Fluke T6-1000 - User Manual

Fluke T6-1000

Fluke T6-1000 Voltage Tester – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

HO

LD

3

2

1

5

7

6

200

A

CA

T

10

00

V

CA

T

60

0

V

4

HOLD

200

A

CA

T

10

00

V

CA

T

60

0

V

AUTO

SELECT

T6-1000

ELECTRICAL TESTER

5

2

7

3

1

4

6

True

RMS

Test Lead Assembly (T5-RLS) Replace

only with Fluke double-insulated leads (

) PN 4462973

TP1 Single Probe, Flat-Tip, Red

PN 648128

TP1 Single Probe, Flat-Tip, Black

PN 648102

TP38 Single Probe, Round-Tip, Red

PN 1276841

TP38 Single Probe, Round-Tip, Black

PN 1276852

Battery Door

PN 4944370

Battery Door Screw

PN 1618578

Use only specified replacement parts

Quick Reference Guide

Model T6-1000 Model T6-600

Function

Requires

Test Leads

Range

Range

Resolution

Accuracy

[1]

FieldSense

Voltage ac true-rms

No

1000 V

600 V

1 V

±(3 % + 3 counts)

45 Hz to 66 Hz

[2] [3]

FieldSense

Current ac true-rms

No

200.0 A

200.0 A

0.1 A

±(3 % + 3 counts)

45 Hz to 66 Hz

FieldSense

frequency (Hz)

No

45 Hz to 66 Hz

1 Hz

±(1 % + 2 counts)

[3]

Voltage ac true-rms

Yes

1000 V

600 V

1 V

±(1.5 % + 2 counts)

45 Hz to 66 Hz

Voltage dc

Yes

1000 V

600 V

1 V

±(1 % + 2 counts)

Resistance

Yes

2000 Ω

2000 Ω

1 Ω

±(1 % + 2 counts)

Yes

20.00 kΩ

0.01 kΩ

Yes

100.0 kΩ

0.1 kΩ

[1] Accuracy: ±( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at

18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are accoupled, RMS responding.

[2] Add 3 % typical without an external ground connection. External ground connection required for user wearing insulated

gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

[3] FieldSense is specified from 16 V to 100 % of range.

Fork opening

17.8 mm

Temperature
Operating
Storage

-10 °C to +50 °C (+14 °F to +122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)

Altitude
Operating
Storage

2000 m
10 000 m

Relative Humidity

0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)

Battery Type and Life

2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function

Temperature coefficient

0.1 x (specified accuracy) / °C for <18°C or >28 °C (<64.4 °F or >82.4 °F)

T6-600/T6-1000

Electrical Tester

with FieldSense Technology

»

See

Safety Information.

Go to www.fluke.com to register your product and find more information, or

download this Quick Reference Guide in other languages.

PN 4897598 September 2017 Rev. 4, 7/18

© 2017-2018 Fluke Corporation. All rights reserved.

Specifications are subject to change without notification.

Fork Opening 17.8 mm

Overview

Wire Position

1 Wire Only

Finger Guard

For safe operation, hold the

Tester behind the finger guard.

Display

Model T6-1000

Model T6-600

X

Hazardous Voltage ≥30 V

Function Selection/On/Off

Auto Off

15 min

FieldSense Ground Contact

Test Probes/Storage Dock

Symbols

W

WARNING. RISK OF DANGER.

Test with fork and FieldSense ground contact.

»

Consult user documentation.

Test with fork and ground probe.

Y

Hazardous voltage ≥30 V.

Test with probes.

Battery full charge.

FieldSense Measurement: Fluke voltage/current

sensing technique.

Battery low. Replace.

J

Good earth ground connection.

Back light

J

No earth ground connection.

Specifications

USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566-5655
China: +86-400-921-08365
Anywhere in the world: +1-425-446-5500

● HT6 Belt Holster
● TPAK Hanger
● PRV240FS Proving Unit
● AC285 SureGrip™ Alligator Clips
● AC220 SureGrip™ Alligator Clips
● C60 softcase

Contact Fluke

USA:

.

Lead Replacement

Accessories

● HT6 ●

Replacement Parts

Wire must contact

the bottom of the

fork opening.