Product Reference Guide 1 Table of Contents Introduction ...................................................................................................................................................................................... 7 About this Guide ............................................
Product Reference Guide 7 Chapter 1 Introduction About this Guide This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with...
Introduction 8 Gryphon™ I GD4100 Chapter 11, Data Editing offers advanced configuration options for customization of scanned data output. Chapter 12, Symbologies defines options for all symbologies and provides the programming barcodes necessary for configuring these features. Appendix A, Technical ...
Technical Support Product Reference Guide 9 Technical Support Datalogic Website Support The Datalogic website ( www.scanning.datalogic.com ) is the complete source for technical support and information for Datalogic products. The site offers product support, product registration, warranty informatio...
Product Reference Guide 11 Chapter 2 Getting Started About the Reader Advancements in the LED technology used in this reader significantly improve the illumination of the target field of view, resulting in higher scan efficiency. Whether used in Single Trigger or Continuous Mode, the ergonomic desig...
Getting Started 12 Gryphon™ I GD4100 Install the Interface Cable Connect the reader cable by inserting the cable into the handle as shown in Figure 1 . To remove it, insert a paper clip into the release aperture, then unplug the cable. Figure 1. Connect/disconnect the cable RS-232 Serial Connection ...
Setting Up the Reader Product Reference Guide 13 Keyboard Wedge Connection The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 3 . Figure 3. Keyboard Wedge ...
Getting Started 14 Gryphon™ I GD4100 Figure 5. Other Interface Connections US B IBM K ey bo ard W edg e or... or... NOTE Programming The reader is factory-configured with a set of default features standard. After scanning the interface barcode from the Interfaces section, you can select other option...
Resetting the Standard Product Defaults Product Reference Guide 15 Select the Interface Type Upon completing the physical connection between the reader and its host, proceed directly to "Interfaces"on page 17 for information and programming for the interface type the reader is connected to (...
Product Reference Guide 17 Chapter 3 Interfaces Interface Selection Each reader model will support one of the following sets of host interfaces: General Purpose Models RS-232 RS-232 OPOS USB Keyboard Wedge Retail Point of Sale Models RS-232 RS-232 OPOS USB IBM 46XX Configuring the Interface Scan the...
Global Interface Features Product Reference Guide 21 Global Interface Features The following interface features are configurable by all interface types. To set features specific to your interface, turn to that section of this manual: • RS-232 ONLY Interface on page 51 • Keyboard Interface on page 79...
Interfaces 22 Gryphon™ I GD4100 USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode. ENTER/EXIT PROGRAMMING MODE USB Suspend Mode = Disable USB Suspend Mode = Enable DEFAULT
Product Reference Guide 23 Chapter 4 General Features Double Read Timeout To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Doubl...
General Features 24 Gryphon™ I GD4100 Double Read Timeout — continued ENTER/EXIT PROGRAMMING MODE Double Read Timeout = 0.5 Second Double Read Timeout = 0.6 Second Double Read Timeout = 0.7 Second Double Read Timeout = 0.8 Second Double Read Timeout = 0.9 Second Double Read Timeout = 1 Second
Label Gone Timeout Product Reference Guide 25 Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Ti...
General Features 26 Gryphon™ I GD4100 Label Gone Timeout — cont. ENTER/EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 016 = Timeout of 160 ms
Sleep Mode Timeout Product Reference Guide 27 Sleep Mode Timeout Specifies the timeout value for the reader to enter low power Sleep Mode. When Sleep Mode is enabled the reader cannot receive commands from the Host or base station. In order for the reader to enter Sleep Mode, the following condition...
General Features 28 Gryphon™ I GD4100 Sleep Mode Timeout — continued ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout = 5 Seconds Sleep Mode Timeout = 6 Seconds Sleep Mode Timeout = 7 Seconds Sleep Mode Timeout = 8 Seconds Sleep Mode Timeout = 9 Seconds Sleep Mode Timeout = 10 Seconds max. $ $
LED and Beeper Indicators Product Reference Guide 29 LED and Beeper Indicators Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. ENTER/EXIT PROGRAMMING MODE Power On Alert = Disable (No Audible Indication) Power On Alert = Four Beeps DEFAULT
General Features 30 Gryphon™ I GD4100 Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read =...
LED and Beeper Indicators Product Reference Guide 31 Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. ENTER/EXIT PROGRAMMING MODE Good Read Beep Type = Mono Good Read Beep Type = Bitonal DEFAULT
General Features 32 Gryphon™ I GD4100 Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.) Good Read Beep Length Specifies the duration of a good read beep. ENTER/EXIT PROGRAMMI...
