Desa CGB3930NR - Manual

Desa CGB3930NR

Desa CGB3930NR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – UVENTED NATURAL GAS LOG HEATER; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
  • Page 3 – OWNER’S MANUAL; Operation; Do not pick up; UNPACKING; American National Standards Institute, Inc.
  • Page 4 – Unusually Tight Contruction; Unusually Tight Construction; per
  • Page 5 – Determining if You Have a Confined or Unconfined Space; Continued
  • Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building
  • Page 7 – INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace; LOG SIZING REQUIREMENTS
  • Page 8 – If Not Using Mantel; If using a mantel, go to If Using; If Using Mantel; If you cannot meet these; Requirements for
  • Page 9 – Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; Floor Clearances; A. If installing appliance on the floor level,; Figure 7 - Minimum Mantel Clearances When Using Hood
  • Page 10 – WARNING: If installing in a; Fitting; Installation Items Needed; CAUTION: Do not remove the
  • Page 11 – CAUTION: Avoid damage to; WARNING: Never connect; Figure 12 - Gas Connection; Tee Joint; WARNING: Never use an open
  • Page 12 – Figure 13 - Manual Shutoff Valve; Open; Figure 14 - Checking Gas Joints; Gas Meter; Only use alkaline batteries.; Battery Cover; Correct all leaks at once.
  • Page 13 – WARNING: Failure to position; CAUTION: After installation
  • Page 15 – • If fireplace has glass doors,; FOR YOUR SAFETY; WARNING: Damper handle; Figure 26 - Control Knob and Ignitor Button Location; Control Knob
  • Page 16 – Remote Selector Switch in Remote Position; Lighting; Shutting Off Heater; Ignitor Electrode
  • Page 17 – Shows Temperature Setting; Figure 28 - Thermostat Hand-Held Remote Control Unit Selections; Figure 29 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; Thermocouple; WARNING: Turn off heater; • Use a vacuum cleaner or small, soft; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER
  • Page 18 – TROUBLESHOOTING; POSSIBLE CAUSE
  • Page 19 – OBSERVED PROBLEM; nance, page 17) or replace burner orifice
  • Page 20 – IMPORTANT
  • Page 21 – SPECIFICATIONS; When Gas Pressure Is Too Low; SERVICE HINTS
  • Page 23 – PARTS LIST; PART NUMBER
  • Page 25 – KEY
  • Page 26 – PARTS UNDER WARRANTY; PARTS CENTRAL
  • Page 27 – NOTES
  • Page 28 – For information about this warranty write:; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
Loading the manual

Save this manual for future reference.

WARNING: Improper installation, ad-
justment, alteration, service, or mainte-
nance can cause injury or property dam-
age. Refer to this manual for correct
installation and operational procedures.
For assistance or additional informa-
tion consult a qualified installer, ser-
vice agency, or the gas supplier.

WARNING: This appliance is for instal-
lation only in a solid-fuel burning ma-
sonry or UL127 factory-built fireplace,
or in an approved ventless firebox. It is
design certified for these installations
in accordance with ANSI Z21.11.2.
Exception: Do not install this appli-
ance in a factory-built fireplace that
includes instructions stating it has not
been tested or should not be used with
unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to

Air for Combustion and Ventilation section on page 4 of this manual.

®

PREMIUM AGED SPLIT OAK AND

YELLOW FLAME UNVENTED (VENT-FREE)

NATURAL GAS LOG HEATERS

CGD3924NR
CGB3924NR
CGB3930NR

24" and 30" Remote

Controlled Model

PIL

O T

O

F

F

O

N

LO

REMOTE

OFF

HI

OWNER’S OPERATION AND INSTALLATION MANUAL

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.

Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

Installation and service must be per-

formed by a qualified installer, service
agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not
prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.

Remote Control

Operation Requires

Two (2) 9-Volt Alkaline

Batteries Not Included

(Yellow Flame Model Shown)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - UVENTED NATURAL GAS LOG HEATER; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide

2 104306 UVENTED NATURAL GAS LOG HEATER CGD3924NR, CGB3924NR and CGB3930NR SAFETYINFORMATION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re-semble the flu, with headaches, dizziness,or nausea. If you have these signs, the heatermay not be working properly. Get fresh airat onc...

Page 3 - OWNER’S MANUAL; Operation; Do not pick up; UNPACKING; American National Standards Institute, Inc.

3 104306 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Yellow Flame Vent-Free Gas Log Heater Shown (Logs May Vary by Model) Operation This heater is clean burning. It requires nooutside venting. There is no heat loss out avent or up a chimney. Heat is generated byrealistic dancing, yellow flames. ...

Page 4 - Unusually Tight Contruction; Unusually Tight Construction; per

4 104306 UVENTED NATURAL GAS LOG HEATER CGD3924NR, CGB3924NR and CGB3930NR AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk aro...

Other Desa Models