Datalogic Scanning, Inc. 959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without p...
i PowerScan ® RF Scanner Datalogic Scanning, Inc. POWERSCAN ® END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product’s operation. ThisSoftware is being provided to you under license, subject to the terms and...
User’s Guide ii warranty period, Datalogic’s liability is limited to providing End User with one copy of corrections or responding to End User's problem reports accord-ing to Datalogic's standard assistance practices. Datalogic does not warrant that the product will meet End User's requirements or t...
iii PowerScan ® RF Scanner Standard Warranty Datalogic warrants to Customer that Datalogic's products will be free from defects in materials and workmanship for a period of three years from product ship-ment. In order to obtain service under this Warranty, Customer must notify Datalogic of the claim...
User’s Guide i MASTER CONTENTS Table of Contents ........................................................................... 1 Deutsches Inhaltsverzeichnis ....................................................... 29 Français Sommaire ......................................................................
User’s Guide 1 TABLE OF CONTENTS Unpack and Inspect Your Scanner ................................................................................1References ....................................................................................................................1Quick Start Instructions ....
User’s Guide 3 Unpack and Inspect Your Scanner After unpacking your new scanner, check the contents of the shipping carton to ensure all the items you ordered are included: • PowerScan ® RF handheld scanner • Battery Pack(s) • User ’s Guide (this manual) • Optional Accessories that you ordered. (The...
4 PowerScan ® RF Scanner Installing the Battery Orient the battery as shown in Figure 1, then push it into the scanner until it snaps in place. To remove the battery, push in on the release tabs on both sides of the battery’s base and pull it straight out of the scan-ner. Figure 1. Installing the Ba...
User’s Guide 5 Verifying Scanner Operation Once a charged battery has been installed in the scanner, scan the sam-ple bar codes in the back of this manual that correspond to the symbol-ogies your scanner is programmed to read. If unsure how to do this, see the section on How to Scan in this manual. ...
6 PowerScan ® RF Scanner Figure 2 . Connecting/Disconnecting the Interface (I/F) Cable 2. Consult your Host Terminal manual to determine the required communication parameters for the Host Terminal (e.g., baud rate, parity, etc.) and, if necessary, modify the programmed parameters to be compatible wi...
User’s Guide 7 The Base Station’s POWER LED should be illuminated when the unit is properly connected to power. Figure 3. Connecting Power to the Base Station 5. Apply power to the Host Terminal. 6. Verify communication with the Host Terminal by aiming the linked scanner at a sample bar code from th...
8 PowerScan ® RF Scanner The existing Base Station system configuration can be automatically downloaded to the scanner. This automatic download feature is config-urable and can be disabled. See the Systems Manual for more informa-tion about this feature. If downloading occurs, a slight delay with li...
User’s Guide 9 Verifying Scanner-to- Base Station Communications Point the linked scanner at a sample bar code from the back pages of this manual, and pull the trigger (see How to Scan for tips on scanning bar codes). Watch the TX/RX (transmit/receive) indicator LED on the Base Station and/or scanne...
10 PowerScan ® RF Scanner Using the PowerScan RF System This section covers the following topics: • Battery Charging and Maintenance • How to Scan • LED and Beeper Indications Battery Charging and Maintenance Seat the scanner in the Base Station as shown in Figure 4, ensuring that the battery fully ...
User’s Guide 11 Rapid flashing indicates that charging is taking place. Rapid charging occurs when the battery temperature is between 10°C (50°F) and 46°C (115°F), and/or voltage of the battery is between 2.0 and 3.2V. Charge time is less than 4.2 hours. Rapid charge ends with the battery at approxi...
12 PowerScan ® RF Scanner Disposing of Batteries There presently are no US, North America or World disposal require-ments for NiMH batteries, so when they won't hold a charge anymore, the batteries can be disposed of, preferably through a recycling center. Four Station Charger If you have a Four Sta...
