Page 2 - TABLE OF CONTENTS; SAFETY GUIDELINES - DEFINITIONS
2—ENG MGP-SL10120H-2A TABLE OF CONTENTS Page Page CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY ...
Page 3 - RISK OF BURSTING; RISK OF EXPLOSION OR FIRE; HAZARD; IMPORTANT SAFETY INSTRUCTIONS
3—ENG MGP-SL10120H-2A RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK. IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE,CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS W...
Page 4 - RISK FROM FLYING OBJECTS; RISK TO BREATHING
4—ENG MGP-SL10120H-2A WHAT CAN HAPPEN HOW TO PREVENT IT RISK FROM FLYING OBJECTS THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT, CHIPS, LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED , RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY. ALWAYS WEAR ANSI Z87....
Page 5 - RISK FROM MOVING PARTS
5—ENG MGP-SL10120H-2A MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING. ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COM-PRESSOR WITH PROTECTIVE SHROUDS REMOVED CANEXPOSE YOU TO M...
Page 6 - DUTY CYCLE
6—ENG MGP-SL10120H-2A Refer to cover page for the specifications of your compressor. Use only a fuse or circuit breaker that is the same ratingas the branch circuit the air compressor is operated on. If the compressor is connected to a circuit protected by fuses,use dual element time delay fuses, as...
Page 8 - DESCRIPTION OF OPERATION
8—ENG MGP-SL10120H-2A DESCRIPTION OF OPERATION to restart freely. When the motor stops running, air willbe heard escaping from the valve for a few seconds. Noair should be heard leaking when the motor is running. Pressure Switch: Pressure Switch: Pressure Switch: Pressure Switch: Pressure Switch: Th...
Page 9 - INSTALLATION AND BREAK-IN PROCEDURES; Horizontal Units; Location of the Air Compressor
9—ENG MGP-SL10120H-2A INSTALLATION AND BREAK-IN PROCEDURES This compressor should be permanently mounted inplace on a level floor. Operate the air compressor in aclean, dry and well ventilated area. The air intake filtermust be kept clear of obstructions which could reduce airdelivery of the air com...
Page 10 - Wiring Instructions; Voltage and Circuit Protection; Wiring of Compressor Units
10—ENG MGP-SL10120H-2A INSTALLATION AND BREAK-IN PROCEDURES Wiring Instructions If your compressor unit is not equipped with a plug-in typepower cord, perform electrical wiring according to thefollowing instructions: IMPROPER ELECTRICAL GROUNDING CANRESULT IN A RISK OF ELECTRICAL SHOCK.WIRING SHOULD...
Page 11 - Lubrication and Oil
11—ENG MGP-SL10120H-2A INSTALLATION AND BREAK-IN PROCEDURES Break-In Procedures Additional Regulators andControls Multi-viscosity motor oils like 10W30, shouldnot be used in an air compressor. Theyleave carbon deposits on critical compo-nents, thus reducing performance and com-pressor life. Use air ...
Page 12 - Piping
12—ENG MGP-SL10120H-2A INSTALLATION AND BREAK-IN PROCEDURES Piping Note Note Note Note Note For underground installation, bury airlines below the frost line and avoidpockets where condensation can gatherand freeze. Apply pressure before un-derground lines are covered to makesure all pipe joints are ...
Page 13 - OPERATING PROCEDURES
13—ENG MGP-SL10120H-2A OPERATING PROCEDURES 1. Before attaching an air hose or accessory, make sure the outlet valve is in the closed position. On units equippedwith a pressure switch lever make sure the switch is in theOFF position. Compressed air from the outfit may containwater condensation and o...
Page 14 - MAINTENANCE; Routine Maintenance Schedule
14—ENG MGP-SL10120H-2A MAINTENANCE UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. DURING MAINTENANCE, YOU COULD BEEXPOSED TO VOLTAGE SOURCES, COMPRESSED AIR OR MOVING PARTS. PERSONAL INJURIESCAN OCCUR. DISCONNECT POWER SOURCE AND BLEED OFF ALL AIR TANK PRESSURE BEFOREDOING ANY MAINTENANCE OR REPAIR. NE...
Page 15 - SERVICE INSTRUCTIONS; Oil - Checking and Changing
15—ENG MGP-SL10120H-2A SERVICE INSTRUCTIONS A dirty air filter will not allow the compressor to operateat full capacity. Before you use the compressor, checkthe air filter to be sure it is clean. If it is dirty, replace itwith a new filter. Air Filter - Inspection andReplacement NOTE NOTE NOTE NOTE ...
