Fedders FV95A072 - Manual

Fedders FV95A072

Fedders FV95A072 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
Page: / 50

Table of Contents:

  • Page 2 – Table of Contents
  • Page 8 – CLEARANCES; Table 2 provides the certified clearances to combustibles.; DANGER; TABLE 2: CLEARANCES TO COMBUSTIBLES; IMPORTANT
  • Page 9 – DUCTWORK; CAUTION
  • Page 10 – General Considerations
  • Page 11 – Instructions for Re-orienting Air Inducer; FIGURE A : RIGHT INDUCER POSITION; SUSPENDED INSTALLATION; Horizontal Suspended Installation
  • Page 12 – Upflow Installation; If exhaust vent; COMBUSTION AIR
  • Page 13 – Downflow Installation; WARNING
  • Page 15 – FURNACE LOCATED IN A CONFINED SPACE, OUTDOOR; FURNACE LOCATED IN A CONFINED SPACE; NOTE; FURNACE LOCATED IN AN UNCONFINED SPACE
  • Page 16 – Direct Venting Pipe Connections; FURNACE VENTING; Combustion Air Inlet Piping
  • Page 17 – Definitions; Air Filters; Exhaust Vent Piping
  • Page 18 – Guidelines; Venting may be vertical or horizontal.; JOINING PIPE AND FITTINGS; PVC PRIMER AND SOLVENT CEMENT: ASTM D2564; condensate drains towards the furnace.
  • Page 19 – After checking the pipe and socket for proper fit, wipe; Apply a thin coat of solvent cement to the inside sur-; Direct Vent Piping Termination; General Guidelines; Caulk all cracks, seams or joints within a 6 foot radius of
  • Page 20 – MODEL; Count concentric vent fitting as straight pipe.; Calculating Piping Length
  • Page 22 – Horizontal Combustion Air Termination
  • Page 23 – Vertical Combustion Air Termination; AND EXHAUST VENT
  • Page 24 – Connecting a Non-Direct Vent to the Furnace; IN CANADA
  • Page 25 – family dwellings and serves both dwellings; Other Then Direct Vent Terminal Clearances
  • Page 26 – Direct Vent Terminal Clearances
  • Page 27 – CONDENSATE DRAINS; DRAIN HOSE INSTALLATION
  • Page 28 – HORIZONTAL FLOW RIGHT; HORIZONTAL FLOW LEFT
  • Page 30 – GAS SUPPLY; The gas piping may enter the furnace from either side.; Leak Testing; The L.P. gas inlet supply pressure should be 11 to 13 inches
  • Page 31 – Conversion Steps; Pin Connector; If converting the gas valve, the regulator spring is
  • Page 34 – Low Voltage Wiring; ELECTRICAL SPECIFICATIONS; Furnace Connection; USE COPPER CONDUCTORS ONLY
  • Page 35 – ISOLATION RELAY; THERMOSTAT LOCATION; START UP PROCEDURES; Sequence of Operation
  • Page 36 – Setting the Gas Pressure; Checking Furnace Input
  • Page 37 – AIRFLOW; Heating Value of Gas X 3000; Adjusting Dip Switches
  • Page 38 – DIP Switch Configurations; Cool
  • Page 39 – ADJUSTING BLOWER SPEEDS; How To Remove The Blower
  • Page 40 – TABLE 8; MAINTENANCE
  • Page 41 – Troubleshooting; Humidifiers/ Electronic Air Cleaners
  • Page 43 – TABLE 9
  • Page 46 – FIRE OR EXPLOSION HAZARD; TABLE OF CONTENTS; User’s Information Manual
  • Page 47 – FIGURE 2; GAS REGULATOR VENT; GENERAL SAFETY RULES
  • Page 48 – FURNACE OPERATION INFORMATION; Furnace Shut; Furnace Shutdown Procedure; FIGURE 3
  • Page 49 – FIGURE 4; AIR FILTER
Loading the manual

Installation, Operation and Maintenance

HIGH EFFICIENCY
TWO STAGE VARIABLE SPEED

Please read the operating instructions and safety
precautions carefully and thoroughly before installing
and operating your furnace. Keep this manual in a
safe place for future reference.

USER’S INSTRUCTION GUIDE

INSTALLATION, OPERATION AND
MAINTENANCE MANUAL

Model

Serial Number

Date of Purchase

For future reference write down the model, serial
number, and date of purchase. Use these numbers in
any correspondence or service calls concerning your
furnace.

Keep these instructions for future reference.

CATEGORY I NATURAL GAS AND LP GAS

WARM AIR FURNACE

LOCATED AFTER PAGE 43 OF THIS

23-23-0508N-003

MODEL 77FV

95

A054 FV

95

A072

<

FV

95

A0

90

<

FV

95

A108

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table of Contents

S S C Case 1: Furnace Located In An Case 2: Furnace Located In A Case 3: Furnace Located In A Confined Space, Case 4: Furnace Located In A Confined Space, Sequence of Operation if the Furnace Circulating Air Blower and FIELD SUPPLIED AND INSTALLED Table of Contents AIR CONDITIONING INSPECTION/ACCESS...

Page 8 - CLEARANCES; Table 2 provides the certified clearances to combustibles.; DANGER; TABLE 2: CLEARANCES TO COMBUSTIBLES; IMPORTANT

G A C G B F E D J L L K 1 DIMENSIONS (Inches) MODELINPUT WIDTH DEPTH HEIGHT SUPPLY AB C F x G RETURN SIDE BOTTOM D x E J x K L H 1 Vent outlet 4” - Use reducer fittings. 2 Two return air openings required 54,000 72,000 90,000 108,000 54,000 72,000 90,000 108,000 17.5 20.5 20.5 24.5 14 x 22 16 x 19 3...

Page 9 - DUCTWORK; CAUTION

DUCTWORK Proper airflow is required for the correct operation of thisfurnace. Insufficient airflow may cause erratic operation,could cause the furnace to cycle on the high temperaturelimit, and may damage the heat exchanger. Excessiveairflow may result in an excessively noisy duct system andmay resu...

Other Fedders Models

All Fedders Other