Eaton MN05401014E - Manual

Eaton MN05401014E

Eaton MN05401014E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Programming routine; Polarity of the inputs; CHS Controls AB
  • Page 3 – Polarity of the inputs:; Terminal assignment; Standard
  • Page 5 – español; INP
  • Page 6 – Rutina de programación; Polaridad de las entradas
  • Page 7 – Características técnicas; EEPROM
  • Page 8 – La entrega incluye
  • Page 9 – français
  • Page 10 – Routine de programmation; Polarité des entrées
  • Page 11 – Caractéristiques techniques
  • Page 12 – La livraison comprend
  • Page 13 – deutsch; Warnhinweise; pa ra me ter
  • Page 14 – Programmierroutine; Polarität der Eingänge
  • Page 15 – Polarität der Eingänge:; Schalttafelgehäuse
  • Page 16 – Schalttafelausschnitt:; Einbaurahmen; für Einbauquerschnitt 50 x 25 mm
  • Page 17 – italiano; Istruzioni per la sicurezza e; Regolazione dei parametri di
  • Page 18 – Routine di programmazione; Polarità delle entrate
  • Page 19 – Caratteristiche tecniche
  • Page 20 – La consegna include
Loading the manual

MN05401014E

1

español

english

français

deutsch

italiano

Operating Instructions
Electronic Totalizer
E5024E0402

1. Description

• 6-digit adding counter with RESET function
• Red LED display, character height 8 mm

[0.31 in.]

• Display range 0 – 999 999
• Lead zero blanking
• Programming via two setting keys on the front

side

• During programming, the display guides the

user with text prompts

1.1 Safety instructions and warnings

Only use this display

– according to its intended purpose
– if its technical condition is perfect
– adhering to the operating

instructions and the general
safety instructions.

1.2 General safety instructions

1. Before carrying out any installation or mainte-

nance work, make sure that the power supply
of the digital display is switched off.

2. Only use this digital display in a way accord-

ing to its intended purpose:
If its technical condition is perfect.
Adhering to the operating instructions and the
general safety instructions.

3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in

areas with risks of explosion and in the
branches excluded by the standard EN 61010
Part 1.

5. The digital display should only operated if it

has been correctly mounted in a panel, in
accordance with the chapter “Technical data”.

1.3 Use according to the intended

purpose

The digital display may be used only as a panel-
mounted device. Applications of this product may
be found in industrial processes and controls, in
manufacturing lines for the metal, wood, plastics,
paper, glass, textile and other processing indus-
tries.
Over-voltages at the terminals of the digital dis-
play must be kept within the limits in Category II.

If the digital display is used to monitor machines
or processes in which, in case of a failure of the
device or an error made by the operator, there
might be risks of damaging the machine or
causing accidents to the operators, it is your
responsibility to take appropriate safety
measures.

2. Inputs

INP

Dynamic count input.

RESET

Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero.

3. Setting of the operating pa ra me ters

a. Press both front side keys and switch on the

supply voltage or, if the supply voltage is
already on, press both keys simultaneously
for 5 s.

b. The display shows

c. After releasing the keys, the display shows

!

MN05401014E:MN05401014E 2/9/07 1:26 PM Page 1

CHS Controls AB

Tel +46 42 38 61 00, Fax +46 42 38 61 29

[email protected] www.chscontrols.se

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Programming routine; Polarity of the inputs; CHS Controls AB

2 MN05401014E 30 Hz filter off (fmax) 30 Hz filter on 4.2 Switching on the 30 Hz filter (INP) 4.3 Decimal point setting The decimal point determinesthe way of displaying thecount values. It does notaffect counting. 0 no decimal place0.0 one decimal place0.00 two decimal places0.000 three decimal pla...

Page 3 - Polarity of the inputs:; Terminal assignment; Standard

MN05401014E 3 english 5. Technical data Supply voltage: DC power supply: 10 – 30V DC/max. 40 mA Display: 6 digits, red 7 segmentLED display, height 8 mm[0.31 in.] Data retention: EEPROM Polarity of the inputs: Programmable, npn or pnp(sinking or sourcing) for allinputs Input resistance: appr. 5 kOhm...

Page 5 - español; INP

MN05401014E 5 español 1. Descripción • Contador totalizador con 6 décadas y función RESET • Pantalla de LED rojos, altura 8 mm• Intervalo de visualización 0..999 999 • Supresión de los ceros en cabeza• Programación con dos teclas de la cara delantera • Programación guiada por mensajes en la pantalla...