Page 16 - Adjusting Belt Tension
16—ENG MGP-SL10120H-2A Adjusting Belt Tension Adjust belt tension as described below. For compressors with a motor slide mount, adjust belttension as follows: 1. Slide motor away from compressor until desired tension is obtained. On two stage compressors, the belt should deflect1/2" at midway be...
Page 17 - Additional Service; STORAGE OF COMPRESSOR OUTFIT
17—ENG MGP-SL10120H-2A SERVICE INSTRUCTIONS Motor Pulley and FlywheelAlignment 1. Remove outer beltguard - To remove, loosen and remove beltguard screws located at top of beltguard.Insert a flat bladed screwdriver and pry beltguardapart. 2. Place a straight edge along the outside face of the compres...
Page 18 - TROUBLESHOOTING GUIDE
18—ENG MGP-SL10120H-2A CAUSE CORRECTION PROBLEM TROUBLESHOOTING GUIDE PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIRSOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, DISCONNECTPOWER SOURCE FROM THE COMPRESSOR AND BLEED OFF ALL TANK AIR PRESSURE. Exce...
Page 21 - PROBLEM
21—ENG MGP-SL10120H-2A TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Too many motor starts per hour. Consult Service Center. Check electrical hookup and installation data or con-sult electrician. Improper wiring gauge.Incorrect voltage. Water in pump crankcase; oilappears milky in color. Liquid wat...
Page 22 - COMPRESSOR DIAGRAM
Page 23 - COMPRESSOR PARTS LIST; Key; Part Not Shown
23—ENG MGP-SL10120H-2A COMPRESSOR PARTS LIST Key Part No. Number Description 1 Z-BAL-T59S PUMP ASSEMBLY 2 Z-MO-9082 MOTOR 3 Z-D20596 PRESSURE SWITCH ASSEMBLY 4 TIA-4200 SAFETY VALVE 5 Z-GA-360 PRESSURE GAUGE 6 SSV-6-B BALL VALVE 7 AC-0485 BELTGUARD BRACKET (2) 8 PU-2906 MOTOR PULLEY 9 BT-316 BELT (2...
Page 24 - COMPRESSOR PUMP DIAGRAM
Page 25 - PARTS LIST; K e y
25—ENG MGP-SL10120H-2A PARTS LIST K e y Part No. Number Description 1 BAL-7061400 HEAD 2 BAL-7040050 VALVE PLATE ASSEMBLY 3 BAL-9049011 SAFETY VALVE, AFTERCOOLER 4 AC-0415 FILTER ASSEMBLY 5 AC-0583 FLYWHEEL 6 BAL-1000112 OIL BREATHER ASSEMBLY 7 BAL-9022003 OIL SIGHT GLASS 8 BAL-1000506 OIL PLUG 1/2&...
Page 26 - SERVICE NOTES
Page 27 - LIMITED WARRANTY
27—ENG MGP-SL10120H-2A LIMITED WARRANTY DeVilbiss Air Power Company warrants to the original purchaser who uses the product in a consumer application (personal, residential or household usage) that all products covered under this warranty are free from defects in material andworkmanship for one year...
Page 28 - WARRANTY; Call our
OWNERS MANUAL FOR TWO-STAGE AIR COMPRESSOR Model No. L10120H2-2 DeVilbiss Air Power Company • 213 Industrial Dr. • Jackson, TN 38301-9615 WARRANTY This product is covered by the DeVilbissone year limited warranty. The warrantycan be found in this General Manual oris available upon request. Attach Sa...
Page 29 - Tabla De Especificaciones; Modelo
MANUAL DEL OPERADOR PARA COMPRESOR DE AIRE DE DOS ETAPAS Modelo No. L10120H2-2 Tabla De Especificaciones Modelo L10120H2-2 Potencia 10 HP Voltaje/Ciclaje/Fases 240/480V/60 Hz / trifásico Requerimiento mínimo del ramal del circuito 30 AMP * Tipo de fusible "De acción retardada" Capacidad del ...
Page 30 - TABLA DE CONTENIDOS; DEFINICIONES DE NORMAS DE SEGURIDAD; PELIGRO; ADVERTENCIA; PRECAUCION
2—SP MGP-SL10120H-2A TABLA DE CONTENIDOS Página PAUTAS DE SEGURIDAD ..................................... 2 TABLA DE ADVERTENCIAS ................................. 3-5 ESPECIFICACIONES .............................................. 6 GLOSARIO ............................................................
