Special Instructions for
DS1100 SH2347 and DS2200 SH2348
10 - 30 Vdc
Electrical Connections
The scanner cable is equipped with a 25-pin female D-sub connector for
connection with the power supply and input/output signals:
Figure 1 – 25-pin female D-sub connector
25-pin D-sub connector pinout
Pin Name
Function
9,13
VS
Power supply input voltage +
25
GND
Power supply input voltage -
1 *
CHASSIS
Chassis Ground
2, 21
TXAUX
TX RS232 Aux. Interface
3, 20
RXAUX
RX RS232 Aux. Interface
4
RTX485 -
RTX- RS485 Main Interface
5
RTX485 +
RTX+ RS485 Main Interface
7 SGND
Signal
Ground
8
OUT1 +
Output 1 +
11
OUT2 +
Output 2 +
18
EXT TRIG +
External trigger +
19
EXT TRIG -
External trigger -
10, 12, 22
I/O REF
Input/Output reference
17
IN1 -
Input 1 -
6, 14, 15, 16, 23, 24
N.C.
Not Connected
* Pins 1 and 25 are connected together internally.
851000292 (Rev. B)