Page 2 - TABLE OF CONTENTS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 PRODUCT IDENTIFICATION .......
Page 3 - Continued; PRODUCT IDENTIFICATION; SAFETY INFORMATION; Piezo Ignitor
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION Continued PRODUCT IDENTIFICATION Figure 2 - Fireplace (VYGF33PRB Shown) 1. This appliance is only for use ...
Page 4 - LOCAL CODES; The hood is located in the packing on; UNPACKING; CAUTION: Do not remove the data plates attached; PRODUCT FEATURES; OPERATION
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODES Install and use fireplace with care. Follow all local codes. In theabsence of local codes, use the latest edition o...
Page 5 - Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 5 5 PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSIZ223.1/NFPA 54, Section 5.3, Air f...
Page 6 - Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; WARNING: If the area in which the heater may be
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 6 AIR FOR COMBUSTION ANDVENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from...
Page 7 - WARNING: A qualified service person must in-; INSTALLATION; Your fireplace is designed to be used in zero clearance; Figure 5 - Installing Hood to Firebox; CHECK GAS TYPE
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 7 7 INSTALLATION NOTICE: This heater is intended for use as supple-mental heat. Use this heater along with your primaryheating sy...
Page 8 - If you are recessing the firebox in a wall, do not; INSTALLATION CLEARANCES; Figure 8 - Minimum Clearance for Combustible to Wall; *Minimum 16 inches from Side Wall; MINIMUM CLEARANCE TO
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 8 INSTALLATION Continued INSTALLATION Assembling and Attaching Optional Brass TrimInstallation Clearances Figure 7 - Attaching Br...
Page 9 - Figure 10 - Installing Cabinet Mantel; CONVENTIONAL FIREPLACE INSTALLATION; Bushing may be; Figure 9 - Placing Hearth Base Accessory Against Wall; Electrical Outlet; Figure 11 - Location of Nailing Flanges
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 9 9 INSTALLATION Continued INSTALLATION Conventional Fireplace Installation Figure 10 - Installing Cabinet Mantel CONVENTIONAL FI...
Page 10 - WARNING: A qualified electrician must connect; Figure 13 - Rough Opening for Installing in Wall; Nailing Flanges
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 10 INSTALLATION Continued INSTALLATION Built-In Fireplace Installation Actual Framing Height 32 3 / 8 " 33" Front Width 3...
Page 11 - Blower; Figure 17 - Connecting Duplex Outlet; Shield
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 11 11 1. Frame in rough opening. Use dimensions shown in Figure 16for the rough opening. 2. If using blower, install wiring and p...
Page 12 - WARNING: A qualified service person must con-; Mantel Clearances for Built-In Installation; Figure 20 - Minimum Mantel Clearances for Built-In Installation; Installation Items Needed; • equipment shutoff valve *
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 12 WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pres-sure regulator. WARNING: A...
Page 13 - Figure 22 - Gas Connection; Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; Sediment Trap; • Phillips screwdriver; CONNECTING FIREPLACE TO GAS SUPPLY; CAUTION: Do not pick up log base assembly by
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 13 13 INSTALLATION Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace to Gas Supply Figure 22 - Gas Connect...
Page 14 - Figure 23 - Removing Log Base Assembly From Fireplace; WARNING: Test all gas piping and connections; Pressure Testing gas Supply Piping system; Correct all leaks at once.; CHECKING GAS CONNECTIONS
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 14 INSTALLATION Continued Figure 23 - Removing Log Base Assembly From Fireplace NOTICE: Most building codes do not permit con-cea...
Page 15 - INSTALLING LOGS; Figure 25 - Equipment Shutoff Valve; Open; Pressure Testing Fireplace Gas Connections; Make sure control knob of fireplace is in the OFF position.; Figure 27 - Checking Gas Joints for Propane/LP; Figure 26 - Checking Gas Joints for Natural Gas; Gas Control Valve
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 15 15 CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates containimportant warranty and ...
Page 16 - Make sure; WARNING: You must operate this fireplace with
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 16 INSTALLATION Continued It is very important to install the logs exactly as instructed. Do notmodify logs. Only use logs suppli...
Page 17 - Installing Remote Receiver Unit; INSTALLING 9-VOLT BATTERIES; Installing 9-Volt Battery in Receiver
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 17 17 INSTALLATION Optional Wireless Hand-Held Remote Control Accessories Installing 9-Volt Batteries INSTALLATION Continued OPTI...
