Page 2 - ii; ULTRA SYSTEM; OWNER’s Manual; Legal Notices; Disclaimer
` Document # 103357-0004R October, 2008 ii ULTRA SYSTEM OWNER’s Manual Legal Notices Disclaimer Information in this document is subject to change without notice. Consult your Nanoptix Inc. sales representative for information that is applicable and current. Nanoptix Inc. reserves the right to improv...
Page 3 - iii; Information to the User
` Document # 103357-0004R October, 2008 iii ULTRA SYSTEM OWNER’s Manual Information to the User This equipment must be installed and used in strict accordance with the manufacturer's instructions. However, there is no guarantee that interference to radio communications will not occur in a particular...
Page 4 - iv; Table of Contents
` Document # 103357-0004R October, 2008 iv ULTRA SYSTEM OWNER’s Manual Table of Contents Table of Contents .......................................................................................................... iv About the Ultra System ...............................................................
Page 6 - DIP
` Document # 103357-0004R October, 2008 vi ULTRA SYSTEM OWNER’s Manual Figures F IGURE 1: U LTRA S YSTEM .......................................................................... 1 F IGURE 2: U LTRA B OARD VER .1 ................................................................. 2 F IGURE 3: U LTRA ...
Page 7 - vii
` Document # 103357-0004R October, 2008 vii ULTRA SYSTEM OWNER’s Manual Tables T ABLE 1: S PECIFICATIONS .......................................................................... 4 T ABLE 2: DIP S WITCH BANKS 1 & 2 .......................................................... 10 T ABLE 3: DIP S WI...
Page 8 - About the Ultra System; Description of the Ultra System; Figure 1: Ultra System
` Document # 103357-0004R October, 2008 1 ULTRA SYSTEM OWNER’s Manual About the Ultra System 1.1 Description of the Ultra System The Ultra System has been designed to manage small game rooms. With simple non-intrusive connections, the system can be scaled to meet different needs. From remotely clear...
Page 11 - General specifications; Table 1: Specifications
` Document # 103357-0004R October, 2008 4 ULTRA SYSTEM OWNER’s Manual 1.3 General specifications Operating Temperature 0 to 50 C Storage Temperature -40 C to +65 C Operating Relative Humidity 5% to 90% RH at 50C (non-condensing) Communication Interface USB, RS-232C, RS-485 Optional Interface Keyboar...
Page 12 - Ultra Board Controls; This board is powered by the white 2 pin power input harness (; VDC only; Figure 5: Ultra Board Ver.2 Reset
` Document # 103357-0004R October, 2008 5 ULTRA SYSTEM OWNER’s Manual 1.4 Ultra Board Controls 1.4.1 Power source and reset 1.4.1.1 Ultra Board - version 1 This board is powered by the white 2 pin power input harness ( 5 VDC only ). The board is reset by disconnecting and reconnecting this harness. ...
Page 13 - Buttons; Figure 6: Function buttons
` Document # 103357-0004R October, 2008 6 ULTRA SYSTEM OWNER’s Manual 1.4.2 Function Buttons Figure 6: Function buttons • Function Button 1 (RED or SW500): o Pressing while In Run Mode (“PO” on display): Will causes the printer or terminal to display/print a summary of the current DIP switch setting...
Page 14 - Function Buttons 1 and 2
` Document # 103357-0004R October, 2008 7 ULTRA SYSTEM OWNER’s Manual 1.4.3 Function Buttons used in Combination: • Function Buttons 1 and 2 o Pressing simultaneously while In Run Mode (“PO” on display): Will do nothing o Pressing and holding simultaneously for 15 sec while powering up: Will put the...
Page 15 - message
` Document # 103357-0004R October, 2008 8 ULTRA SYSTEM OWNER’s Manual 1.4.4 Display message Figure 7: Display Display message on 2x7 segment LED display: Ad -Multi drop address setup (displayed 1sec while powerring up) Po -Polling: Normal Operation Pr -Printer error: printer not connected or printer...
Page 16 - DIP switches
` Document # 103357-0004R October, 2008 9 ULTRA SYSTEM OWNER’s Manual 1.4.5 DIP switches Note: DIP switch settings can be overridden by software configuration. When an override is in effect, “DIip Switch Over Write ON” will be printed on the power ON status ticket Figure 8: Dip Switches Board Ver. 1...
