Page 2 - SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; Get; Have heater serviced. Some people are more; WARNINGS; TABLE OF CONTENTS
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 SAFETY INFORMATION IMPORTANT: Read this owner’s manual carefully andcompletely before trying to assemble, operate, or ser-vice ...
Page 3 - ing and Maintenance,; Continued; PRODUCT IDENTIFICATION; Stove Body; Screen
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 1. This appliance is only for use with the type of gas indicated onthe rating plate. This appliance is not convertible for us...
Page 4 - National Fuel Gas Code,; Unusually Tight Construction; and; Confined and Unconfined Space; The National Fuel Gas Code ANSI Z223.1/NFPA 54; WARNING: This heater shall not be installed in a; LOCAL CODES; The National Fuel Gas Code; OPERATION; PRODUCT FEATURES
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 AIR FOR COMBUSTION ANDVENTILATION Today’s homes are built more energy efficient than ever. New materi-als, increased insulation...
Page 5 - Includes the room in which you will install heater plus any; WARNING: If the area in which the heater may be; Ventilation Air; AIR FOR COMBUSTION AND VENTILATION; Figure 2 - Ventilation Air from Inside Building; VENTILATION AIR; National Fuel
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 5 5 AIR FOR COMBUSTION ANDVENTILATION Continued DETERMINING FRESH-AIR FLOW FORHEATER LOCATION Determining if You Have a Confined ...
Page 6 - WARNING: A qualified service person must in-; INSTALLATION; Figure 3 - Ventilation Air from Outdoors; UNPACKING; Lift off corrugated box enclosing stove body crating.; Ventilation Air From Outdoors; National Fuel Gas Code, ANSI; Figure 4 - Unpacking Stove from Wooden Shipping Enclosure; STOVE BACK
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 6 NOTICE: This heater is intended for use as supple-mental heat. Use this heater along with your primaryheating system. Do not in...
Page 7 - CHECK GAS TYPE; Air for Combustion and Ventilation; Minimum Wall and Ceiling Clearances (see Figure 5)
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 7 7 s INSTALLATION Check Gas Type Clearances to Combustibles CAUTION: This heater creates warm air currents. These currents move ...
Page 8 - WARNING: A qualified service person must con-; Installation Items Needed; Accessories; Gas Log Heater; Back View; Install equipment shutoff valve in an accessible; External Regulator; WARNING: Never connect natural gas heater to
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 8 CONNECTING TO GAS SUPPLY WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes. Insta...
Page 9 - WARNING: Use pipe joint sealant that is resistant; Figure 8 - Gas Connection; Sediment Trap; CAUTION: Avoid damage to regulator. Hold gas; * Purchase the optional CSA design-certified equipment shutoff; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; CAUTION: Make sure external regulator has been; Figure 9 - Equipment Shutoff Valve; Closed
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 9 9 INSTALLATION Continued WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. INSTALLATION Connectin...
Page 10 - Figure 10 - Checking Gas Joints on Propane/LP Gas Unit; Control Valve Location; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Gas Meter; INSTALLING ROD AND SCREEN; Figure 12 - Assembling Rod and Screen; Rod
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 10 INSTALLATION Continued Figure 10 - Checking Gas Joints on Propane/LP Gas Unit Control Valve Location Propane/LPSupply Tank Equ...
Page 11 - FOR YOUR SAFETY; WARNING: If you do not follow these instructions; LIGHTING; OPERATING HEATER; Figure 14 - Installing One-Piece Stove Log Set; Burner; INSTALLING LOG SET; Make sure log does not cover any burner ports
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 11 11 OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or e...
Page 12 - INSPECTING BURNERS; Check pilot flame pattern and burner flame patterns often.; CAUTION: Do not try to adjust heating levels by; Shutting Off Heater; Shutting Off Burners Only (pilot stays lit); Manual
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 12 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 18 shows a correct pi...
Page 13 - WARNING: Turn off heater and let cool before; Removing the; Figure 20 - Injector Holder On Outlet Burner Tube; Figure 21 - Pilot Inlet Air Hole; Burner Tube; Blow air into the primary air holes on the injector holder.; WARNING: Failure to keep the primary air; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 13 13 CLEANING ANDMAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner...
Page 14 - WARNING: Turn off heater; POSSIBLE CAUSE; Cleaning and; OBSERVED PROBLEM; TROUBLESHOOTING
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 14 TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shouldservice and repai...
Page 16 - IMPORTANT; ing Gas Connections
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 16 WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do n...
Page 17 - SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; REPLACEMENT PARTS; PARTS UNDER WARRANTY; SPECIFICATIONS; EQUIPMENT SHUTOFF VALVE - GA5010
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 17 17 SERVICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit• burners will have delayed ignition• heater will not p...
Page 18 - ILLUSTRATED PARTS BREAKDOWN
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 18 14 16 3 4 15 5 11 6 12 7 10 15 8 9 1 17 2 18 18 18 13 ILLUSTRATED PARTSBREAKDOWN MODELS111485-01 AND 111485-02 ILLUSTRATED PAR...
Page 19 - see; PARTS LIST
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 19 19 PARTS LIST This list contains replaceable parts used in your stove. For replace-ment parts see Replacement Parts on page 17...
Page 22 - Tool & Equipment Company; PARTS CENTRALS
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 22 These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original re...
Page 23 - • Accessories; OWNER'S REGISTRATION FORM
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 23 23 • Accessories 1. Where will the product be used? ❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garag...
Page 24 - Postage; T APE
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 24 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 Postage Required T APE TAPE
Page 25 - NOTES
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 25 25 NOTES _______________________________________________________________________________________________ _____________________...
Page 26 - LIMITED WARRANTY; For information about this warranty write:; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
111487-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 26 LIMITED WARRANTY VENT-FREE PROPANE/LP GAS OR NATURAL GAS LOG HEATERS AND CAST IRON STOVE CHASSIS DESA Heating Products warrant...