the Internet. The overvie...
Page 63 - Index
Options Guide 55 Index Aaccessible drives 3additional documentation 1 Bbatteries 12 CCD-ROM/DVD drive installation 33upgrade 32 controller 4 upgrade 40 cover installation 45removal 16 Ddual-processor mode 19dummy cover 32, 35 EEGB label 13electrostatic sensitive devices 13ESD 13ESD label 13exchange ...
Page 65 - Comments
Comments on PRIMERGY RX200 S2 Serversystem Comments Suggestions Corrections ✁ Submitted by Fujitsu Siemens Computers GmbHUser Documentation33094 PaderbornGermany Fax: 0 700 / 372 00001 email: [email protected]://manuals.fujitsu-siemens.com