Page 2 - Dayton Installation, Operation, Maintenance and Parts Manual; Dayton High Intensity Heaters; Limited Warranty
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 1.0 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 - Safety Symbols; Commercial / Industrial; This heater is; NOT; approved for use in any residential; Not For Residential Use.; property damage, serious injury or death.
NOTICE CAUTION ! WARNING ! ! WARNING ! ! Caution indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. WARNING ! ! Improper installation, adjustment, alteration, service or maintenance can cause property damage, serious injury or death. Read and...
Page 4 - CAUTION; Clearance to Combustibles; Combustible Items Include:; WARNING
CAUTION ! Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 4 Clearance to Combustibles A critical safety factor to consider before installation is the clearances to combust...
Page 5 - Chart 1.1 - Clearance to Combustibles in Inches; Side; Back; Below; Mount Heater Level; FRONT VIEW; Gas Type; SIDE VIEW
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 5 Chart 1.1 - Clearance to Combustibles in Inches (see Figure 1.1) NOTE: If the heater is mounted beneath a non-combustible surface, a 24 in. mini...
Page 6 - Dayton
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 6 Public Garages: The installation of this heater in public garages must conform with the Standard for Parking Structures, ...
Page 7 - ayton
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H D ayton 7 FRONT/REAR 18˝ 22 1/2˝ DIM. “C” DIM. “A” SIDE VIEW 22 - 1/2˝ 19 -9/32˝ DIM. “B” MODEL BTU/H HEATER WIDTH DIM “A” HEATER DEPTH DIM “B” RA...
Page 8 - Safety Signs and Labels; Back Panel; SAMPLE; Rating Plate
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H Safety Signs and Labels It is important to provide warnings to alert individuals to potential hazards and safety actions. A...
Page 9 - Design; Fire sprinkler heads must be located at; to be used in
2.0 Installation WARNING ! ! CAUTION ! ® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 9 Read and understand, the installation, operating and maintenance instructions thoroughly before installin...
Page 10 - Key; Exhauster; Perimeter mounting; Figure 2.1 - Total Area Heating Sample Layout
Key Infra-red heater Exhauster Thermostat Air intake louver Perimeter mounting A B C Perimeter and center row mounting A B Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H ...
Page 11 - Average
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 11 B TU /H I n p u t Ty p e o f A re a (S u rr o u n d in g s) A p p ro x. A re a C ov ered A p p ro x. C ov er ag e (s q . f t. ) R ec o m m en d...
Page 12 - that can support the total force and weight of the heater.; Heater Mounting; The heater must be level
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H Improper suspension of the infra-red heater may result in collapse and being crushed. Always suspend from a permanent part ...
Page 13 - Figure 2.4 Heater Orientation; must
Dayton Steel C-clamp Chain hanging set Drip Leg/ Sediment Trap Optional 325-3 Regulator (Use when gas supply pressure exceeds 14: W.C.P.) Ball Valve / Inlet Tap Disconnect switch Stainless Steel Gas Connector, formed into smooth C-Shape ® Dayton Installation, Operation, Maintenance and Parts Manual ...
Page 14 - Ventilation; consumed must be; Figure 2.6 Hot Flue Discharge
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H Ventilation It is required that the upper levels of the space to be heated are properly ventilated to supply combustionair ...
Page 15 - Gas Supply; Chart 2.3 Manifold Pressure
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 15 Gas Supply WARNING ! ! Improperly connected gas lines may result in fire, explosion, poisonous fumes, toxic gases, asphyxiation or death. Conne...
Page 17 - Electric Shock Hazard.; Electrical; Thermostat; Proper grounding and polarity are essential; Avoid Equipment Failure.
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H Electric Shock Hazard. Field wiring to the heater must be connected and grounded in accordance with national, state, provincial, local codes and t...
Page 18 - Wiring Diagrams
(sold separately) Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 18 Wiring Diagrams Figure 2.9 - 24 V Schematic (5VD57 thru 5VD66) • Direct Spark Ignition • VA Draw: 12 •...
Page 19 - Lighting Instructions; Rotate the heater’s valve knob to the “ON”; Shutdown Instructions; Upon satisfactory completion of the electrical supply; Sequence of Operation; Upon a call for heat, voltage is
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H Do not atempt to ignite heater by hand. Failure to comply could result in personal injury, property damage, explosion, fire or death. 19 WARNING !...
Page 20 - Main Burner
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H WARNING ! ! 4.0 Maintenance Use protective glasses when cleaning the heater. It is recommended that the following become a ...
Page 21 - Symptom; Chart 4.1 Troubleshooting Guide
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 21 Symptom Possible Cause Corrective Action Burning of gas-air mixture inside plenum (flashback). • Heater mounted at incorrect angle. • Excessive...
Page 22 - Heater Assembly Components; Replacement burners are called “rayheads”
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 22 Heater Assembly Components NOTE: Replacement burners are called “rayheads” with rod inserts (part no. DR-RH and DR-ROD)....
Page 23 - Parts Listing; Chart 4.2 - Direct Spark Control Components; Gas type conversions require
® Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H Parts Listing 23 Chart 4.2 - Direct Spark Control Components Part No. Description Voltage VR8205A-2123 Combination gas valve, natural gas 25V VR42...
Page 24 - Additional Limited Warranty.
Dayton Installation, Operation, Maintenance and Parts Manual Dayton High Intensity Heaters ® 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 E NG L I S H 24 5.0 Limited Warranty Dayton One-Year Limited Warranty. Dayton Radiant High Intensity Heaters, Models 3E132, 3E460, 5VD61...