Emerson 1F86-344 - User Manual
Emerson 1F86-344 Thermostat – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; BATTERY LOCATION; CHECK THERMOSTAT OPERATION; Fan Operation
- Page 3 – Heating System; HEAT; Cooling System; COOL; CAUTION; WIRING
- Page 4 – CONFIGURATION MENU; Configuration Menu; The Thermostat Buttons and Switches; OPERATION
- Page 5 – TROUBLESHOOTING
- Page 7 – odger
- Page 8 – SOLUCIÓN DE PROBLEMAS; OPERACIÓN
- Page 9 – Los botones e interruptores del termostato; MENÚ DE CONFIGURACIÓN; Figura 8. Pantalla, botones e interruptores del termostato
- Page 10 – Sistema de calefacción; AT; Sistema de refrigeración; INST ALA; No se requiere la cone
- Page 11 – RETIRE EL TERMOST
- Page 12 – T er; INSTRUCCIONES DE INST; PRECAUCIONES
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technology
of a solid-state microcomputer to provide precise temperature
control.
Features:
• Simultaneous heat and cool setpoint storage
• Pre-set temperature control
• Backlit display
• LCD continuously displays setpoint and room temperature
• °F/°C convertibility
• Temperature range 45° to 90°F
• RC, RH, C, W, Y, G , O and B terminals
• Optional C terminal (Dual Power option)
• B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
• Setpoint storage in case of power loss
• 2 "AA" alkaline batteries included
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load
(All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
APPLICATIONS
For use with:
•
Standard heat/cool or heat only systems
•
Electric heat systems
•
Gas or oil fired systems
•
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
•
Hydronic (hot water or steam) systems
•
Single-stage heat pump systems (no auxiliary heat)
•
Millivolt systems
DO NOT USE WITH:
•
Multi-stage systems
•
Systems exceeding 30 VAC and 1.5 amps
•
3-wire zoned hydronic heating systems
1F86-344
Non-Programmable Electronic Digital Thermostat
PART NO. 37-6585C
Replaces 37-6585B
1123
INSTALLATION AND
OPERATION INSTRUCTIONS
PRECAUTIONS
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contrac
-
tor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
WARNING
!
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the sys-
tem shall conform to Class II circuits per the NEC code.
Operator: Save these instructions for future use!
www.white-rodgers.com
www.emersonclimate.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wal...
3 RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 5. Typical wiring diagram for heat/cool, 5-wire, two-transformer systems HEATING TRANSFORMER Heating System Fan Relay CoolingSystem RC 24 VAC 120 VAC Hot Neutral COOLING TRANSFORMER O B C‡ RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTE...
4 CONFIGURATION MENU The configuration menu allows you to set certain thermostat op - erating characteristics to your system or personal requirements. Move SYSTEM switch to the OFF position, then press and at the same time to enter the configuration menu. The display will show the first item in the ...