LED and Beeper Indicators Product Reference Guide 33 Good Read Beep Length — continued ENTER/EXIT PROGRAMMING MODE Good Read Beep Length = 80 msec Good Read Beep Length = 100 msec Good Read Beep Length = 120 msec Good Read Beep Length = 140 msec Good Read Beep Length = 160 msec Good Read Beep Length...
General Features 34 Gryphon™ I GD4100 Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. ENTER/EXIT PROGRAMMING MODE Good Read Beep Volume = Beeper Off Good Read Beep Volume = Low Good Read Beep Volume = Medium Good Read Beep V...
LED and Beeper Indicators Product Reference Guide 35 Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 10ms ...
General Features 36 Gryphon™ I GD4100 Good Read LED Duration — cont. ENTER/EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 020 = Good Read LED stays o...
Scanning Features Product Reference Guide 37 Scanning Features Scan Mode Selects the scan operating mode for the reader. Selections are: Trigger Single. When the trigger is pulled, scanning is activated until one of the following occurs: - Scanning Active Time has elapsed - a label has been read- th...
General Features 38 Gryphon™ I GD4100 Scan Mode — continued ENTER/EXIT PROGRAMMING MODE Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode Scan Mode = Trigger Object Sense DEFAULT
Scanning Features Product Reference Guide 39 Stand Mode Triggered Timeout This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode . NOTE ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout = 0.5 Seconds DEFAULT Stand Mode Triggered Timeou...
General Features 40 Gryphon™ I GD4100 Stand Mode Triggered Timeout — continued ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout = 6 Seconds Stand Mode Triggered Timeout = 8 Seconds Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull
Scanning Features Product Reference Guide 41 Stand Detection Specifies the behavior of the scanner when placed in a stand that contains autorecognition hardware. ENTER/EXIT PROGRAMMING MODE Stand Detection = Ignore Autorecognition DEFAULT $ Stand Detection = Switch to object sense Stand Detection = ...
General Features 42 Gryphon™ I GD4100 Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determi...
Scanning Features Product Reference Guide 43 Scanning Active Time — cont. ENTER/EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 005 = Scanning is active...
General Features 44 Gryphon™ I GD4100 Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the des...
Flash On Time Product Reference Guide 45 Flash On Time — cont. ENTER/EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 10 = Flash is ON for 1 Second
General Features 46 Gryphon™ I GD4100 Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the d...
Stand Mode Sensitivity Product Reference Guide 47 Flash Off Time — cont. Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. ENTER/EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save ...
Green Spot Duration Product Reference Guide 49 Green Spot Duration Specifies the duration of the good read pointer beam after a good read. ENTER/EXIT PROGRAMMING MODE Green Spot Duration = Disable (Green Spot is Off ) Green Spot Duration = Short (300 msec) Green Spot Duration = Medium (500 msec) Gre...
Product Reference Guide 51 Chapter 5 RS-232 ONLY Interface Introduction Use the programming barcodes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are ...
RS-232 ONLY Interface 52 Gryphon™ I GD4100 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly. ENTER/EXIT PROGRAMMING MODE Ba...
Baud Rate Product Reference Guide 53 Baud Rate — continued ENTER/EXIT PROGRAMMING MODE Baud Rate = 9600 Baud Rate = 19,200 Baud Rate = 38,400 Baud Rate = 57,600 Baud Rate = 115,200 DEFAULT
RS-232 ONLY Interface 54 Gryphon™ I GD4100 Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. ENTER/EXIT PROGRAMMING MODE 7 Data Bits 8 Data Bits DEFAULT
Stop Bits Product Reference Guide 55 Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the numb...
RS-232 ONLY Interface 56 Gryphon™ I GD4100 Parity This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. • Select None when no parity bit is req...
Handshaking Control Product Reference Guide 57 Handshaking Control The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options: • RTS — RTS ...
Product Reference Guide 59 Chapter 6 RS-232/USB-Com Interfaces Introduction The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces. Standard Factory Settings Reference Appendix C, Standard Defaults for a listing of standard factory settings.
RS-232/USB-Com Interfaces 60 Gryphon™ I GD4100 Intercharacter Delay This parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies ...
Intercharacter Delay Product Reference Guide 61 Intercharacter Delay — cont. ENTER/EXIT PROGRAMMING MODE Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANC...
ACK NAK Options Product Reference Guide 63 ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable ...
RS-232/USB-Com Interfaces 64 Gryphon™ I GD4100 ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. NOTE To set this feature: 1. Determine the desired character or value. 2. Use the ASC...