User’s Guide 13 How to Scan Figure 6 illustrates some tips to help get the best scanning results: 1. The scanner must be pointed at a slight angle to the bar code. Do not hold the scanner perpendicular to the bar code. 2. The laser beam must cross the entire bar code. The scanner cannot correctly re...
14 PowerScan ® RF Scanner Depth of Field There are currently four different range models for the scanner. Depending upon the model type of your scanner, you’ll need to hold the unit at a given distance from the bar code to achieve optimum scan-ning results. The following diagrams provide depth of fi...
18 PowerScan ® RF Scanner LED and Beeper Indications The Base Station LED indicators and the scanner ’s LEDs and beeper are used to announce system status and perform other useful signals. The tables below list the default function of each of the various indica-tors. Table 1. Scanner GREEN LED Funct...
User’s Guide 19 Table 2. Scanner YELLOW LED Functions Table 3. Scanner BEEPER Functions LED INDICATION DURATION COMMENT Laser on indica-tion On Steady The yellow LED illuminates whenever the laser is on. SPEAKER INDICATION DURATION COMMENT Scanner Not Currently Linked Six beeps consisting of 20 ms o...
20 PowerScan ® RF Scanner Table 4 . Base Station LED Functions Transmission Error Beep High, then low, then high, then low. Indicates unsuccessful transmission to the host. Link Beep Low, then medium, then high. Indicates a scanner has been successfully linked to a base station. Unlink Beep High, th...
22 PowerScan ® RF Scanner Enhanced Scanning for Hard-to-Read Bar Codes Decoded scanners can be programmed to decode extremely poor qual-ity bar codes by activating advanced Quadralogic II™ Decoding. To select this feature, see the Programming Guide. Scanner programming can also be performed using yo...
User’s Guide 23 Laser Cautions The PowerScan RF bar code scanner is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J for Class II laser products (SR and LR) and Class IIIa (XLR) . Class II and IIIa products are not considered to be hazardous. The scanner contains ...
24 PowerScan ® RF Scanner Radio Frequency Interference This device complies with Part 15 of the FCC Rules. Operation is sub-ject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that m...
User’s Guide 25 Maintenance The scan window will require occasional cleaning to remove smudges, dust and other debris. To ensure optimal performance, clean the Scan Window using a soft cloth or lens tissue dampened with isopropyl alcohol (or equivalent). See Figure 12. The scanner body can also be c...
26 PowerScan ® RF Scanner Troubleshooting Troubleshoot your RF scanning system by performing the following checks: For the RF system, ensure that... • the battery is charged. See “Battery Charging and Mainte-nance” on page 10. • the battery is properly installed. See “Installing the Battery” on page...
User’s Guide 27 Sample Bar Codes Use these test bar codes to check the scanner ’s ability to read the vari-ous symbologies represented. Code 128 Code 39 Interleaved 2 of 5 Standard 2 of 5 Codabar Code 93 C o d e 1 2 8 . T e s t C O D E 3 9 . T E S T 0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 A $ 9 9 . ...
Benutzerhandbuch 29 DEUTSCHES INHALTSVERZEICHNIS Auspacken und Überprüfen Ihres Scanners ................................................................31Referenzen ..................................................................................................................31Anweisungen für de...
30 PowerSca n ® RF Handstrichcodeleser Datalogic Scanning Inc. 959 Terry StreetEugene, Oregon 97402Tel.: (541) 683-5700Fax: (541) 345-7140 Datalogic, das Datalogic-Logo, Quadralogic II und PowerScan sind eingetragene Warenzeichen der Datalogic Scanning, Inc. Alle anderen hier genannten Waren-zeichen...
Benutzerhandbuch 31 Auspacken und Überprüfen Ihres Scanners Nachdem Sie Ihren neuen Scanner ausgepackt haben, überprüfen Sie den Inhalt des Lieferkartons, ob auch alle von Ihnen bestellten Teile geliefert wurden: • PowerScan ® RF Handscanner • Batterie/n • Benutzerhandbuch (dieses Handbuch) • zusätz...
