Fedders Split System Air Conditioner - Manual
Fedders Split System Air Conditioner – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INTRODUCTION; NOTES TO INSTALLER; DANGER; INSPECTION AND UNPACKING
- Page 3 – Electrical Connections
- Page 4 – SERVICE VALVE CONNECTIONS; Braze joints; Model; Opening the Service Valve (Straight Valve)
- Page 5 – CONNECT REFRIGERANT PIPING; Precautions
- Page 6 – SUB-COOLING CHARGING; FINAL CHECKS FOR INSTALLER
- Page 7 – VF; CONDENSING UNIT
- Page 8 – LIMITED WARRANTY
Installation, Operation and Maintenance
1.5 Through 5 Ton
Split System Air Conditioner
INTRODUCTION ..............................................................................1
NOTES TO INSTALLER ....................................................................1
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS ................1
CODES ............................................................................................1
INSPECTION AND UNPACKING ......................................................1
INSTALLATION
Clearances ..........................................................................2
Support ..............................................................................2
Exposure ............................................................................2
Proximity to Evaporator....................................................2
ELECTRICAL CONNECTIONS ..........................................................2
SERVICE VALVE CONNECTIONS
Braze Joints ..............................................................................3
Evacuation ................................................................................3
Opening the Service Valve (Step Valve) ................................3
CONNECT REFRIGERANT PIPING ..................................................4
Precautions ................................................................................4
Liquid Line Sizes ........................................................................4
Suction Line Sizes ......................................................................4
SUBCOOLING CHARGING ............................................................5
OPERATION INSTRUCTIONS ..........................................................5
MAINTENANCE INSTRUCTIONS ....................................................5
CONDENSING UNIT NOMENCLATURE ..........................................6
LIMITED WARRANTY ....................................................................7
NOTE:
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT
AND OPERATION OF THIS EQUIPMENT. READ THE ENTIRE
INSTRUCTION MANUAL THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION.
TABLE OF CONTENTS
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
INTRODUCTION You have made a major investment in a fine piece ofequipment. Keep your investment sound by reading theseinstructions before installing this unit. This will ensure thatthe full potential of this equipment is achieved. It will alsobe helpful in avoiding any needless service costs oropera...
2 Six feet clearance above the unit Three feet clearance Rain Gutters Concrete slabor preformed pad Three feet clearance INSTALLATIONCondensing Unit Location The condensing unit should be located outdoors as close aspossible to the evaporator. Consider the following factors: Clearances The air inlet...
SERVICE VALVE CONNECTIONS Braze joints 1. Remove the valve core from the schrader port. Wrap aquenching cloth around the service valve. Clean and fluxthe joint and braze with brazing rod containing at least10% silver (such as silphos type brazing rod). DO NOT USESOFT SOLDER. Replace the schrader val...