Table of Contents:
- Page 2 – CONTENTS; SECTION; SAFETY; Safety Information continued on page 3; WARNINGS; Carbon monoxide poisoning may lead to death!; Early signs of carbon monoxide poisoning
- Page 3 – Continued
- Page 4 – American National Standards Institute, Inc.
- Page 5 – WARNING; Confined and Unconfined Spaces; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; ous water vapor retarder with a rating of one perm (6x10
- Page 6 – Determining if You Have a Confined or Unconfined Space
- Page 7 – Figure 2 - Ventilation Air from Inside Building; AIR FOR; VENTILATION AIR; Ventilation Air From Inside Building
- Page 8 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors
- Page 9 – NOTICE; CHECK GAS TYPE; • external regulator (supplied by; LOCATING HEATER; This heater is designed to be mounted on a wall.; Never install the heater; If you install the heater in a home garage; CAUTION
- Page 10 – JOINING WALL; INSTALLING HEATER TO WALL; Marking Screw Locations; Determine where you will locate heater.; For convenience and efficiency, install heater; THERMOSTAT SENSING BULB
- Page 11 – Installing Two Mounting Screws; package is provided with heater.; Attaching to wall stud method; INSTALLING TO; Figure 7 - Popping Open Anchor Wings For Thin Walls
- Page 12 – Installing Bottom Mounting Screw; Figure 11 - Installing Bottom Mounting Screw; Placing Heater On Mounting Screws; are in small portion of slots.; Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater; Removing Front Panel Of Heater; Figure 10 - Removing Front Panel Of Heater
- Page 13 – Figure 12 - External Regulator With Vent Pointing Down
- Page 14 – Figure 13 - Gas Connection; PRESSURE TESTING GAS SUPPLY PIPING SYSTEM; Test Pressures In Excess Of 1/2 PSIG; Connecting to Gas Sup-
- Page 15 – water to gas joints. Bubbles forming show a leak.; Test Pressures Equal To or Less Than 1/2 PSIG; PRESSURE TESTING HEATER GAS CONNECTIONS; internal joints for leaks.; CHECKING; Figure 14 - Manual Shutoff Valve; Figure 15 - Checking Gas Joints
- Page 16 – Figure 16 - Control Knob In The OFF Position; LIGHTING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING
- Page 18 – TO TURN OFF GAS TO APPLIANCE; OPERATING; Shutting Off Heater; to the OFF position.; to the PILOT position.; THERMOSTAT CONTROL OPERATION
- Page 19 – Check pilot flame pattern and burner flame pattern often.; PILOT FLAME PATTERN; Figure 18 - Correct Pilot Flame Pattern; If pilot flame pattern is incorrect, as shown in Figure 19; Figure 19 - Incorrect Pilot Flame Pattern
- Page 20 – BURNER FLAME PATTERN; INSPECTING; Figure 20 - Correct Burner Flame Pattern; INCORRECT FLAME PATTERN; Figure 21 - Incorrect Burner Flame Pattern; If burner flame pattern is incorrect, as shown in Figure 21
- Page 21 – ODS/PILOT AND BURNER ORIFICE; Air Passageways; Turn off heater and let cool before cleaning.; SHOOTING; Note: All troubleshooting; REMEDY
- Page 25 – SPECIFICATIONS; When gas pressure is too low; SERVICE
- Page 26 – ILLUSTRATED PARTS BREAKDOWN
- Page 27 – PARTS LIST
- Page 28 – for parts replaced under warranty.; Parts Under Warranty; When contacting your dealer or DESA International, have ready:; Parts Not Under Warranty; When calling DESA International, have ready:; REPLACEMENT
- Page 30 – NOTES
- Page 32 – KEEP THIS WARRANTY; WARRANTY INFORMATION; LIMITED WARRANTY
VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
®
Model: CGP10T and CGP10TL
Save this manual for future reference.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is
permitted after the manufactured (mobile) home is sited)
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• I m m e d i a t e l y c a l l y o u r g a s s u p p l i e r f r o m a
neighbor’s phone. Follow the gas supplier’s in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Air for
Combustion and Ventilation sec-
tion in this manual.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 103575 CONTENTS SECTION PAGE SAFETY INFORMATION Safety Information continued on page 3 WARNINGS IMPORTANT: Read this owner’s manual carefully and completely be-fore trying to assemble, operate, or service this heater. Improper use ofthis heater can cause serious injury or death from burns, fire, e...
3 103575 SAFETY INFORMATION Continued WARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP s...
4 103575 PRODUCT IDENTIFICATION PRODUCT FEATURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS).The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shutsoff the heater if there is not enough fresh air. Piezo Ignition System This h...