32 PowerSca n ® RF Handstrichcodeleser Einlegen der Batterie Richten Sie die Batterie wie in Abbildung 1 gezeigt aus und drücken Sie die Batterie dann so weit in den Scanner, bis sie einrastet. Die Batte-rie wird herausgenommen, indem Sie auf die Lösetasten an beiden Seiten des Batterieteils drücken...
34 PowerSca n ® RF Handstrichcodeleser Abbildung 2 Anschließen/Trennen des Schnittstellen-(I/F)Kabels 2. Lesen Sie im Hauptterminal-Handbuch die erforderlichen Kommunikationsparameter für das Hauptterminal nach (z.B. Baud-Rate, Parität, usw.) und ändern Sie falls erforderlich die programmierten Para...
Benutzerhandbuch 35 4. Schließen Sie das Stromkabel des AC-Adapters an die Basissta-tion an und stecken Sie den AC/DC-Adapter in die Wand-steckdose (siehe Abbildung 3). Die Strom-LED der Basisstation leuchtet, wenn die Einheit korrekt an das Stromnetz angeschlo-ssen ist. Abbildung 3: Die Basisstatio...
36 PowerSca n ® RF Handstrichcodeleser Die bestehende Systemkonfiguration der Basisstation kann automa-tisch auf den Scanner übertragen werden. Dieses Merkmal der automa-tischen Übertragung kann konfiguriert und abgestellt werden. Für weitere Informationen zu diesem Merkmal siehe Systemhandbuch. Bei...
Benutzerhandbuch 37 Prüfen der Verbindung Scanner-an- Basisstation Halten Sie den verbundenen Scanner auf einen Muster-Barcode der letzten Seiten dieses Handbuches und ziehen Sie den Auslöser (für Tipps zum Scannen von Barcodes siehe "Wie wird gescannt"). Während Sie den Barcode scannen, beo...
38 PowerSca n ® RF Handstrichcodeleser Anwenden des PowerScan RF-Systems Dieser Abschnitt behandelt die folgenden Punkte: • Batterieaufladung und Wartung • Wie wird gescannt • LED- und Signal-Anzeigen Batterieaufladung und Wartung Legen Sie den Scanner wie in Abbildung 4 gezeigt in die Basisstation ...
Benutzerhandbuch 39 Ein schnelles Blinken zeigt an, dass das Aufladen stattfindet. Ein schnelles Aufladen erfolgt, wenn die Batterietemperatur zwischen 10°C (50°F) und 46°C (115°F) liegt, und/oder die Batteriespannung zwischen 2,0 und 3,2 V liegt. Die Ladezeit beträgt weniger als 4,2 Stunden. Die sc...
40 PowerSca n ® RF Handstrichcodeleser Vier-Stationen- Ladegerät Wenn Sie über ein Vier-Stationen-Ladegerät verfügen, dann werden die Batterien zur Aufladung wie in Abbildung 5 gezeigt eingelegt. Eine 90%-ige Aufladung wird in nur zwei Stunden erzielt, wenn dieses zusätzliche Zubehör verwendet wird ...
Benutzerhandbuch 41 Wie wird gescannt Abbildung 6 zeigt einige Tipps, wie Sie die besten Ergebnisse beim Scannen erzielen können: 1. Der Scanner muss mit einem kleinen Winkel zum Barcode gehalten werden. 2. Der Laserstrahl muss den gesamten Barcode überqueren. Der Scanner kann nicht korrekt einlesen...
42 PowerSca n ® RF Handstrichcodeleser Feldtiefe Derzeit gibt es für den Scanner vier verschiedene Reichweitenmodelle. Abhängig vom Modelltyp Ihres Scanners, müssen Sie die Einheit mit einem bestimmten Abstand vom Barcode halten, um ein optimales Ergebnis beim Scannen zu erzielen. Die folgenden Diag...
