Table of Contents:
- Page 2 – TABLE OF CONTENTS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls
- Page 3 – Continued; PRODUCT IDENTIFICATION; SAFETY INFORMATION; Piezo Ignitor
- Page 4 – LOCAL CODES; The hood is located in the packing on; UNPACKING; CAUTION: Do not remove the data plates attached; PRODUCT FEATURES; OPERATION
- Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
- Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; WARNING: If the area in which the heater may be
- Page 7 – WARNING: A qualified service person must in-; INSTALLATION; Your fireplace is designed to be used in zero clearance; Figure 5 - Installing Hood to Firebox; CHECK GAS TYPE
- Page 8 – If you are recessing the firebox in a wall, do not; INSTALLATION CLEARANCES; Figure 8 - Minimum Clearance for Combustible to Wall; *Minimum 16 inches from Side Wall; MINIMUM CLEARANCE TO
- Page 9 – Figure 10 - Installing Cabinet Mantel; CONVENTIONAL FIREPLACE INSTALLATION; Bushing may be; Figure 9 - Placing Hearth Base Accessory Against Wall; Electrical Outlet; Figure 11 - Location of Nailing Flanges
- Page 10 – WARNING: A qualified electrician must connect; Figure 13 - Rough Opening for Installing in Wall; Nailing Flanges
- Page 11 – Blower; Figure 17 - Connecting Duplex Outlet; Shield
- Page 12 – WARNING: A qualified service person must con-; Mantel Clearances for Built-In Installation; Figure 20 - Minimum Mantel Clearances for Built-In Installation; Installation Items Needed; • equipment shutoff valve *
- Page 13 – Figure 22 - Gas Connection; Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; Sediment Trap; • Phillips screwdriver; CONNECTING FIREPLACE TO GAS SUPPLY; CAUTION: Do not pick up log base assembly by
- Page 14 – Figure 23 - Removing Log Base Assembly From Fireplace; WARNING: Test all gas piping and connections; Pressure Testing gas Supply Piping system; Correct all leaks at once.; CHECKING GAS CONNECTIONS
- Page 15 – INSTALLING LOGS; Figure 25 - Equipment Shutoff Valve; Open; Pressure Testing Fireplace Gas Connections; Make sure control knob of fireplace is in the OFF position.; Figure 27 - Checking Gas Joints for Propane/LP; Figure 26 - Checking Gas Joints for Natural Gas; Gas Control Valve
- Page 16 – Make sure; WARNING: You must operate this fireplace with
- Page 17 – Installing Remote Receiver Unit; INSTALLING 9-VOLT BATTERIES; Installing 9-Volt Battery in Receiver
- Page 18 – FOR YOUR SAFETY; WARNING: Burner will come on automatically; Control Knob; CAUTION: Do not try to adjust heating levels by; LIGHTING INSTRUCTIONS; OPERATING FIREPLACE
- Page 19 – WARNING: Make sure the selector switch is in the; TO TURN OFF GAS TO APPLIANCE; Shutting Off Fireplace; Set selector switch; Shutting Off Burner Only (pilot stays lit); MANUAL LIGHTING PROCEDURE; Pilot Burner; Thermostat Control Operation; Do not leave the selector switch in the RE-; Flame Adjustment Knob
- Page 20 – Figure 43 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; INSPECTING BURNERS; GHRC Series Operation:; The hand-held remote control unit must; Note for GA3700T Series Only:; OPTIONAL BLOWER OPERATION
- Page 21 – CLEANING AND MAINTENANCE; BURNER PRIMARY AIR HOLES; WARNING: If yellow tipping occurs, your fireplace; BURNER FLAME PATTERN; If burner flame pattern is incorrect, as shown in Figure 46; Figure 45 - Correct Burner Flame Pattern; Yellow Tipping; Figure 46 - Incorrect Burner Flame Pattern; WARNING: Turn off fireplace and let cool before; Blow air through the ports/slots and holes in the burner.; Figure 47 - Injector Holder On Outlet Burner Tube
- Page 22 – Figure 48 - Pilot Inlet Air Hole; SPECIFICATIONS; WIRING DIAGRAM; Note
- Page 23 – TROUBLESHOOTING; WARNING: Turn off and let; POSSIBLE CAUSE
- Page 24 – OBSERVED PROBLEM
- Page 25 – IMPORTANT; REMEDY
- Page 26 – ILLUSTRATED PARTS BREAKDOWN
- Page 27 – PARTS LIST; KEY
- Page 29 – PART NUMBER
- Page 34 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010
- Page 35 – LAMINATE TRIM FOR HEARTH OR MANTEL; For all models. Included with accessory mantels.; Hearth Base Trim
- Page 36 – REPLACEMENT PARTS; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE
- Page 37 – • ACCESSORIES; OWNER'S REGISTRATION FORM
- Page 38 – Postage
- Page 39 – NOTES
- Page 40 – NOT A UPC; LIMITED WARRANTY; For information about this warranty write:; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model
TM
UNVENTED (VENT-FREE) GAS FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
This appliance may be installed in an aftermarket,* manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use
any phone in your building.
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
•
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
q u a l i f i e d i n s t a l l e r , s e r v i c e
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Air for
Combustion and Ventilation sec-
tion on page 4 of this manual.
VYGF33PRB, VYGF33NRB, FPVF33PRA (Millivolt) and FPVF33NRA (Millivolt)
REMOTE-READY GAS FIREPLACE SYSTEMS
Shown with optional cabinet
mantel, hearth base, and trim
accessories.
Patent Pending
;;;;;;
;;;;;;
;;;;;;
;;;;;;
;;;;;;
;;;;;;
;;;;;;
;;;;;;
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
QQQQQQ
¢¢¢¢¢¢
¢¢¢¢¢¢
¢¢¢¢¢¢
¢¢¢¢¢¢
¢¢¢¢¢¢
¢¢¢¢¢¢
¢¢¢¢¢¢
¢¢¢¢¢¢
;;
;;
¢¢
¢¢
;;;;;;;;;
;;;;;;;;;
;;;;;;;;;
QQQQQQQQQ
QQQQQQQQQ
QQQQQQQQQ
¢¢¢¢¢¢¢¢¢
¢¢¢¢¢¢¢¢¢
¢¢¢¢¢¢¢¢¢
Shown with optional cabinet
mantel and hearth base
accessories.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 PRODUCT IDENTIFICATION .......
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION Continued PRODUCT IDENTIFICATION Figure 2 - Fireplace (VYGF33PRB Shown) 1. This appliance is only for use ...
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODES Install and use fireplace with care. Follow all local codes. In theabsence of local codes, use the latest edition o...