Desa FSBVBPC - Manual
Desa FSBVBPC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CAST IRON STOVE AND BURNER SYSTEM; WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:
- Page 3 – OWNER’S MANUAL; American National Standards Institute, Inc.; LOCAL CODES; OPERATION
- Page 4 – Figure 3 - Minimum Clearances for Standard Installation; CAUTION: This stove creates
- Page 5 – STOVE BODY ASSEMBLY; Remove plastic bag from stove body.; Figure 7 - Laying Down Stove On Side; Figure 8 - Removing Pallet Wood From The Bottom of The Stove
- Page 6 – Figure 13 - Removing Front Assembly
- Page 7 – Gasket and connecting plate; Figure 16 - Installing Burner System into Cast Iron Stove Body
- Page 8 – WARNING: Never touch the; Figure 18 - Removing Rear Cover and Bottom Cover from Stove Body; Connect the white wire to the other ter-
- Page 9 – INSTALLING REAR COVER; WARNING: Failure to position; Figure 20 - Blower Wiring Layout; Figure 22 - Control Valve Terminals; INSTALLATION PRECAUTIONS
- Page 10 – WARNING: Installation should; Elbows; • This heater must be properly connected to; WARNING: This gas stove with; • Venting instruction contained in this
- Page 11 – Figure 26 - Venting Through a Side Wall; CHECKING VENT CAPACITY; Figure 27 - Test for Proper Venting; CHIMNEYS
- Page 12 – FLUE GAS SPILLAGE; Incorrect Vent Sizing
- Page 13 – CHECK GAS TYPE; Flue Gas Cooling
- Page 14 – WARNING: Never use an open; Installation Items Needed; Open lower door panel.; Figure 31 - Gas Connection
- Page 15 – Figure 33 - Equipment Shutoff Valve; Figure 34 - Checking Gas Joints for Propane/LP Gas Burner System; Figure 35 - Checking Gas Joints for Natural Gas Burner System
- Page 16 – WARNING: Installation must; The wire; WARNING: Do not connect; Figure 37 - Back View of Thermostat Base; Set the temperature adjustment to the
- Page 17 – CAUTION: Do not operate this; Figure 39 - Installing Battery in Receiver; Figure 40 - Installing Remote Receiver; Installing Remote Receiver
- Page 18 – WARNING: The glass door
- Page 19 – Figure 50 - Control Valve
- Page 20 – OPTIONAL REMOTE; Thermostat Control Operation; Lighting; GHRC Series Operation:
- Page 21 – • turn burner system off (see To Turn Off; Figure 53 - Pilot Assembly
- Page 22 – tem and let cool before cleaning.; GLASS DOOR; CAUTION: Wear gloves and; LOGS; ment Parts on page 26.; VENTING SYSTEM
- Page 23 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; nance, page 22) or replace pilot assembly; OBSERVED PROBLEM
- Page 24 – tenance, page 22) or replace burner orifice
- Page 26 – SERVICE HINTS; When Gas Pressure is Too Low; WIRING DIAGRAM; CAUTION: Label all wires prior; PARTS UNDER WARRANTY; Blower
- Page 27 – SPECIFICATIONS; FSBVBNC; ACCESSORIES
- Page 29 – PARTS LIST; PART NUMBER
- Page 31 – KEY; PARTS AVAILABLE — NOT SHOWN
- Page 32 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; INTERNATIONAL
CAST IRON STOVE AND B-VENT
(FREESTANDING FIREPLACE HEATER)
BURNER SYSTEM
OWNER’S OPERATION AND INSTALLATION MANUAL
NATURAL GAS BURNER SYSTEM MODEL FSBVBNC
PROPANE/LP GAS BURNER SYSTEM MODEL FSBVBPC
REMOTE READY
Save this manual for future reference.
IMPORTANT: This b-vent burner system must be installed into approved FMI cast iron stove
bodies, models (P)FC series ONLY. See page 3 of this manual.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— Installation and service must
be performed by a qualified in-
staller, service agency, or the gas
supplier.
This appliance may be installed in an aftermarket*, permanently located manufactured
(mobile) home, where not prohibited by state or local codes.
— This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
QUALIFIED INSTALLER: If you encounter problems during installation of this product, please
contact DESA International’s Technical Service Department at 1-800-337-2564.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com SAFETYINFORMATION 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used. 2. For propane/LP bur...
3 107600 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCTIDENTIFICATION Install and use stove and burner system withcare. Follow all local codes. In the absenceto local codes, use the current National FuelGas Code ANS Z223.1, also known asNFPA 54* (USA) or the current CAN/CGA-B149...
4 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com LOCATION AND SPACEREQUIREMENTS Determine the safest and most efficient loca-tion for your FMI B-vent freestanding stove.Make sure that rafters and wall studs are notin the way of the venting system. Choose alocat...