46 PowerSca n ® RF Handstrichcodeleser LED- und Signal-Anzeigen Die LED-Anzeigen der Basisstation und die LEDs des Scanners sowie die Pieptöne geben den Systemstatus an und führen weitere nützliche Signale durch. Die folgende Tabelle listet die Standardvorgaben für jede der verschiedenen Anzeigen au...
48 PowerSca n ® RF Handstrichcodeleser Tabelle 4: LED-Funktionen der Basisstation Signal Bestäti-gung der Basiss-tation 100 ms an (kurz) 250 ms an (mittel) 500 ms an (lang) Zeigt an, dass eine erfolgreiche Barcode-Über-tragung zum Haupttermi-nal (konfigurierbar), ein erfolgreicher Kanalwechsel oder ...
50 PowerSca n ® RF Handstrichcodeleser Aktive Symboliken Die aktiven (aktivierten) Barcodesymboliken der werksseitigen Stan-dardvorgaben sind: • Code 39 (C39) • Code 128 (C128) • Überlappung 2 von 5 (I 2 von 5) Ihr Scanner sollte mit diesen werksseitigen Einstellungen der Stan-dardvorgaben vorprogra...
Benutzerhandbuch 51 Abbildung 11: Scanner-Etikettierung und Nomenklatur 1. Auslöser 4. Haltehaken 2. Scan-Fenster 5. Gelbe LED 3. Grüne LED 6. Batterie CAUTION—LA S ER RADIATION WHEN OPEN. AVOID EXPO S URE TO BEAM. COVERED BY ONE OR MORE OF THE FOLLOWING PATENT S : 4 , 3 8 7 , 2 9 7 • 4 , 4 0 9 , 4 ...
52 PowerSca n ® RF Handstrichcodeleser Warnhinweise für Laseranwendung Der PowerScan RF Barcodescanner ist in den USA zertifiziert und entspricht den Anforderungen von DHHS/CDRH 21 CFR Unterkapi-tel J für Laserprodukte der Klasse II (SR und LR) und Klasse IIIa (XLR). Produkte der Klasse II und IIIa ...
Benutzerhandbuch 53 Hochfrequente Störungen Dieses Gerät erfüllt Teil 15 der FCC-Bestimmungen. Der Betrieb unter-liegt den folgenden zwei Bedingungen: 1. Dieses Gerät verursacht keine schädlichen Störungen. 2. Dieses Gerät akzeptiert alle empfangenen Störungen, ein-schließlich Störungen, die einen n...
54 PowerSca n ® RF Handstrichcodeleser Wartung Das Scanfenster muss gelegentlich gereinigt werden, um Schmutz, Staub und andere Rückstände zu beseitigen. Für eine optimale Leis-tung reinigen Sie das Scanfenster mit einem weichen Tuch oder einem Linsentuch, das mit Isopropylalkohol (oder Ähnliches) a...
Benutzerhandbuch 55 Fehlersuche Sie führen die Fehlersuche für Ihr RF-Scanningsystem nach den fol-genden Checks durch: Für das RF-System vergewissern Sie sich, dass • die Batterie geladen ist. Siehe “Batterieaufladung und War-tung” auf Seite 38. • die Batterie korrekt eingelegt ist. Siehe “Einlegen ...
Benutzerhandbuch 57 Muster-Barcodes Verwenden Sie diese Test-Barcodes, um die Fähigkeit des Scanners zum Einlesen der verschiedenen Symboliken zu prüfen. Code 128 Code 39 Überlappend 2 von 5 Standard 2 von 5 Codabar Code 93 C o d e 1 2 8 . T e s t C O D E 3 9 . T E S T 0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 ...
Guide de L’utilisateur 59 FRANÇAIS SOMMAIRE Déballage et inspection de votre scanner ...................................................................61References ..................................................................................................................61Instructions Pour l...
60 Pow erScan ® RF Douchette Laser Datalogic Scanning SarlLES ULIS Cedex, FrancePh: [33].01.64.86.71.00Fax: [33].01.64 46.72.44 Datalogic, le logo Datalogic, Quadralogic et Powerscan sont des marques déposées de Datalogic Scanning, Inc. . Toute autre marque ou nom déposé mentionnés ci-après sont les...
