Desa CGP10RLA - Manual

Desa CGP10RLA

Desa CGP10RLA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – PROPANE/LP GAS HEATER; WARNING: Do not use any; WARNINGS; Carbon Monoxide Poisoning:; Early signs
  • Page 3 – OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.; SAFETY PILOT
  • Page 4 – Confined and Unconfined Space; WARNING: This heater shall; Unusually Tight Construction; kg
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
  • Page 6 – Figure 2 - Ventilation Air from Inside Building; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; VENTILATION AIR
  • Page 7 – INSTALLATION; CHECK GAS TYPE; LOCATING HEATER; Marking Screw Locations; Figure 5 - Mounting Screw Locations
  • Page 8 – Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching to Wall Stud Method; For attaching mounting screw to wall stud; Attaching to Wall Anchor Method; Do not hammer key! For; Figure 6 - Folding Anchor; Removing Front Panel of Heater; Mark screw location on wall.
  • Page 9 – CAUTION: Never connect heater; Figure 13 - Gas Connection; Hold pressure regulator with
  • Page 10 – FOR YOUR SAFETY; Figure 15 - Checking Gas Joints; WARNING: Never use an open; Correct all leaks at once.
  • Page 11 – WARNING: When running; CAUTION: Do not try to adjust; Control; Shutting Off Heater
  • Page 12 – Figure 19 - Correct Pilot Flame Pattern; Figure 20 - Incorrect Pilot Flame Pattern; PILOT FLAME PATTERN; BURNER FLAME PATTERN; CAUTION: You must keep; Figure 22 - Incorrect Burner Flame Pattern; CABINET; Air Passageways; Figure 23 - Pilot Inlet Air Hole
  • Page 13 – TROUBLESHOOTING; OBSERVED PROBLEM; WARNING: Turn off heater; All troubleshooting items are listed in
  • Page 14 – REMEDY
  • Page 15 – IMPORTANT
  • Page 16 – PARTS UNDER WARRANTY; When Gas Pressure Is Too Low; SERVICE HINTS
  • Page 17 – PARTS CENTRALS
  • Page 19 – PARTS LIST; KEY
  • Page 20 – KEEP THIS WARRANTY; WARRANTY INFORMATION; INTERNATIONAL; LIMITED WARRANTY; NOT A UPC
Loading the manual

INFRARED VENT-FREE PROPANE/LP GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

CGP10RLA

Save this manual for future reference.

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or the
gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to

Air For Combustion

and Ventilation section on page
4 of this manual.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
q u a l i f i e d i n s t a l l e r , s e r v i c e
agency, or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PROPANE/LP GAS HEATER; WARNING: Do not use any; WARNINGS; Carbon Monoxide Poisoning:; Early signs

2 104275 PROPANE/LP GAS HEATER Do not place clothing or otherflammable material on or nearthe appliance. Never place anyobjects on the heater. Surface of heater becomes veryhot when running heater. Keepchildren and adults away fromhot surface to avoid burns orclothing ignition. Heater will re-main h...

Page 3 - OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.; SAFETY PILOT

3 104275 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of the National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 1...

Page 4 - Confined and Unconfined Space; WARNING: This heater shall; Unusually Tight Construction; kg

4 104275 PROPANE/LP GAS HEATER AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the cold air ou...

Other Desa Models