Page 17 - Ultra Board DIP Switch Settings
` Document # 103357-0004R October, 2008 10 ULTRA SYSTEM OWNER’s Manual Ultra Board DIP Switch Settings DIP Switch 1 (SW503) DIP Switch 2 (SW504) DIP Switch 3 (SW505) Function Value 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 0 0 0 0 0 2 1 0 0 0 0 4 0 1 0 0 0 5 1 1 0 0 0 8 0 0 1 0 0 10 1 0 1 0 ...
Page 19 - LEDs; Figure 10: Status LEDs
` Document # 103357-0004R October, 2008 12 ULTRA SYSTEM OWNER’s Manual 1.4.6 Status LEDs Status LEDs are illuminated when its corresponding game terminal is connected and turned ON. Figure 10: Status LEDs
Page 20 - Note: Modem must be disconnected; Functions Keys
` Document # 103357-0004R October, 2008 13 ULTRA SYSTEM OWNER’s Manual 1.4.7 Advanced configuration – using a PS2 Keyboard and Spill Proof printer For advanced configurations, a PS2 keyboard can be connected to the Ultra Board. DIP switch 7 of bank 3 must be set to ON and DIP switch 8 of bank 3 must...
Page 21 - Advanced configuration – using a terminal software; Figure 12: Configurations using terminal
` Document # 103357-0004R October, 2008 14 ULTRA SYSTEM OWNER’s Manual 1.4.8 Advanced configuration – using a terminal software For advanced configurations, a personal computer along with terminal software (such as Hyper Terminal) can be used to display the configuration menu. The Ultra board must b...
Page 22 - Control Box; Description of the Control Box; Figure 13: Control Box
` Document # 103357-0004R October, 2008 15 ULTRA SYSTEM OWNER’s Manual 2 Control Box 2.1 Description of the Control Box The Control Box is the user interface of the Ultra System. It is used to remotely clear credits and print bookkeeping information. Figure 13: Control Box • LEDs 1 to 6 o ON solid: ...
Page 23 - Pressing these 2 buttons simultaneously will print the; Setting a password on the SOFT METERS:; again to save the value.
` Document # 103357-0004R October, 2008 16 ULTRA SYSTEM OWNER’s Manual 2.2 Buttons used in Combination: • SOFT METERS + BUTTON 1: Pressing these 2 buttons simultaneously will print the last cashout printed. Note: The words “DUPLICATE VOUCHER” will also be printed at two locations on the ticket. • SO...
Page 24 - Spill Proof Printer; Figure 14: Spill Proof Printer
` Document # 103357-0004R October, 2008 17 ULTRA SYSTEM OWNER’s Manual 3 Spill Proof Printer Figure 14: Spill Proof Printer For information on the Spill Proof printer, please refer to the Spill Proof printer manual
Page 25 - Connections and Configuration; Figure 15: Installation overview; Setup for location with a maximum of 6 gaming terminals; Site Controller 1
` Document # 103357-0004R October, 2008 18 ULTRA SYSTEM OWNER’s Manual 4 Connections and Configuration Figure 15: Installation overview 4.1 Setup for location with a maximum of 6 gaming terminals 1. Install the Spill Proof printer on the attendant counter. Connect the control box to Spill Proof prin...
Page 26 - Power up the Ultra Board
` Document # 103357-0004R October, 2008 19 ULTRA SYSTEM OWNER’s Manual 3. Power up the Ultra Board • If you are using Ultra Board version 1: Connect the power input harness’ red wire to +5VC and the Black wire to ground • If you are using Ultra Board version 2: There is no separate power connection ...
Page 27 - Setup for locations with 7 to 36 games; a. Add additional Ultra Boards to the RS485 network in daisy chain; Connect Ultra Board “2” to Ultra Board “1” through the 6 pin; Proof; There are 3 ways to change the Aux Port Parameter:
` Document # 103357-0004R October, 2008 20 ULTRA SYSTEM OWNER’s Manual 4.2 Setup for locations with 7 to 36 games Follow instructions in section 4.1 with the following additions and modifications Note: When more than one Ultra Board is used, the “Remote Cashout” feature is not available 1. Connectio...
Page 28 - Boards; There are 3 ways to change the address; If successful, a report should be printed with the correct
` Document # 103357-0004R October, 2008 21 ULTRA SYSTEM OWNER’s Manual 3. Ultra Boards Note: The following applies to each Ultra Board used in the RS485 network a. For each Ultra Board used: Set DIP switch 6, 7 and 8 of bank 3 to ON. b. Perform a hard reset on each of the Ultra Boards c. On power up...
