Page 2 - CAST IRON STOVE AND BURNER SYSTEM; WARNING: Any change to; WARNINGS; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:
2 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com SAFETYINFORMATION 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases unless a certified kitis used. 2. For propane/LP bur...
Page 3 - OWNER’S MANUAL; American National Standards Institute, Inc.; LOCAL CODES; OPERATION
3 107600 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCTIDENTIFICATION Install and use stove and burner system withcare. Follow all local codes. In the absenceto local codes, use the current National FuelGas Code ANS Z223.1, also known asNFPA 54* (USA) or the current CAN/CGA-B149...
Page 4 - Figure 3 - Minimum Clearances for Standard Installation; CAUTION: This stove creates
4 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com LOCATION AND SPACEREQUIREMENTS Determine the safest and most efficient loca-tion for your FMI B-vent freestanding stove.Make sure that rafters and wall studs are notin the way of the venting system. Choose alocat...
Page 5 - STOVE BODY ASSEMBLY; Remove plastic bag from stove body.; Figure 7 - Laying Down Stove On Side; Figure 8 - Removing Pallet Wood From The Bottom of The Stove
5 107600 OWNER’S MANUAL For more information, visit www.desatech.com STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stovebody crating. 2. Remove all screws fastening the woodframe enclosure. Spread wood frame openand lift away from plastic-bagged stovebody. The bottom pieces of pallet wood...
Page 6 - Figure 13 - Removing Front Assembly
6 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com CAST IRON STOVEAND B-VENTBURNER SYSTEMASSEMBLY Continued 9. Attach stove door by inserting step boltthrough door hinge pivot hole and intothreaded hole in stove body (see Fig-ure 9, page 5 and Figure 11). Use ana...
Page 7 - Gasket and connecting plate; Figure 16 - Installing Burner System into Cast Iron Stove Body
7 107600 OWNER’S MANUAL For more information, visit www.desatech.com CAST IRON STOVEAND B-VENTBURNER SYSTEMASSEMBLY Continued Continued INSTALLING B-VENTBURNER SYSTEM INTOSTOVE BODY 1. Carefully lift burner system and placeinto stove body from the rear of stove(see Figure 16). 2. Place gasket on top...
Page 8 - WARNING: Never touch the; Figure 18 - Removing Rear Cover and Bottom Cover from Stove Body; Connect the white wire to the other ter-
8 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com CAST IRON STOVEAND B-VENTBURNER SYSTEMASSEMBLY Continued WARNING: Never touch the blower wheel while in operation. NOTICE: If installing blower in anexisting stove burner system withgas connections, shut off gas ...
Page 9 - INSTALLING REAR COVER; WARNING: Failure to position; Figure 20 - Blower Wiring Layout; Figure 22 - Control Valve Terminals; INSTALLATION PRECAUTIONS
9 107600 OWNER’S MANUAL For more information, visit www.desatech.com INSTALLING REAR COVER 1. Place rear cover behind stove body.Rear cover will rest on the bottom ledgeof the stove body. 2. Place wi re harness from ON/ OFFswitch under the cast of stove body. 3. Using bolts provided, attach rear cov...
Page 10 - WARNING: Installation should; Elbows; • This heater must be properly connected to; WARNING: This gas stove with; • Venting instruction contained in this
10 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com Figure 23 - Typical B-Vent Installation WARNING: Installation should only be made by qualified per-sons who are familiar with thesafety procedures required forthe installation of the product,who are equipped wit...
Page 11 - Figure 26 - Venting Through a Side Wall; CHECKING VENT CAPACITY; Figure 27 - Test for Proper Venting; CHIMNEYS
11 107600 OWNER’S MANUAL For more information, visit www.desatech.com VENTINGINSTALLATION Continued Figure 25 - Vertical Venting ConfigurationThrough Chimney Figure 26 - Venting Through a Side Wall Continued CHECKING VENT CAPACITY Complete all gas piping, electrical, and ventconnections. After adjus...
Page 12 - FLUE GAS SPILLAGE; Incorrect Vent Sizing
12 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com HIGH ALTITUDEINSTALLATION Your FMI B-vent freestanding stove andburner system has been AGA tested andapproved for elevations from 0-2000 feet andCGA certified for elevations from 0-4500 feet. When installing thi...
Page 13 - CHECK GAS TYPE; Flue Gas Cooling
13 107600 OWNER’S MANUAL For more information, visit www.desatech.com STOVE AND B-VENTBURNER SYSTEMINSTALLATION INSTALLING GAS PIPING TOFIREPLACE LOCATION WARNING: A qualified in- staller or service person mustconnect burner system to gassupply. Follow all local codes. CAUTION: For propane/LP units,...
Page 14 - WARNING: Never use an open; Installation Items Needed; Open lower door panel.; Figure 31 - Gas Connection
14 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com Cap Pipe Nipple Tee Joint Pressure Testing Gas SupplyPiping System Test Pressures In Excess Of 1/2 PSIG(3.5 kPa) 1. Disconnect appliance with its appliancemain gas valve (control valve) ande q u i p m e n t s h ...
