DeLonghi PACA100ECO - User Manual

DeLonghi PACA100ECO

DeLonghi PACA100ECO Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
Page: / 19

Table of Contents:

  • Page 2 – ELECTRICAL CONNECTIONS; WHAT IS THE WATER-AIR PINGUINO
  • Page 3 – DESCRIPTION
  • Page 4 – PREPARING FOR USE; Air-conditioning without installation
  • Page 5 – Air-conditioning with installation; • Fit the flange accessory (S) provided in the; Keep the air hose as short and free of cur-
  • Page 6 – The appliance is fitted with a resin lime-; CF; ” is displayed when the limescale fil-; Setting water hardness; To set water hardness, proceed as follows:; Filling the tank
  • Page 7 – Replacing the limescale filter
  • Page 8 – button; Turning the appliance on; Resin filter
  • Page 11 – USING THE REMOTE CONTROL; Inserting or replacing the batteries; USING THE REMOTE CONTROL UNIT
  • Page 12 – When the BOOST function is active, the; Selecting the temperature scale
  • Page 13 – PROGRAMMING THE TIMER; Programming start up
  • Page 14 – Error messages are displayed on the appliance display.; Low Temperature; Probe Failure
  • Page 16 – CLEANING; Cleaning the cabinet
  • Page 17 – Emptying the tank
  • Page 18 – TECHNICAL CHARACTERISTICS:; Limit conditions; GUARANTEE
  • Page 19 – TROUBLESHOOTING
Loading the manual

21

• Use this appliance only as described in this

instruction manual.

As with all electrical equipment, whilst the

instructions aim to cover as many eventuali-

ties as possible, caution and common sense

should be applied when operating and instal-

ling this appliance.

• This appliance is designed for home air con-

ditioning and must not be used for other pur-

poses.

• It is dangerous to modify or alter the charac-

teristics of the appliance in any way.

• The appliance must be installed in conformi-

ty with national legislation regulating electri-

cal equipment and installations.

• If the appliance requires repair, contact a

Service Centre authorised by the manufactu-

rer only.

Repairs carried out by unauthorised person-

nel may be dangerous.

• This appliance must be used exclusively by

adults.

The appliance is not intended for use by per-

sons (including children) with reduced phy-

sical, sensory or mental capabilities, or lack

of experience and knowledge, unless they

have been given supervision or instruction

concerning use of the appliance by a person

responsible for their safety.

Children should be supervised to ensure that

they do not play with the appliance.

• The appliance must be connected to an effi-

cient earth system.

Have your electrical circuit checked by a qua-

lified electrician.

• Do not use extension cables.

• Before cleaning or maintenance, always un-

plug the appliance from the mains socket.

• Never unplug the appliance by pulling on the

power cable.

• Do not install the appliance in rooms contai-

ning gas, oil or sulphur. Do not install near

sources of heat. .

• Keep the appliance at least 50 cm away from

flammable substances (alcohol etc) or pres-

surised containers (eg aerosol cans).

• Do not rest heavy or hot objects on top of the

appliance.

• Clean the air filter at least once a week.

• Avoid using heating appliances near the air

conditioner.

• Always transport the appliance upright or re-

sting on one side.

Before moving the appliance, empty the in-

ternal circuit completely of water.

After moving the appliance, wait at least 1

hour before starting it

• When putting the appliance away, do not co-

ver with plastic bags.

• The materials used for packaging can be re-

cycled.

You are therefore recommended to dispose

of them in special differentiated waste col-

lection containers.

• At the end of its working life, consign the ap-

pliance to a specialist collection centre.

• If the power cable is damaged, it must be re-

placed by the manufacturer or an authorised

technical service centre in order to avoid all

risk.

Check the type of refrigerant gas used by your

appliance on the rating plate.

Specific warnings for appliances with

R410A refrigerant gas

R410A refrigerant gas conforms to EC regula-

tions on the environment.

Avoid perforating the refrigerant circuit of the

appliance.

ENVIRONMENTAL INFORMATION:

This unit contains fluorinated greenhouse gases

covered by the Kyoto Protocol.

Maintenance and disposal must be carried out by

qualified personnel only (R410A, GWP=1975).

Specific warnings for appliances with

R290 refrigerant gas

• Read the warnings carefully.

• When defrosting or cleaning, use only

the implements recommended by the

manufacturer.

• The appliance must be placed in a room

without continuously operating sources

of ignition (for example: open flames, an

operating gas appliance or an operating

electric heater).

• Do not pierce or burn.

I M P O R T A N T S A F E G U A R D S

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ELECTRICAL CONNECTIONS; WHAT IS THE WATER-AIR PINGUINO

22 • Refrigerant gas may be odourless. • The appliance must be installed, used and stored in a room with a surface area greater than 15 m². • This appliance contains about 300 g of R290 refrigerant gas. • R290 refrigerant gas complies with European environmental directives. Do not perforate any of t...

Page 3 - DESCRIPTION

23 DESCRIPTION A Air outlet grilleB Control panel with advanced LCD displayC HandleD Grille E CastorsF Air intake grille with dust filterG Condensate drain connectorH Power cableI Pull out tankJ Tank doorK Air exhaust hose L Remote controlM Air exhaust hose housingN Window outletO Silver ion filter ...

Page 4 - PREPARING FOR USE; Air-conditioning without installation

24 You can also use the “adjustable bar” accessory (T).• Fit the window outlet in the housing in the bar (fig. 4) • Position the bar on the window sill and adjust until it fits in the guides of the blind (the length can be blocked with the pin pro-vided), then lower the blind (fig. 5). • Fit the air...

Other DeLonghi Air Conditioners Models