Dayton 2ZRP8 - Manual
Dayton 2ZRP8 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAVE THESE INSTRUCTIONS
- Page 3 – safety waRning when Refueling; electRical haZaRds
- Page 4 – Dayton; Installation; GROUNDING INSTRUCTIONS
- Page 5 – GENERAL RECOMMENDATIONS
- Page 6 – FUEL TYPE; Operation; RECOIL START
- Page 7 – ELECTRIC START; Maintenance; GENERATOR MAINTENANCE
- Page 8 – eVaPORatiVe eMissiOn cOMPOnents:; Maintenance Chart
- Page 10 – Storing Generator
- Page 11 – Troubleshooting Chart
- Page 12 – LIMITED WARRANTY
- Page 13 – Notes
- Page 15 – Repair Parts 2ZRP8
- Page 17 – Repair Parts 2ZRP9
- Page 19 – Repair Parts List for 2ZRP8 Generator
- Page 21 – Repair Parts List for 2ZRP9 Generator
- Page 23 – Repair Parts List for Fuel Tank
- Page 24 – rs
- Page 27 – INFORmAcIóN DE SEGuRIDAD; Descripción; Generator Dayton; manual de Instrucciones de Operación y Lista de Partes
- Page 30 – Instalación
- Page 32 – ANTES DE LA OPERAcIóN
- Page 33 – OPERAcIóN; ARRANquE DE RETROcESO
- Page 36 – ARRESTADOR DE cHISPA:; Almacenamiento de; Honda; NGK BPR6ES
- Page 37 – MANTENIMIENTO; Diario Cada Cada
- Page 38 – Tabla de Identificación de Problemas
- Page 40 – Servicio permanente – 24 horas al día al año
- Page 50 – ZR
- Page 52 – Notas
- Page 53 – CONSEILS DE SÉCuRItÉ ImPORtANtS; Description; manuel d’utilisation et de pièces détachées
- Page 54 – CONSERVER CES INStRuCtIONS
- Page 58 – HuILE Du mOtEuR; Avant opération; CARbuRANt
- Page 59 – HAutE ALtItuDE; FONCtIONNEmENt
- Page 61 – HAbItuELLEmENt, uN RÉGImE; causer des blessures.; VÉRIFICAtION Du NIVEAu D’HuILE:
- Page 62 – Moteur
- Page 63 – StOCKAGE Du GÉNÉRAtEuR
- Page 64 – ENTRETIEN; Chaque Toutes les Toutes les Toutes les
- Page 65 – tableau de dépannage
- Page 66 – GARANTIE LIMITÉE
- Page 68 – 4 heures par jour – 365 jours par an
- Page 69 – Liste des pièces détachées pour 2ZRP8
- Page 71 – Liste des pièces détachées pour 2ZRP9
- Page 73 – Liste des pièces détachées pour 2ZRP8 Alternateur
- Page 75 – Liste des pièces détachées pour 2ZRP9 alternateur
- Page 77 – Liste des pièces détachées pour Réservoir de Carburant
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S
Dayton
®
Generator
Operating Instructions & Parts Manual
2ZRP8, 2ZRP9
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S
Unpacking
When unpacking the unit, carefully
inspect for signs of obvious or concealed
freight damage. If damage does exist,
file a claim with the transportation com-
pany immediately. Be sure that all dam-
aged parts are replaced and that the
mechanical and electrical problems are
corrected prior to operation of the unit.
Tools Required: Philips #2 screwdriver
Specifications
Model ................................2ZRP8 ..........2ZRP9
Engine...............................Honda .........Honda
Watts (AC) Rated ................ 5000 ............6500
Watts (AC) Max. ................. 6000 ............7500
Rated Voltage (AC) .... 120V/240 .... 120V/240
Max. Amperage ........... 35.0/25.0 .....62.5/31.3
Cont. Amperage .......... 41.7/20.8 .....54.2/27.1
Frequency ............................60Hz ........... 60Hz
Fuel Tank Capacity ......... 7.3 gal. ........7.3 gal.
Run Time ......................... 8.0 hrs ......... 6.9 hrs
Dimensions (in) ............. 29L x 24.4W x 22.5H
General Safety Information
Read OPeRating instRuctiOns
Always become familiar with all the
instructions and warnings before
operating any generator
iMPORtant safety instRuctiOns
To reduce the risk
of injury, read this
operator’s manual completely before
using. When using this product, the
following basic precautions should
always be followed:
1. Read all the instructions before using
the product.
2. Do not allow children or untrained
persons to operate the generator.
3. Do not operate the generator when
fatigued or under the influence of
drugs or chemicals. Stay alert. Watch
what you are doing.
4. Follow the maintenance instructions
specified in this manual.
5. When starting the generator, using
recoil starter grip, be sure that
nothing is in a position to be hit by
the operator’s hand or arm.
6. Be sure the switch on electric power
tools is in the “OFF” position before
plugging them into the generator.
7. Keep the immediate area free of all
bystanders.
8. Be sure each person who operates
this generator is properly instructed
in its safe operation.
9. Do not operate the generator or any
electrical tool in any area where
water or similar materials constitute
an electrical hazard to the operator.
Do not operate on wet surfaces, in
rain or in snow.
10. Always be sure that the generator is
on secure footing so that it cannot
slide or shift around, endangering
workers.
11. Avoid contacting the hot exhaust
manifold, muffler or cylinder(s).
Keep clear of all rotating parts.
12. Unless the tool or appliance
is double insulated, it must be
grounded through a properly
grounded receptacle. (See
Preparing the Generator, Grounding
Instructions). Tools and appliances
Description
This Dayton generator was constructed with the highest level of precision and
accuracy. Each component has been rigorously tested by technicians to ensure the
quality, endurance and performance of this generator.
37-1023 091208
Form 5S6238
Printed in U.S.A.
06272
0908/433/VCPVP
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 E NG L I S H Dayton Operating Instructions and Parts Manual Dayton ® Generator 2ZRP8, 2ZRP9 which have 3 prong plugs must be plugged into extension cords and electrical receptacles with 3 holes. Before operating any electrical item, be sure it is in good repair. 13. Follow instructions in this man...
E NG L I S H Models 2ZRP8, 2ZRP9 Dayton Operating Instructions and Parts Manual Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up in your home, according to the manufacturer’s installation instructions. The carbon monoxide alarms should be certifi...
E NG L I S H Dayton Operating Instructions and Parts Manual Dayton ® Generator 2ZRP8, 2ZRP9 generator. Or, use a heavy duty, outdoor-rated extension cord that is rated (in watts or amps) at least equal to the sum of the connected appliance loads. Check that the entire cord is free of cuts or tears a...