Page 15 - Figure 33 - Equipment Shutoff Valve; Figure 34 - Checking Gas Joints for Propane/LP Gas Burner System; Figure 35 - Checking Gas Joints for Natural Gas Burner System
15 107600 OWNER’S MANUAL For more information, visit www.desatech.com STOVE AND B-VENTBURNER SYSTEMINSTALLATION Continued Continued 4. Check all joints of gas supply pipingsystem. Apply commercial leak test so-lution to all gas joints. Bubbles formingshow a leak. Correct all leaks at once. 5. Reconn...
Page 16 - WARNING: Installation must; The wire; WARNING: Do not connect; Figure 37 - Back View of Thermostat Base; Set the temperature adjustment to the
16 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com INSTALLING OPTIONAL WALLMOUNTED THERMOSTAT -GWMT1, GWMS2 WARNING: Installation must be done by a qualified installerfamiliar with low voltage wiringprocedures. WARNING: Do not connect this thermostat to any elec...
Page 17 - CAUTION: Do not operate this; Figure 39 - Installing Battery in Receiver; Figure 40 - Installing Remote Receiver; Installing Remote Receiver
17 107600 OWNER’S MANUAL For more information, visit www.desatech.com REMOVING/REPLACINGGLASS DOOR CAUTION: Do not operate this burner system with a brokenglass door panel or without theglass door panel securely inplace. For replacement part in-f o r m a t i o n s e e R e p l a c e m e n t Parts, pa...
Page 18 - WARNING: The glass door
18 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com It is very important to install these logsexactly as instructed. Do not modify logs.Only use logs supplied with freestandingstove with burner system. 1. Remove glass door. See Removing/Re-placing Glass Door, pag...
Page 19 - Figure 50 - Control Valve
19 107600 OWNER’S MANUAL For more information, visit www.desatech.com TO TURN OFF GAS TO APPLIANCE 1. Set selector switch, located on sideof rear cover, in the “OFF” position. 2a. Open lower door panel. 2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF posi-tion to prevent drain...
Page 20 - OPTIONAL REMOTE; Thermostat Control Operation; Lighting; GHRC Series Operation:
20 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com 1. After lighting, let pilot flame burn forabout one minute. Turn control knobon the control valve to ON position.Turn flame adjustment knob any-where between HI and LO. Slide theselector switch to the REMOTE po...
Page 21 - • turn burner system off (see To Turn Off; Figure 53 - Pilot Assembly
21 107600 OWNER’S MANUAL For more information, visit www.desatech.com INSPECTINGBURNERS Check pilot flame pattern and burner flamepatterns often. PILOT ASSEMBLY The pilot assembly is factory preset for theproper flame height. Alterations may haveoccurred during shipping and handling. Calla qualified...
Page 22 - tem and let cool before cleaning.; GLASS DOOR; CAUTION: Wear gloves and; LOGS; ment Parts on page 26.; VENTING SYSTEM
22 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com CLEANING ANDMAINTENANCE WARNING: Turn off burner sys- tem and let cool before cleaning. CAUTION: You must keep con- trol areas, burners, and circulat-ing air passageways of stove andburner system clean. Inspectt...
Page 23 - TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; nance, page 22) or replace pilot assembly; OBSERVED PROBLEM
23 107600 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Onlya qualified service person shouldservice and repair heater. CAUTION: Never use a wire, n...
Page 24 - tenance, page 22) or replace burner orifice
24 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise whenburner is...
Page 26 - SERVICE HINTS; When Gas Pressure is Too Low; WIRING DIAGRAM; CAUTION: Label all wires prior; PARTS UNDER WARRANTY; Blower
26 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com SERVICE HINTS When Gas Pressure is Too Low • pilot will not stay lit • burners will have delayed ignition • burner system will not produce specified heat • propane/LP gas supply might be low (propane/LP units on...
Page 27 - SPECIFICATIONS; FSBVBNC; ACCESSORIES
27 107600 OWNER’S MANUAL For more information, visit www.desatech.com SPECIFICATIONS FSBVBNC FSBVBPC 21,000-30,000 Btu/h 20,000-28,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Ther...
Page 29 - PARTS LIST; PART NUMBER
29 107600 OWNER’S MANUAL For more information, visit www.desatech.com PARTS LIST FSBVBNCFSBVBPC This list contains replaceable parts used in your burner system. When ordering parts, follow theinstructions listed under Replacement Parts on page 26 of this manual. KEYNO. PART NUMBER DESCRIPTION QTY. 1...
Page 31 - KEY; PARTS AVAILABLE — NOT SHOWN
31 107600 OWNER’S MANUAL For more information, visit www.desatech.com PARTS LIST FMI STOVE(P)FC SERIES This list contains replaceable parts used in your stove. When ordering parts, follow the instructionslisted under Replacement Parts on page 26 of this manual. * Included In Hardware Kit KEY PART NO...
Page 32 - KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; INTERNATIONAL
LIMITED WARRANTY B-VENT BURNER SYSTEM AND FMI STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of firstpurchase, provided that the product has been properly installed, operated and maintained in accordance wit...