Guide de L’utilisateur 61 Déballage et inspection de votre scanner Après avoir ôté de son emballage votre lecteur, bien vérifier le contenu du carton pour s'assurer qu'aucun article commandé ne manque, à savoir : • Le scanner PowerScan RF ; • Le(s) pack(s) batteries ; • Le guide de l'utilisateur (qu...
62 Pow erScan ® RF Douchette Laser Installation de la Batterie Orientez la batterie selon la Schéma 1, puis poussez la dans le scanner jusqu'à ce que vous entendiez un clic de mise en place. Pour enlever la batterie, pressez les deux cotés de la base de la batterie et tirer la pour l'extraire du sca...
64 Pow erScan ® RF Douchette Laser Schéma 2. Conection et Deconnection du Câble (I/F) 2. Consultez votre manuel de terminal HOTE afin de déterminer les paramètres de communication requis pour le Terminal HOTE (e.g., débit, parité, etc…) et, si nécessaire, modifier les paramètres de programmation afi...
Guide de L’utilisateur 65 LED de la base devrait être allumée quand l'unité est branchée à la prise. Schéma 3. Connexion de la Base a L'alimentation 5. Branchez l'alimentation du terminal HOTE. 6. Vérifiez la communication avec le terminal HOTE en pointant un exemplaire de code à barres des dernière...
66 Pow erScan ® RF Douchette Laser La configuration de la base peut être automatiquement chargée sur le scanner. Le téléchargement automatique est configurable et peut être désactivé. Voir " Le Manuel du Système " pour plus d'informations à ce sujet. Si un téléchargement survient, un petit d...
Guide de L’utilisateur 67 Utilisation du PowerScan RF Cette section couvre les sujets suivants : • Chargement et maintenance de la batterie ; • Comment Scanner ; • Indicateurs : LED et Beeper. Chargement et maintenance de la batterie Poser le scanner sur sa base comme montré en Schéma 4, assurez-vou...
Guide de L’utilisateur 69 Chargeur Quatre Emplacements Si vous disposez d'un chargeur 4 emplacements, les batteries sont insérées pour le chargement (voir en Schéma 5). Une charge rapide (90 %) peut être terminée au bout de 2 heures seulement en utilisant cet accessoire optionnel, la moitié du temps...
70 Pow erScan ® RF Douchette Laser Comment Scanner Le Schéma 6 illustre les différentes astuces pour vous aider à avoir de meilleurs résultats de scan : 1. Appliquer un angle entre le scanner et le code. Ne pas tenir le scanner perpendiculairement au code à barres. 2. Le faisceau du scanner doit ent...
Guide de L’utilisateur 71 Profondeur de Champs Il y a quatre différentes profondeurs de champs pour ce scanner. En fonction du type de modèle de votre scanner, vous aurez besoin de placer le pistolet à une distance déterminée du code à barres pour obte-nir des résultats optimum en terme de " sca...
72 Pow erScan ® RF Douchette Laser Schéma 8. Profondeur de champ (HD) NOTE Voir la section intitulée " Définition d'un Mil " pourplus d'information sur la lecture de ce diagramme.Les mesures sont basées sur des modèles HD avecun angle de lecture de 28 ° (contrairement au demiangle de 14 °). ...
Guide de L’utilisateur 73 Schéma 9. Profondeurs de Champs (LR) NOTE Voir la section intitulée " Définition d'un Mil " pourplus d'informations concernant la lecture de ce dia-gramme. Les mesures sont basées sur des modèlesLR avec un angle de lecture de 14° (contrairement àl'angle de lecture d...
Guide de L’utilisateur 75 Indicateurs : LED et Beeper La LED de la base, la LED du scanner et le Beeper sont utilisés pour annoncer l'état du système et représenter les autres signaux usuels. Les tableaux ci dessous répertorient les fonctions des divers indica-teurs. Table 1. Les fonctions de la LED...
