Handle tough applications in any environment...
because tests are required everywhere!

Inspection oriented and easy
to use

• 40 dB dynamic DAC/TCG

enables cor rection for
distance/amplitude var-
iations due to material loss
and beam spread Cur ve
displayed on A-Scan.
(USN 52L/R)

• RF display mode improves

signal evaluation and bond
inspection of dissimilar ma-
terials and assists crack tip
detection and sizing.
(USN 52L/R)

• Selectable rep rate

minimizes wraparound.

• Selectable damping control

provides transducer
matching for broader range
of applications.

• Angle beam trigonometric

functions display sound
path, projection, and depth
measurements to flaw.

• Magnification window

displays measurement
value in lar ge,easy to r ead
digits.

• Gate monitors amplitude

and soundpath distance for
both flaw and thickness
applications.

• Multi-echo or inter face-to-

first thickness measur e-
ment mode, with selectable
flank or peak detection.

• A-Scan freeze, freeze peak,

and zoom functions.

• Lock key prevents ac-

cidental change of settings.

Documentation and recording

• On-board thickness data

logger stores a total of
2,500 readings in up to 99
configurable files.

• RS-232 bidirectional

inter face for transfer ring
data, A-scan displays, and
repor ts to a printer, com-
puter, and for remote control.

• Stores instr ument control

datasets with A-Scans in
memor y for quick and
repeatable calibration.

• Amplitude and time of flight

analog output enables
recording via strip char t or
digitizing device.

(USN 52L/R)

• Direct printing of inspection

repor ts.

Lightweight, advanced and
reliable

• 6 pounds (2.7 kg) total

weight with batteries.

• Sealed case and membrane

keypad are splashproof,
r ugged and easy to clean

• Operates on AC or 6 “D” size

alkaline or NiCad batteries in
a detachable housing

Por table Ultrasonic Flaw Detectors

High Resolution LCD and EL Displays

USNLBRPF8985K

Printed in USA

Krautkramer Branson

50 Industrial Park Road
Lewistown, PA 17044
Tel: 1-717-242-0327
Fax: 1-717-242-2606
E-Mail: [email protected]

Buehler Krautkramer Ltd

University of War wick
Science Park
GB-Coventr y CV4 7HS
Tel: +44-1203-690069
Fax: +44-1203-693032
E-Mail: buehlerkrautkramer

@compuser ve.com

Krautkramer France

ZAC Sans Souci
68, Chemin des Or meaux
69 760 Limonest France
Tel: +33-47-217-9220
Fax: +33-47-847-5698

Krautkrämer GmbH & Co.

Rober t-Bosch-Str.3
D-50354 Hür th (Ef feren)
Postfach 1363
D-50330 Hür th
Tel: +49-2233-601-0
Fax: +49-2233-601-402
E-Mail: [email protected]

www.krautkramer.com

Our facility’s quality
system conforms to
ISO 9001.
ANSI/ASQC Q91.

Krautkramer Italiana,
una divisione della
Krautkramer France SA

68, Chemin des Or meaux
69 760 Limonest France
Tel: +167-790-880
Fax: +167-780-881

USN Series

Flaw Detector
Specifications

Common to All Instruments:

Standard Package

Lightweight Ultrasonic Flaw Detector
Batter y Char ger/AC Power Supply
Six D-Size NiCad Batteries
Detachable Batter y Holder Char ging Frame
Operating Manual

Recommended Accessories

Combination soft protective car r y case with
light shield and shoulder neck strap.
UltraDOC Documentation Software
9 Pin Serial PC Cable
Serial/Parallel Printer Cable
External Char ger Adapter Cable
Additional Batter y Char ging Frame
Additional NiCad Batteries (6)
Attachable Audible Alar m
Batter y Belt Pack
Analog Output Cable
Hard Shell Transpor t Shipping Container
Transducer Kits

Range

0.2" to 200" at steel velocity (5mm to
5000mm), range selectable in fixed steps, or
continuously variable

Velocity

Continuously adjustable from .0394 to .3936
in/µsec (1000-9999 m/second);
2 programmable fixed velocities

Delay

Minus 20 µsec to 999 µsec

Zero Of fset

0 to 1600 µsec

Gain

0 to 110 dB controllable in selectable gain
steps 0.1, 0.5, 1.0, 2.0, 6.0, and 24.0
(24dB step is programmable to other values)

