Page 2 - PROPANE/LP GAS HEATER; WARNING: Do not use any; WARNINGS; Carbon Monoxide Poisoning:; Early signs
2 104275 PROPANE/LP GAS HEATER Do not place clothing or otherflammable material on or nearthe appliance. Never place anyobjects on the heater. Surface of heater becomes veryhot when running heater. Keepchildren and adults away fromhot surface to avoid burns orclothing ignition. Heater will re-main h...
Page 3 - OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.; SAFETY PILOT
3 104275 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of the National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 1...
Page 4 - Confined and Unconfined Space; WARNING: This heater shall; Unusually Tight Construction; kg
4 104275 PROPANE/LP GAS HEATER AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the cold air ou...
Page 5 - DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
5 104275 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless p...
Page 6 - Figure 2 - Ventilation Air from Inside Building; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; VENTILATION AIR
6 104275 PROPANE/LP GAS HEATER Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 Figure 2 - Ventilation Air from Inside Building AIR FORCOMBUSTION ANDVENTILATION Continued Figure 3 - Ventilat...
Page 7 - INSTALLATION; CHECK GAS TYPE; LOCATING HEATER; Marking Screw Locations; Figure 5 - Mounting Screw Locations
7 104275 OWNER’S MANUAL INSTALLATION CHECK GAS TYPE Use only propane/LP. If your gas supply isnot propane/LP, do not install heater. Calldealer where you bought heater for propertype heater. INSTALLATION ITEMS Before installing heater, make sure you havethe items listed below. • piping (check local ...
Page 8 - Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching to Wall Stud Method; For attaching mounting screw to wall stud; Attaching to Wall Anchor Method; Do not hammer key! For; Figure 6 - Folding Anchor; Removing Front Panel of Heater; Mark screw location on wall.
8 104275 PROPANE/LP GAS HEATER INSTALLATION Continued Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack-age is provided with heater. Attaching to Wall Stud Method For attaching mounting screw to wall stud 1. Drill hole at marked location...
Page 9 - CAUTION: Never connect heater; Figure 13 - Gas Connection; Hold pressure regulator with
9 104275 OWNER’S MANUAL CONNECTING TO GASSUPPLY Figure 12 - External Regulator With VentPointing Down Propane/LPSupply Tank VentPointingDown ExternalRegulator WARNING: A qualified ser- vice person must connect heaterto gas supply. Follow all localcodes. INSTALLATION Continued The installer must supp...
Page 10 - FOR YOUR SAFETY; Figure 15 - Checking Gas Joints; WARNING: Never use an open; Correct all leaks at once.
10 104275 PROPANE/LP GAS HEATER O POSI PO OPERATINGHEATER FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting thepilot, follow these instructions exactly. B. B E F O R E L I G H T I N G s m e l l a l l around the appliance area for gas. Bes...
Page 11 - WARNING: When running; CAUTION: Do not try to adjust; Control; Shutting Off Heater
11 104275 OWNER’S MANUAL OFF PILOT IGNITOR LOW HIGH TO SELECT HEATING LEVEL 1. Slightly press in control knob andturn counterclockwise to the LOW or HIGH positions. IMPORTANT: Release downward pressure while turning control knob.Control knob will lock at the desiredposition. OPERATINGHEATER Continue...
Page 12 - Figure 19 - Correct Pilot Flame Pattern; Figure 20 - Incorrect Pilot Flame Pattern; PILOT FLAME PATTERN; BURNER FLAME PATTERN; CAUTION: You must keep; Figure 22 - Incorrect Burner Flame Pattern; CABINET; Air Passageways; Figure 23 - Pilot Inlet Air Hole
12 104275 PROPANE/LP GAS HEATER GRH/OV 008 BAD PILOT/LP INSPECTINGBURNER GRH/OV GOOD PILOT/LP Thermocouple Figure 19 - Correct Pilot Flame Pattern Thermocouple Figure 20 - Incorrect Pilot Flame Pattern Pilot Burner Check pilot flame pattern and burner flamepattern often. PILOT FLAME PATTERN Figure 1...
Page 13 - TROUBLESHOOTING; OBSERVED PROBLEM; WARNING: Turn off heater; All troubleshooting items are listed in
13 104275 OWNER’S MANUAL Continued TROUBLESHOOTING CAUTION: Never use a wire, needle, or similar object to cleanODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM When ignitor button is pressed and controlknob is pressed in and turned to the PILOTposition, there is no spark at ODS/pilot Whe...
Page 14 - REMEDY
14 104275 PROPANE/LP GAS HEATER TROUBLESHOOTING Continued REMEDY 1. Clean burner orifice(s) (see Cleaning and Maintenance, page 12) or replaceburner orifice(s) 2. Replace burner orifice(s)3. Contact local propane/LP gas company 1. Contact local propane/LP gas company2. Clean burner orifice(s) (see C...
Page 15 - IMPORTANT
15 104275 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s ...
Page 16 - PARTS UNDER WARRANTY; When Gas Pressure Is Too Low; SERVICE HINTS
16 104275 PROPANE/LP GAS HEATER REPLACEMENTPARTS Note: Use only original replacement parts. This will protect your warranty coverage forparts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealer from whom youpurchased this product. If they cannot sup-ply original replacement part(...
Page 17 - PARTS CENTRALS
17 104275 OWNER’S MANUAL PARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacementparts and accessories. Baltimore Electric 1348 Dixwell AvenueHamden, CT 06514-03221-800-397-7553203-248-7553Parts Department ...
Page 19 - PARTS LIST; KEY
19 104275 OWNER’S MANUAL PARTS LIST CGP10RLA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listedunder Replacement Parts on page 16 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-07 Front Pane...
Page 20 - KEEP THIS WARRANTY; WARRANTY INFORMATION; INTERNATIONAL; LIMITED WARRANTY; NOT A UPC
KEEP THIS WARRANTY WARRANTY INFORMATION 104275-01Rev. C02/00 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 www.desatech.com INTERNATIONAL LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials an...