Fedders FV80 Series - Manual
Fedders FV80 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Product Specifications; PRODUCT SPECIFICATIONS
- Page 3 – CLEARANCE TO COMBUSTIBLES; FIELD-INSTALLED ACCESSORIES
- Page 4 – Variable Speed
FV80 Series 2-Stage Variable Speed Gas Furnace
FV80 Series
All-Position Gas Furnace
80% AFUE – Two-Stage, Variable Speed
The Fedders 80% AFUE 2-Stage Variable Speed All-Position gas
furnaces are among the smallest in the industry and are suitable
for a variety of installations. The FV80 Series furnace provides
homeowners with consistent air circulation and temperature
control, resulting in lower monthly energy bills.
APPLICATIONS:
Perfect for a variety of installations. Free standing in an attic,
utility room, closet, alcove or basement.
EFFICIENCY:
80% AFUE
Variable speed blower motor, two-stage heating and two-stage
inducer allows for quiet operation and less energy consumption
EASY TO INSTALL AND SERVICE:
Built-in self diagnostics
Humidifier and electronic air cleaner terminals
Factory shipped for natural gas, with LP
Gas Conversion kits available
All position capability
Left or right side gas and electric entry
Single or two-stage thermostat ready
MODEL
INPUT
(BTUH)
EFFICIENCY
AFUE
COOLING
CAPACITY
UNIT DIMENSIONS
H x W x D (Inches)
WEIGHT (lbs.)
SHIPPING
OPERATING
FV80A070-4A
68,000
80%
1.5 - 3.5
35 x 17 1/2 x 28 1/4
132
119
FV80A085-4A
85,000
80%
2 - 4
35 x 20 1/2 x 28 1/4
146
132
FV80A115-5A
115,000
80%
2.5- 5
35 x 22 x 28 1/4
163
147
EFFICIENCY
RATING
CERTIFIED
ama
Specifications subject to change without notice.
STANDARD FEATURES:
Designed for all-position installation: upflow, downflow
and horizontal
35" high for ease of installation
Heavy-duty aluminized tubular heat exchanger is tested
to double the standard requirements for life cycle testing
with no signs of wear or corrosion
Industry proven, integrated hot surface ignition control
with igniter and flame sensor positioned in coolest part
of flame for ultimate performance and longevity
Aluminized-steel, multi-port inshot burners provide
smooth ignition coupled with superior flame stability,
low noise and reliability
Two speed draft inducer
California low NO
X
approved
Multi-port in-shot burners
Insulated cabinet to increase efficiency and
reduce sound levels
Two-stage gas valve
WARRANTY:
20-year limited warranty on heat exchanger
5-year limited warranty on all other parts
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Product Specifications 2 Specifications subject to change without notice. NOTES: 1. Values based on Natural Gas usage 2. Important: It is required to size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes PRODUCT ...
Product Specifications 3 Specifications subject to change without notice. DIMENSIONS (inches) MODEL WIDTH A DEPTH B HEIGHT C SUPPLY F x G FV80A070 - 4A 17 1/2 28 1/4 35 16 1/2 X 19 FV80A085-4A 20 1/2 28 1/4 35 19 1/2 X 19 FV80A115-5A 22 28 1/4 35 21 X 19 MODEL RETURN VENT SIDE D x E BOTTOM J x K L H...
Fedders Corporation505 Martinsville Rd.Liberty Corner, NJ 07938 USA(908) 604-8686Form No. F-V80 - 0607 All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2...