Page 29 - Troubleshooting the Ultra System; Testing the Ultra Board; Figure 17: Power ON Status Ticket
` Document # 103357-0004R October, 2008 22 ULTRA SYSTEM OWNER’s Manual 5 Troubleshooting the Ultra System 5.1 Testing the Ultra Board Every time the Ultra Board is turned on, a power on ticket will be printed by the Spill printer or displayed on the terminal screen. The resident status ticket lists ...
Page 30 - Testing the Spill Proof Printer; Figure 18: Power ON Status Ticket
` Document # 103357-0004R October, 2008 23 ULTRA SYSTEM OWNER’s Manual 5.2 Testing the Spill Proof Printer The Spill Proof printer’s proper operation can be verified by printing a resident status ticket. During power up, hold the form feed button activated for a minimum of 10 seconds, then release. ...
Page 31 - Communication Ports; Ultra Board; Table 4: 9 Pin RS232 Serial Interface; Pin
` Document # 103357-0004R October, 2008 24 ULTRA SYSTEM OWNER’s Manual 5.3 Communication Ports 5.3.1 Serial (RS232) Interface The table below describes the connection pin-out for the serial Interface (9-pin DB9) Pin Signal Name Ultra Board I/O Terminal I/O Ultra Board Function 1 n/a No connect n/a n...
Page 33 - Media and Supplies Guide; Figure 19: Ultra System Components; Item; Table 7: Ultra System Components
` Document # 103357-0004R October, 2008 26 ULTRA SYSTEM OWNER’s Manual 6 Media and Supplies Guide 6.1 Parts List Figure 19: Ultra System Components Item Part # Description 1 103709-0000R Ultra Board (Main board, daughter board and flat flex cable) 2 103732-0000N Spill Proof Printer kit (includes pow...
Page 34 - Mechanical Drawings
` Document # 103357-0004R October, 2008 27 ULTRA SYSTEM OWNER’s Manual 7 Mechanical Drawings Figure 20: Mechanical Dimensions (in mm) – Board rev.1 Figure 21: Mechanical Dimensions (in mm) – Board rev.2
Page 35 - Maintenance & Cleaning Instructions; MOST 8-LINE TYPE BOARDS
` Document # 103357-0004R October, 2008 28 ULTRA SYSTEM OWNER’s Manual 8 Maintenance & Cleaning Instructions The Ultra Board does not require any maintenance or cleaning. Please refer to the Spill Proof manual for printer maintenance 9 Ultra Board Setting for Common game WHEN SETTING UP THE ULTR...
Page 36 - SETTINGS FOR TRIPLE JACK WITH HANDS COUNT ENABLED
` Document # 103357-0004R October, 2008 29 ULTRA SYSTEM OWNER’s Manual QUARTER PLAY = $5.00 TICKET 20 CREDITS = TICKET SET ULTRA BOARD DIP SWITCH #1 POSITION 1& 7 ON SET T/J DIP SWITCH #3 POSITION 1,2,3 ON DIP SWITCH #5 POSITION 3,4,6,& 7 OFF 5 & 8 ON DIP SWITCH #7 POSITION 1,2,6,7 OFF 5...
Page 38 - 0 Service & Support; United States of America; Technical Support Contact Information
` Document # 103357-0004R October, 2008 31 ULTRA SYSTEM OWNER’s Manual 10 Service & Support 10.1 Returning products back to Nanoptix for repairs (RMA) • Send repair approval request to Nanoptix Inc. please include the following: - Product model # - Serial # - Brief problem description • Ship def...
Page 39 - APPENDIX A: Advanced configuration; : BATTERY BACKED RAM
` Document # 103357-0004R October, 2008 32 ULTRA SYSTEM OWNER’s Manual APPENDIX A: Advanced configuration 1: DATE AND TIME └► 1: SET TIME └► ENTER CURRENT TIME (24 Hr FORMAT, HHMM) └► 2: SET DATE └► ENTER CURRENT DATE (MMDDYY, no punctuation) └► 3: <Time toggles between 12HR and 24 HR format> ...
Page 40 - : SET COIN IN MULTIPLIER
` Document # 103357-0004R October, 2008 33 ULTRA SYSTEM OWNER’s Manual 6: SET COIN IN MULTIPLIER └► 1: SET COIN IN A MULTIPLIER └► PLEASE ENTER WHICH GAME 1-6 or ESC to Cancel └► PLEASE ENTER THE COIN IN A MULTIPLIER for game # <X> or ESC to cancel, Value in decimal + ENTER (0-254max) └► 2: SE...