76 Pow erScan ® RF Douchette Laser Table 2. Les fonctions de la LED jaune du scanner Table 3. Les fonctions BEEPER du scanner INDICATEUR LED DUREE COMMENTAIRES Indication laser allumé Stable Le LED jaune est allumée lorsque le laser est allumé. INDICATIONS HAUT PARLEUR DUREE COMMENTAIRES Le scanner ...
Guide de L’utilisateur 77 Table 4. Fonction LED de la Base Beep d'erreur de transmission Fort, puis bas, puis fort, puis bas.. Indique l'échec de trans-mission à l'HOTE Beep de connex-ion Faible, puis moyen, et fort Indique que le scanner a été lié à la base avec suc-cès Beep de décon-nexion Fort, p...
78 Pow erScan ® RF Douchette Laser Charge(Batterie) Flash continus Lorsqu'un scanner est emboîté dans la base, il indique que la batterie est en charge rapide Illuminée etconstamment Lorsqu'un scanner est emboîté dans la base, il indique que sa batterie est quasiment chargée. Non illuminée Un scanne...
Guide de L’utilisateur 79 Les Symbologies Actives Les symbologies actives des codes ( disponibles) dans la configuration standard sont : • Code 39 (C39) • Code 128 (C128) • 2 parmi 5 entrelacé (I2of5) Votre scanner devrait être pré programmé avec ces paramètres stan-dards, à moins que … … il vous a ...
80 Pow erScan ® RF Douchette Laser Schéma 11. Etiquetage et Nomenclature du Scanner 1. Gâchette 4. Crochet de suspension 2. Fenêtre 5. LED jaune 3. LED verte 6. Batterie CAUTION—LA S ER RADIATION WHEN OPEN. AVOID EXPO S URE TO BEAM. COVERED BY ONE OR MORE OF THE FOLLOWING PATENT S : 4 , 3 8 7 , 2 9 ...
Guide de L’utilisateur 81 Securite Le scanner PowerScan RF est certifié conforme aux conditions requises par la norme DHHS/CDRH 21CFR sous chapitre J pour les scanner de classe II. Les produits de classe II ne sont pas considérés comme dan-gereux. Le lecteur possède une diode laser d'une longueur d'...
82 Pow erScan ® RF Douchette Laser Interference de la Radio Frequence Cet appareil est conforme au paragraphe 15 du règlement FCC. Les opération sont soumises aux deux conditions suivantes : 1. Cet appareil ne doit pas causer d'interférences nuisibles, et 2. Il doit accepter n'importe quelle interfé...
Guide de L’utilisateur 83 Maintenance La fenêtre de scan nécessite un nettoyage régulier pour enlever les salissures, la poussière et autre débris. Afin d'assurer une performance optimale, nettoyez le vitre du scanner en utilisant un tissus doux imprégné d'alcool isopropyl (ou un équivalent). Voir l...
84 Pow erScan ® RF Douchette Laser • Les scanner est à une distance raisonnable de sa base, sans obstruction majeure entre l'unité radio tel qu'un mur épais ou une machine lourde. (Au moment de l'écriture de ce manuel, la portée maximum en champs libre est de 45 mètres). • Il n'y a pas de signal d'i...
Guide de L’utilisateur 85 Exemplaires de Codes a Barres Utilisez ces codes à barres de test afin de définir la capacité de lecture concernant les différentes symbologies représentées. Code 128 Code 39 2 parmi 5 entrelacé 2 parmi 5 standard Codabar Code 93 C o d e 1 2 8 . T e s t C O D E 3 9 . T E S ...
Manuale d’Istruzioni 87 ITALIANO INDICE Disimballo e ispezione del lettore ................................................................................89Riferimenti ...................................................................................................................89Istruzioni per...