Page 31 - RIESGO DE EXPLOSIÓN; RIESGO DE EXPLOSIÓN O INCENDIO
3—SP MGP-SL10120H-2A RIESGO DE EXPLOSIÓN PARA LOS CONTACTOS ELÉCTRICOS ES NORMAL LA EXISTENCIA DE CHISPAS ENTRE EL MOTOR Y EL INTERRUPTOR A PRESIÓN. SI LAS CHISPAS ELÉCTRICAS PROVENIENTES DEL COMPRESOR TOMARAN CONTACTO CON EMANACIONES DE MATERIALES INFLAMABLES, ELLOSPODRÍAN ARDER ORIGINANDO INCENDIO...
Page 32 - RIESGO DE OBJETOS ARROJADOS POR EL AIRE.; RIESGO DE INHALACIÓN
4—SP MGP-SL10120H-2A ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? RIESGO DE OBJETOS ARROJADOS POR EL AIRE. EL CHORRO DE AIRE COMPRIMIDO PUEDE CAUSAR DAÑOS SOBRE LOS TEJIDOS BLANDOS DE LA PIEL EXPUESTA, Y PUEDE PROPULSAR SUCIEDAD, ASTILLAS, PARTÍCULAS SUELTAS Y PEQUEÑOS OBJETOS A ALTA VELOCIDAD, OCASIONANDO...
Page 33 - RIESGO DE PARTES MÓVILES
5—SP MGP-SL10120H-2A PARTES MOVIBLES TALES COMO LA POLEA, EL VOLANTE Y LA CORREA PODRÍAN SER LA CAUSA DE SERIAS LESIONES SI ELLAS ENTRARAN EN CONTACTO CON USTED O SUS ROPAS. INTENTAR OPERAR EL COMPRESOR CON SUS PARTES DAÑADAS OFALTANTES, O LA REPARACIÓN DEL COMPRESOR CON SUS PROTECCIONESREMOVIDAS, P...
Page 34 - CICLO DE TRABAJO
6—SP MGP-SL10120H-2A ESPECIFICACIONES Para ver las especificaciones del compresor, referirse a la carátula de este manual. Usar sólo un fusible o interruptor de circuito delmismo amperaje que el circuito en el cual está operando el compresor de aire. Si el compresor de aire está conectado a un circu...
Page 36 - DESCRIPCIÓN DE LA OPERACIÓN
8—SP MGP-SL10120H-2A Válvula de Drenaje: La válvula de drenaje está ubicada en la base del tanque de aire y se usa después de cada aplicaciónpara drenar la condensación. Interruptor "ON/Auto-OFF": Colocar este interruptor en la posición de "ON" para activar el interruptor de presión,...
Page 37 - Ubicación del Compresor de Aire; PROCEDIMIENTOS PARA LA INSTALACIÓN Y ASENTAMIENTO; Unidades Horizontales
9—SP MGP-SL10120H-2A Ubicación del Compresor de Aire LA BOMBA NO PROVEE SUFICIENTEE S TA B I L I D A D N I S O P O R T E PA R ALEVANTAR LA UNIDAD. SI SE TIENE QUET R A N S P O R TA R , L E V A N TA R D E LTANQUE. Este compresor debe montarse permanentemente en un lugardonde el piso esté nivelado. Op...
Page 38 - Instrucciones para el Cableado; Voltaje y Protección del Circuito; Cableado de las Unidades Compresoras
10—SP MGP-SL10120H-2A Instrucciones para el Cableado Si el compresor de aire no está provisto de un cordón desuministro eléctrico con enchufe, hacer la instalación eléctricade acuerdo a las siguientes instrucciones: L A C O N E X I Ó N I N A P R O P I A D A A T I E R R APUEDE RESULTAR EN CHOQUE ELÉC...
Page 39 - Procedimientos para el Asentamiento; Controles y Reguladores Adicionales; Ensamblaje del Filtro de Aire
11—SP MGP-SL10120H-2A Procedimientos para el Asentamiento Si no se observan las instrucciones para elasentamiento abajo indicadas, se puedencausar serios daños. Los Procedimientos para el Asentamiento se requieren en lassiguientes circunstancias: A. Cuando se pone en servicio un nuevo compresor.B. C...
Page 40 - Tuberías
12—SP MGP-SL10120H-2A Tuberías L o s t u b o s d e p l á s t i c o o P V C n o e s t á ndiseñados para usarse con aire comprimido.A pesar que las especificaciones de presiónsean las adecuadas, los tubos de plásticopueden reventar con la presión del aire. Usarúnicamente tubos de metal o líneas paradi...
Page 41 - PROCEDIMIENTOS PARA OPERAR
13—SP MGP-SL10120H-2A 1. Antes de conectar una manguera neumática o accesorio, asegurarse que la válvula de salida esté cerrada. Enunidades equipadas con una palanquita de interrupción depresión, asegurarse que el interruptor esté en la posiciónde "OFF" (apagado). El aire comprimido provenie...