Page 18 - FOR YOUR SAFETY; WARNING: Burner will come on automatically; Control Knob; CAUTION: Do not try to adjust heating levels by; LIGHTING INSTRUCTIONS; OPERATING FIREPLACE
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 18 O F F PIL O T O N L O I H AUTOOFFON WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fir...
Page 19 - WARNING: Make sure the selector switch is in the; TO TURN OFF GAS TO APPLIANCE; Shutting Off Fireplace; Set selector switch; Shutting Off Burner Only (pilot stays lit); MANUAL LIGHTING PROCEDURE; Pilot Burner; Thermostat Control Operation; Do not leave the selector switch in the RE-; Flame Adjustment Knob
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 19 19 WARNING: Make sure the selector switch is in the OFF position when you are away from home for longperiods of time. Fireplac...
Page 20 - Figure 43 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; INSPECTING BURNERS; GHRC Series Operation:; The hand-held remote control unit must; Note for GA3700T Series Only:; OPTIONAL BLOWER OPERATION
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 20 Figure 43 - Correct Pilot Flame Pattern Figure 44 - Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame p...
Page 21 - CLEANING AND MAINTENANCE; BURNER PRIMARY AIR HOLES; WARNING: If yellow tipping occurs, your fireplace; BURNER FLAME PATTERN; If burner flame pattern is incorrect, as shown in Figure 46; Figure 45 - Correct Burner Flame Pattern; Yellow Tipping; Figure 46 - Incorrect Burner Flame Pattern; WARNING: Turn off fireplace and let cool before; Blow air through the ports/slots and holes in the burner.; Figure 47 - Injector Holder On Outlet Burner Tube
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 21 21 INSPECTING BURNERS Burner Primary Air Holes Main Burner Burner Flame Pattern CLEANING AND MAINTENANCE Cleaning Burner Injec...
Page 22 - Figure 48 - Pilot Inlet Air Hole; SPECIFICATIONS; WIRING DIAGRAM; Note
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 22 LOGS • If you remove logs for cleaning, refer to Installing Logs, pages 15 and 16, to properly replace logs. • Replace log(s) ...
Page 23 - TROUBLESHOOTING; WARNING: Turn off and let; POSSIBLE CAUSE
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 23 23 TROUBLESHOOTING TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and let...
Page 24 - OBSERVED PROBLEM
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 24 TROUBLESHOOTING TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of on...
Page 25 - IMPORTANT; REMEDY
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 25 25 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touc...
Page 26 - ILLUSTRATED PARTS BREAKDOWN
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 26 ILLUSTRATED PARTSBREAKDOWN VYGF33PRBVYGF33NRB (Shown) 17 27 4 O F F P IL OT O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25 15...
Page 27 - PARTS LIST; KEY
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 27 27 PARTS LIST This list contains replaceable parts used in your fireplace. Whenordering parts, follow the instructions listed ...
Page 29 - PART NUMBER
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 29 29 PARTS LIST FIREBOXVYGF33PRB & VYGF33NRB This list contains replaceable parts used in your fireplace. Whenordering parts...
Page 34 - ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 34 CORNER HEARTH BASE G3008F Series - Walnut FinishedG3009U Series - UnfinishedG3010F Series - Oak Finished For models VYGF33PRB ...
Page 35 - LAMINATE TRIM FOR HEARTH OR MANTEL; For all models. Included with accessory mantels.; Hearth Base Trim
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 35 35 ACCESSORIES LAMINATE TRIM FOR HEARTH OR MANTEL G3002J Series - Jade Marble Laminate Mantel TrimG3003J Series - Jade Marble ...
Page 36 - REPLACEMENT PARTS; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 36 REPLACEMENT PARTSTECHNICAL SERVICESERVICE HINTS REPLACEMENT PARTS Note: Use only original replacement parts. This will protect...
Page 37 - • ACCESSORIES; OWNER'S REGISTRATION FORM
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 37 37 • ACCESSORIES 1. Where will the product be used? ❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garag...
Page 38 - Postage
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 38 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 TM Postage Required
Page 39 - NOTES
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 39 39 NOTES _______________________________________________________________________________________________ _____________________...
Page 40 - NOT A UPC; LIMITED WARRANTY; For information about this warranty write:; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model
110148-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 40 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 www.desatech.com TM 110148-01Rev. A04/02 NOT A UPC LIMITED WAR...