88 P owerScan ® RF Lettore portatile di codici a barre Datalogic Scanning, Inc. 959, Terry StreetEugene, Oregon 87402Telefono (541) 683-5700Telefax (541) 345-7140 Datalogic, il logo Datalogic, Quadralogic II e PowerScan sono marchi registrati di Datalogic Scanning, Inc. Tutti gli altri marchi di fab...
Manuale d’Istruzioni 89 Disimballo e ispezione del lettore Dopo aver disimballato il vostro nuovo lettore, controllate il contenuto dell'imballo per assicurarvi che siano presenti tutti i componenti ordi-nati: • Lettore manuale PowerScan RF • Pacco/i batteria • Guida dell'operatore (questo manuale) ...
90 P owerScan ® RF Lettore portatile di codici a barre Installazione della batteria Orientare la batteria come indicato in Figura 1, quindi spingerla dentro il lettore fino allo scatto in posizione. Per togliere la batteria, premere sulle alette ai lati della base della batteria ed estrarla dal lett...
Manuale d’Istruzioni 91 Verifica funzionale del lettore Dopo aver inserito una batteria carica nel lettore, effettuare la lettura dei codici a barre riportati sul retro del manuale, corrispondenti alle simbologie per le quali è programmato il lettore. Se non sapete come fare, consultate la sezione &...
92 P owerScan ® RF Lettore portatile di codici a barre Figura 2. Collegamento/scollegamento del cavo di interfaccia (I/F) 2. Consultare il manuale del terminale host per determinare i parametri di comunicazione necessari (ad esempio parità, baud rate, ecc.) e, se necessario, modificare i parametri p...
Manuale d’Istruzioni 93 4. Collegare il cavo di alimentazione dell'adattatore di corrente al modulo base e quindi inserire l'adattatore in una presa di cor-rente (Figura 3). Il LED di alimentazione del modulo base si illumina quando l'unità è alimentata correttamente. Figura 3. Collegamento di alime...
94 P owerScan ® RF Lettore portatile di codici a barre La configurazione di sistema del modulo base può essere scaricata automaticamente sul lettore. Questa funzione è configurabile e può essere disabilitata. Vedere il Manuale del sistema per ulteriori infor-mazioni su tale funzione. Lo scaricamento...
Manuale d’Istruzioni 95 Utilizzo di PowerScan RF Questa sezione descrive i seguenti argomenti: • Caricamento e manutenzione della batteria • Come effettuare la lettura • Segnalazioni acustiche e luminose (LED) Caricamento e manutenzione della batteria Questa segnalazione può essere disabilitata medi...
96 P owerScan ® RF Lettore portatile di codici a barre Un lampeggio rapido indica che il caricamento avviene correttamente. Il caricamento viene effettuato rapidamente quando la temperatura della batteria è compresa tra 10 °C e 46 °C e/o la carica della batteria oscilla tra 2.0 e 3.2V. Il tempo di c...
Manuale d’Istruzioni 97 Caricabatterie a 4 vani Se avete un caricabatterie a 4 vani, le batterie vengono inserite per il caricamento come indicato in Figura 5. Con questo accessorio è possi-bile effettuare una carica rapida del 90% in appena due ore, la metà del tempo richiesto per il caricamento su...
98 P owerScan ® RF Lettore portatile di codici a barre Come effettuare la lettura La Figura 6 illustra alcuni suggerimenti per ottenere i migliori risultati di lettura: 1. Il lettore deve essere puntato verso il codice a barre in modo leggermente inclinato. Non tenere il lettore perpendicolare al co...
Manuale d’Istruzioni 99 Profondità di campo Attualmente il lettore è disponibile in quattro modelli. In base al mod-ello, il lettore deve essere tenuto ad una distanza appropriata dal cod-ice a barre per ottenere i migliori risultati di lettura. I diagrammi riportati di seguito forniscono informazio...
Manuale d’Istruzioni 103 Segnalazioni acustiche e luminose (LED) Gli indicatori LED del modulo base ed i LED e il segnalatore acustico del lettore vengono utilizzati per segnalare lo stato operativo del sistema e per fornire altre indicazioni utili. Le tabelle che seguono riportano le funzioni prede...