Test Modes

Pulse echo and dual

Pulser

Spike/excitation pulse

Pulse Repetition Fr equency

Selectable, low & high; varies w/range

Rectification

Positive halfwave,negative halfwave,fullwave

Reject (suppression)

Controllable 0 to 80% absolutely linear

Units

Inch or millimeter selectable

Display

“R” Version: 5.75" x 2.65" (146mm x 67mm)
high resolution EL with selectable brightness;
hollow and solid A-Scan
60 Hz update rate
Pixel density 552 x 256
“L” Version: 4.5" x 3.0" (114mm x 76mm)
Transr eflective LCD with backlight
60 Hz update rate
Both displays have Scr een Savers
Pixel density 480 x 320

Gate Monitor

Controllable over entire sweep range in 0.1mm
increments. Alar m indication by LED.
Threshold contr olled 10% to 90% screen
height. Separate second threshold and star t
control in multi-echo measurement mode.

Measur ement Modes

Zero to first echo, 0.001" (0.1mm) resolution
up to 10" (245mm) ; multi-echo in gate with
controllable second threshold; time-of-flight to
peak or flank in gate; amplitude evaluation as
% FSH or above threshold to 127%; dB
reference indicates REF gain and addition or
subtraction; trigonometric flaw location

Memor y

Dataset memor y locations stor e all
instr ument parameters plus A-Scan. Recall
function displays stored dataset.

Data Logger

2,500 r eading sequential thickness measure-
ment storage with clear, review and dir ect
repor t featur e; configurable up to 99 files.

Operating Temperatur e

0°C to 55°C (–20°C to +70°C sur vivable)

Outputs

Gate violation output on open collector, digital
thickness value output on serial inter face

Dedicated Key Functions

COPY -

Activates outputs to printer, transmit

to data logger, output data logger repor t

ZOOM

- Expands A-Scan display area for

increased scr een resolution

MAGNIFY

- Expands area within gate for

increased A-Scan r esolution in selected area

FREEZE

- Captures cur rent scr een image or

allows continuous capture of echo peaks

LOCK

- Locks against inadver tent change of

parameter values except gain control

dB REF

- Recor ds cur rent gain then allows

changes to be separately noted; amplitude
evaluation then related to refer ence echo
amplitude

dB STEP

- Selects gain incr ements

HOME

- Retur ns instr ument to basic menu

Language

Selectable English, Fr ench, Spanish, Italian,
Por tuguese, Ger man, Dutch, Danish, Finnish,
Nor wegian, Swedish, Russian

Connectors

BNC or Lemo selectable at order

Keypad

Inter national symbols

Batter y Power

6 D-size alkaline or NiCad cell
“L” version: up to 12 hrs operation
“R” version: up to 5.5 hrs operation

Size

9.8"Wx5.25"Dx5.75"H(249mmx133mmx146mm)

Weight

6lbs (2.7kg) with NiCad batteries
3.10lbs (1.4kg) without batteries

USN 50 L & R:

Damping

Selectable: High and Low

Amplifier Bandpass

Br oadband: 0.4 MHz to 10.2 MHz

Memor y

30 dataset memor y locations with rapid clear
functions, memor y flag and A-Scan preview

Optional

DAC/TCG

USN 52 L & R:

Damping

Selectable: 50, 75, 150, 1000 Ohms

Rectification

RF display plus all others

Amplifier Bandpass

Selectable: Br oadband 0.4 MHz to 10.2 MHz

Low: .25 MHz to 4.9 MHz
High: 2.3 MHz to 10.8 MHz
DIN: 1.7 MHz to 8.2 MHz

DAC/TCG

40 dB Dynamic Range with 6 dB/µsec slope

Memor y

USN 52L: 100 Dataset memor y locations
USN 52R: 140 Dataset memor y locations
A-Scan pr eview function, alphanumeric
naming of datasets, director y of all datasets
with memor y flag for filled datasets, rapid
clear function, memo functions

Other Functions

Cur vature cor rection, movable gate in freeze
mode, auto-calibration of material velocity
and pr obe zer o

Outputs

Analog TOF & Amplitude, TTL Go/NoGo, Sync

Optional

DGS, JIS evaluation

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.