Emerson 3081FG- Manual

Emerson 3081FG

Emerson 3081FG– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
Page: / 78

Table of Contents:

  • Page 2 – ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!
  • Page 3 – HIGHLIGHTS OF CHANGES
  • Page 5 – Instruction Manual; TABLE OF CONTENTS; AND; Menu Tree for HART Communicator/
  • Page 6 – LIST OF ILLUSTRATIONS
  • Page 7 – LIST OF TABLES
  • Page 9 – PREFACE; NOTE; NOTE TO USERS
  • Page 10 – IMPORTANT; the Operator Manual for instructions.
  • Page 11 – SECTION 1; Bulletin
  • Page 13 – SYSTEM OVERVIEW; is the partial pressure of the oxygen
  • Page 14 – Features
  • Page 15 – the
  • Page 16 – Figure 1-3. Typical System Installation
  • Page 18 – signal; Figure 1-4. Power Supply and Load Requirements
  • Page 19 – SECTION 2; The location of the oxygen probe in
  • Page 20 – SIDE VIEW
  • Page 21 – METAL WALL
  • Page 22 – Figure 2-4. Horizontal Probe Installation; If the optional adapter plates are not
  • Page 23 – Figure 2-5. Adjusting Probe Insertion Depth
  • Page 25 – d. Installing Model 3081 Transmitter; Ensure all components are available to; Figure 2-6. Flat Surface Mounting Dimensional Information
  • Page 26 – Figure 2-7. Pipe Mounting Dimensional Information
  • Page 27 – the display board in place.; Figure 2-8. Display Positioning Assembly
  • Page 29 – Reference air is required for O
  • Page 31 – SECTION 3; a. Verify Mechanical Installation
  • Page 32 – concentration using an IRC or HART Com-; tronics compensates for this effect, the O; Figure 3-3. Proper Calibration Check Gas Flow Rate
  • Page 33 – Tree
  • Page 34 – Figure 3-5. Model 3081 Transmitter Menu Tree
  • Page 35 – Use the keys on the IRC to navigate; ROSEMOUNT
  • Page 36 – PROGRAM MENU; To gain further access to the screens; CODE
  • Page 37 – d. UPPER RANGE VAL
  • Page 38 – f. RESET MAX CELL T
  • Page 39 – used as the high calibration check; k. SET LO BOTTLE O; used as the low calibration check
  • Page 40 – value; Upper Range Limit
  • Page 41 – DIAGNOSTICS MENU; CELL mV; cell mV output. Pressing; CELL mV
  • Page 42 – cell impedance status. GOOD; value. For each calibration check, record; f. PREVIOUS CONSTANT; on the reference and pro-
  • Page 43 – CELL; cell. This value can be reset under; j. SW BUILD NUMBER
  • Page 44 – If the O; value to settle, press NEXT to
  • Page 45 – on the reference and process
  • Page 47 – SECTION 4
  • Page 48 – Ohms; At a convenient point, break the analog
  • Page 53 – From the O
  • Page 55 – SECTION 5; a. Display Board Replacement; the electronics in place.; b. PC Board Stack Replacement; Install replacement PC board stack
  • Page 56 – Block
  • Page 57 – Connect the ribbon cable connector; can cause severe burns.; Note the cell impedance at the electronics.
  • Page 58 – Figure 5-2. Oxygen Probe Terminal Block
  • Page 59 – SECTION 6; PROBE LIFE; Life of the probe is negatively impacted by:
  • Page 60 – Continued degradation of cell slope.; FAULT INDICATIONS; reading is present. When the error is cor-
  • Page 61 – Figure 6-4. Model 3081 Transmitter Terminal Block
  • Page 62 – b. Fault 2, Reversed Thermocouple Active; Allow adequate time for the oxygen
  • Page 64 – Cell Open
  • Page 65 – Cell; The O
  • Page 67 – SECTION 7
  • Page 69 – SECTION 8; Figure and
  • Page 71 – SECTION 9; ACCEPT LOW O
  • Page 72 – SET LO BOTTLE O
  • Page 75 – DRAWINGS AND SCHEMATICS
  • Page 77 – WARRANTY; Limitations of Remedy.; SELLER SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DE-
  • Page 78 – Two-Wire In Situ Oxygen
Loading the manual

Instruction Manual

IB-106-3081 Rev. 1.5
September 2002

http://www.processanalytic.com

Model 3081FG

Two-Wire In Situ
Oxygen Analyzer
(550° to 1600°C)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Emerson 3081FG

Summary

Page 2 - ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!

Emerson Process ManagementRosemount Analytical Inc.Process Analytic Division 1201 N. Main St.Orrville, OH 44667-0901T (330) 682-9010F (330) 684-4434e-mail: [email protected]://www.processanalytic.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, ...

Page 3 - HIGHLIGHTS OF CHANGES

HIGHLIGHTS OF CHANGES Effective June, 1998 Rev. 1.0 Page Summary Page 2-10 Corrected part numbers in Figure 2-9 for Flowmeter and Ref Air Set. Page 3-4 Modified Figure 3-5 to reflect selection of additional faults. Page 3-11 Modified paragraph 3-6a to select additional fault screens. Page 4-4 Update...

Page 5 - Instruction Manual; TABLE OF CONTENTS; AND; Menu Tree for HART Communicator/

Instruction Manual IB-106-3081 Rev. 1.5 September 2002 Rosemount Analytical Inc. A Division of Emerson Process Management i Model 3081FG TABLE OF CONTENTS PREFACE........................................................................................................................ P-1 Definitions ....

Other Emerson Models