104 P owerScan ® RF Lettore portatile di codici a barre Tabella 2. Funzioni del LED giallo del lettore Tabella 3. Funzioni del segnalatore acustico del lettore Indicazione Durata Significato Laser attivo Acceso Il LED giallo si illu-mina ogni volta che il laser è attivo. Segnalazione Durata Signific...
Manuale d’Istruzioni 105 Tabella 4. Funzioni dei LED del modulo base Errore di tras-missione Alto, basso, alto, basso Indica che la trasmis-sione al terminale non è andata a buon fine. Connessione Basso, medio, alto. Indica che il lettore si è connesso corretta-mente al modulo base. Disconnes-sione ...
106 P owerScan ® RF Lettore portatile di codici a barre Simbologie abilitate Le simbologie abilitate di codici a barre predefinite dal costruttore sono: • Code 39 (C39) • Code 128 (C128) • Interleaved 2 of 5 (I 2 of 5) Il lettore deve risultare già pre-programmato con queste impostazioni predefinite...
108 P owerScan ® RF Lettore portatile di codici a barre Avvertenze sul laser Il lettore di codici a barre PowerScan RF è certificato negli Stati Uniti per la conformità ai requisiti dello standard DHHS/CRH 21CFR Sub-chapter J for Class II laser products (SR and LR) and Class IIIa (XLR). I prodotti d...
Manuale d’Istruzioni 109 Disturbi in radiofrequenza Questo dispositivo è conforme alla sez. 15 delle norme FCC. L'utilizzo è subordinato alle due condizioni seguenti: 1. Il dispositivo non deve causare interferenze dannose, e 2. Il dispositivo deve sopportare le interferenze captate, incluse quelle ...
110 P owerScan ® RF Lettore portatile di codici a barre Manutenzione Il vetro del lettore deve essere pulito saltuariamente per rimuovere tracce di sporcizia, polvere ed altre impurità. Per ottenere un funziona-mento ottimale, pulire la finestra di scansione con un panno morbido o una salvietta per ...
Manuale d’Istruzioni 111 Risoluzione dei problemi Provate ad eliminare eventuali malfunzionamenti del sistema di lettura in radiofrequenza effettuando i seguenti controlli: • Per il sistema RF, verificare che: • La batteria sia carica. Vedere “Caricamento e manutenzione della batteria” a pag. 95. • ...
112 P owerScan ® RF Lettore portatile di codici a barre (Vedere “Scansione avanzata per codici a barre di difficile let-tura” a pag. 107.) Codici a barre campione Utilizzare questi codici a barre di riferimento per verificare la funzion-alità del lettore nella lettura delle diverse simbologie rappre...
DECLARATION OF CONFORMITY Datalogic hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and Standards: Directives: EMC 89/336/EECLow Voltage 73/23/EECR&TTE 1999/5/EC Standards: EN 300 683:1997 - RadioEN 300 220-3:2000 - Radio Immunit...
Datalogic Manuals
-
Datalogic CBX100
Manual
-
Datalogic F725-E/RF
Manual
-
Datalogic QS2500
Manual
-
Datalogic DS4800
Manual
-
Datalogic DS1100 SH2347
Manual
-
Datalogic Matrix-2000
Manual
-
Datalogic DS2200
Manual
-
Datalogic SR
Manual
-
Datalogic I GD4100
Manual
-
Datalogic Universal Keyboard Wedge Connectivity
Manual
-
Datalogic F734-E
Manual
-
Datalogic Formula
Manual
-
Datalogic Datalogic Jet
Manual
-
Datalogic 90ACC1780
Manual
-
Datalogic TC1100-1200
Manual
-
Datalogic 1000I
Manual
-
Datalogic 9504
Manual
-
Datalogic DS8100A-3002
Manual
-
Datalogic Compact Hand-Held Mobile Computer
Manual
-
Datalogic LR
Manual