Page 42 - Programa de Mantenimiento Rutinario; MANTENIMIENTO
14—SP MGP-SL10120H-2A LA UNIDAD ENTRA EN FUNCIONAMIENTO AUTOMÁTICAMENTE CUANDO ESTÁ ACTIVADA EN "ON". AL HACERLEMANTENIMIENTO USTED PUEDE QUEDAR EXPUESTO A LAS FUENTES DE VOLTAJE, PARTES MOVIBLES OAIRE COMPRIMIDO. PUEDEN OCURRIR DAÑOS PERSONALES. ANTES DE INTENTAR HACER REPARACIONESO CUALQUI...
Page 43 - Aceite - Inspección y Cambio; INSTRUCCIONES PARA EL SERVICIO; Tabla de Aceite
15—SP MGP-SL10120H-2A Filtro de Aire - Inspección yReemplazo NOTA M a n t e n e r e l f i l t r o d e a i r e l i m p i o e n t o d omomento. No operar el compresor sin el filtrode aire. Un filtro sucio impedirá que el compresor opere a máximacapacidad. Antes de usar el compresor, verificar que el f...
Page 45 - Servicio Adicional; INSTRUCCIONES PARA EL ALMACENAJE DEL COMPRESOR
17—SP MGP-SL10120H-2A Regulación de la Tensiónde la Correa R e g u l a r l a t e n s i ó n d e l a c o r r e a c o m o s e d e s c r i b e acontinuación. En compresores con motor en montaje deslizante, regular latensión de la correa como se indica a continuación: 1. Deslizar el motor alejándolo del ...
Page 46 - GUÍA PARA DIAGNÓSTICO DE PROBLEMAS
18—SP MGP-SL10120H-2A GUÍA PARA DIAGNÓSTICO DE PROBLEMAS AL HACER EL MANTENIMIENTO PUEDEN QUEDAR EXPUESTAS LAS FUENTES DE VOLTAJE, PARTESMOVIBLES O FUENTES DE AIRE COMPRIMIDO. PUEDEN CAUSAR DAÑOS PERSONALES. ANTES DEINTENTAR HACER REPARACIONES, DESCONECTAR EL SUMINISTRO DE ENERGÍA AL COMPRESOR YALIV...
Page 50 - DIAGRAMA DEL COMPRESOR
Page 51 - LISTA DE PARTES DEL COMPRESOR
23—SP MGP-SL10120H-2A LISTA DE PARTES DEL COMPRESOR 1 Z-BAL-T59S BOMBA 2 Z-MO-9082 MOTOR 3 Z-D20596 INTERRUPTOR DE PRESIÓN 4 TIA-4200 VÁLVULA DE SEGURIDAD 5 Z-GA-360 MEDIDOR DE PRESIÓN 6 SSV-6-B VÁLVULA DE BOLA 7 AC-0485 SOPORTE DEL PROTECTOR DE CORREA (2) 8 PU-2906 POLEA DEL MOTOR 9 BT-316 CORREA (...
Page 52 - DIAGRAMA DE LA BOMBA DEL COMPRESOR
24—SP MGP-SL10120H-2A DIAGRAMA DE LA BOMBA DEL COMPRESOR
Page 53 - LISTA DE PARTES DE LA BOMBA COMPRESORA; NÚMERO; VÁLVULA DE SEGURIDAD DEL POSTENFRIADOR
25—SP MGP-SL10120H-2A LISTA DE PARTES DE LA BOMBA COMPRESORA NÚMEROEN NÚMERO DIAGRM. DE PARTE DESCRIPCIÓN 1 BAL-7061400 CONJUNTO DE LA CULATA 2 BAL-7040050 ENSAMBLAJE DE LA PLACA DE LA VÁLVULA 3 BAL-9049011 VÁLVULA DE SEGURIDAD DEL POSTENFRIADOR 4 AC-0415 ENSAMBLAJE DEL FILTRO 5 AC-0583 POLEA VOLANT...
Page 54 - NOTAS DE SERVICIO
Page 55 - GARANTÍA LIMITADA
27—SP MGP-SL10120H-2A DeVilbiss Air Power Company garantiza al comprador original que utilice este producto para uso personal (uso personal, residencial o doméstico) que todos los productos cubiertos bajo esta garantía están libres de defectos enmateriales y mano de obra durante un año, a partir de ...
Page 56 - Llamar gratis al; Adherir la factura de compra aquí.
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 MANUAL DEL OPERADOR PARA Compresor de Aire de dos Etapas. Modelo No. L10120H2-2 Llamar gratis al 1-800-888-2468 para saber la ubicación del Centro de Servicio Autorizado más cercano para ordenar repuestos o solicitarreparaci...