  • Page 2 – Dayton Operating Instructions and Parts Manual; Product Identification
  • Page 3 – General Safety Information; IMPORTANT
  • Page 4 – THEORY OF OPERATION; Figure 5 - Cross Section Operational View; THE AIR SYSTEM
  • Page 5 – Safety Information; Operation
  • Page 6 – To Start Heater; Figure 6 - Flame-Out Control Reset Button; NOTE
  • Page 7 – Maintenance; UPPER SHELL REMOVAL; Figure 9 - Fan Blades and Air Deflectors; SPARK PLUG; Figure 11 - Spark Plug Gap; FUEL FILTERS
  • Page 8 – PUMP; Figure 16 - Turning Fan with Hand; Figure 14 - Fuel Pump Filter and Canister
  • Page 9 – Figure 19 - Replacing Nozzle; NOZZLE; Figure 18 - Fuel Lines at Pump and; FUEL LINES
  • Page 10 – MAINTENANCE KITS; Figure 20 - Adjusting Pump Pressure; Figure 21 - Adjusting Pump Pressure
  • Page 11 – Preventative Maintenance Schedule; How Often
  • Page 12 – Wiring Diagram; Figure 22 - Wiring Diagram
  • Page 13 – Troubleshooting Chart; Corrective Action
  • Page 17 – Repair Parts List
  • Page 18 – Figure 26 - Accessory - High Pressure Fuel Gauge
  • Page 19 – Burner Head Assembly - Figure 25; Description; Accessory - Figure 26
  • Page 20 – Figure 27 - Repair Parts Illustration for Model 3E358B
  • Page 22 – Figure 28 - Repair Parts Illustration for Model 3E359B
  • Page 24 – LIMITED WARRANTY; Portable Oil-Fired heaters, Models covered in this manual, are; NOT A UPC
Loading the manual

Operating Instructions & Parts Manual

Dayton Portable
Oil-Fired Heaters

®

Form 5S2514

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

3E358B and 3E359B

Version B - For Reduction

G016.J

®

Figure 1 – Model 3E358B

Figure 2 – Model 3E359B

ARL LOGO

G 004

®

1. Remove all protective packing

applied to heater for shipment.

2. Remove heater from shipping

container.

3. Check heater for any shipping

damage. If heater is damaged,
promptly inform dealer where you
bought heater.

Unpacking

Description

Dayton Models 3E358B and 3E359B are 350,000 Btu/Hr heaters and 600,000 Btu/
Hr heaters, respectively. These heaters use only Kerosene or No. 1 fuel oil for
combustion and electricity to run the motor. They are primarily intended for well
ventilated indoor or outdoor temporary heating of buildings under construction,
alteration, or repair (Read

General Safety Information

section carefully). They

may be used in agricultural, industrial, and commercial environments.

Products

of combustion are vented into the area being heated.

Printed in U.S.A.
03430
0602/094/VCPVP

General Specifications

Model 3E358B

Model 3E359B

Output Rating .........................................

350,000 Btu/Hr

600,000 Btu/Hr

Amperage at 120V 60 Hz .......................

7.1

11.0

Fuel ..........................................................

Kerosene or No. 1 fuel

Kerosene or No. 1 fuel

Fuel Tank Capacity ..................................

30.0 U.S. Gallons

36.0 U.S. Gallons

Fuel Consumption ..................................

2.5 U.S. Gallons/Hr

4.0 U.S. Gallons/Hr

Motor .......................................................

1725 RPM

1725 RPM

Hot Air Output (CFM) .............................

1,350

3,300

Fuel Pump Pressure ................................

100 psi

110 psi

Heater Weight with Fuel .......................

390 Lb

550 Lb

Heater Weight without Fuel ..................

180 Lb

285 Lb

Spark Plug Gap .......................................

.075 inches

.075 inches

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Dayton Operating Instructions and Parts Manual; Product Identification

Dayton Operating Instructions and Parts Manual 2 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B Upper Shell Fuel Cap Thermostat Fuel Tank Power Cord Lower Shell Motor and PumpAssembly Hot Air Outlet Lower Shell Fuel Cap Thermostat Upper Shell Fuel Tank Power Cord Flame-Out ControlReset Button ...

Page 3 - General Safety Information; IMPORTANT

Dayton Operating Instructions and Parts Manual 3 ® Models 3E358B and 3E359B General Safety Information Make certain you read and understandall warnings. Keep these instructions forreference. They are your guide to safeand proper operation of this heater. Safety information appears throughoutthese in...

Page 4 - THEORY OF OPERATION; Figure 5 - Cross Section Operational View; THE AIR SYSTEM

Dayton Operating Instructions and Parts Manual 4 Dayton PortableOil-Fired Heaters ® 3E358B and 3E359B General Safety Information (Continued) THEORY OF OPERATION THE FUEL SYSTEM The motor turns the fuel pump. Thefuel pump pulls fuel from the fueltank. The fuel pump pushes fuelthrough a filter and a s...

Other Dayton Models

All Dayton Other