ACK NAK Options Product Reference Guide 65 ACK Character — cont. ENTER/EXIT PROGRAMMING MODE Select ACK Character Setting DEFAULT 0x06 ‘ACK’ Character
RS-232/USB-Com Interfaces 66 Gryphon™ I GD4100 NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. NOTE To set this feature: 1. Determine the desired character or value. 2. Use the ASC...
ACK NAK Options Product Reference Guide 67 NAK Character — cont. ENTER/EXIT PROGRAMMING MODE Select NAK Character Setting DEFAULT 0x15 ‘NAK’ Character
RS-232/USB-Com Interfaces 68 Gryphon™ I GD4100 ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection o...
ACK NAK Options Product Reference Guide 69 ACK NAK Timeout Value — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 01 ACK NAK Timeout value...
RS-232/USB-Com Interfaces 70 Gryphon™ I GD4100 ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimit...
ACK NAK Options Product Reference Guide 71 ACK NAK Retry Count — cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 003 = 3 Retries
RS-232/USB-Com Interfaces 72 Gryphon™ I GD4100 ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host. Options are: • Ignore errors detected • Process error as valid ACK character • Process error as ...
Indicate Transmission Failure Product Reference Guide 73 Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode ENTER/EXIT PROGRAMMING MODE Indicate Transmission Failure = Disable Indication Indi...
RS-232/USB-Com Interfaces 74 Gryphon™ I GD4100 Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. NOTE To set the value: 1. Determine the desired character or value. A setting of 0xFF indicate...
Disable Character Product Reference Guide 75 Disable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Disable Character Setting DEFAULT 0x44 = Disable Character is ‘D’
RS-232/USB-Com Interfaces 76 Gryphon™ I GD4100 Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. NOTE To set this feature: Determine the desired character or value. A setting of 0xFF indicates ...
Enable Character Product Reference Guide 77 Enable Character — cont. ENTER/EXIT PROGRAMMING MODE Select Enable Character Setting DEFAULT 0x45 = Enable Character is ‘E’
Product Reference Guide 79 Chapter 7 Keyboard Interface Introduction Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Standard Factory Settings Reference Appendix C, Standard Defaults for a listing of standard factory settings. Scancode Tables Inf...
Keyboard Interface 80 Gryphon™ I GD4100 Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. • USB Keyboard (without alternate key encoding) • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key E...
Country Mode Product Reference Guide 81 Country Mode — continued ENTER/EXIT PROGRAMMING MODE Country Mode = Denmark Supports only the interfaces listed in the Country Mode feature description. Country Mode = France Country Mode = Germany Supports only the interfaces listed in the Country Mode fea-tu...
Caps Lock State Product Reference Guide 83 Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps...
Keyboard Interface 84 Gryphon™ I GD4100 Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the host. Reference Appendix F, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 . Characters from 00...
Wedge Quiet Interval Product Reference Guide 85 Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments....
Keyboard Interface 86 Gryphon™ I GD4100 Wedge Quiet Interval — cont. 6 Scan ENTER/EXIT PROGRAMMING MODE ENTER/EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL ST...
Intercode Delay Product Reference Guide 89 Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number ...
Keyboard Interface 90 Gryphon™ I GD4100 Intercode Delay — cont. ENTER/EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 00 = No Wedge Intercode Delay
USB Keyboard Speed Product Reference Guide 91 USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. NOTE ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed = 1ms USB Keyboard Speed = 2ms USB Keyboard Speed = 3ms USB Keyboard Speed = 4ms USB Keyboard Speed = 5ms This feature appl...
Keyboard Interface 92 Gryphon™ I GD4100 USB Keyboard Speed — continued ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed = 6ms USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms
Product Reference Guide 93 Chapter 8 USB-OEM Interface Introduction Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and Chapter 9, IBM 46XX Interface to specifically configure for the USB-OEM interf...
Product Reference Guide 95 Chapter 9 IBM 46XX Interface Introduction Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. IBM Standard Factory Settings Reference Appendix C, Standard Defaults for a listing of standard factory settings.
IBM 46XX Interface 96 Gryphon™ I GD4100 46xx Number of Host Resets Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The configurable range for this feature is 1 to 15 resets. ENTER/...
ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets = 7 46xx Number of Host Resets = 8 46xx Number of Host Resets = 9 46xx Number of Host Resets = 10 46xx Number of Host Resets = 11 46xx Number of Host Resets = 12 46xx Number of Host Resets Product Reference Guide 97 46xx Number of Host Resets — ...
Transmit Labels in Code 39 Format Product Reference Guide 99 Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to an IBM-46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted...
Product Reference Guide 101 Chapter 10 Wand Emulation Interface Introduction This chapter provides feature/settings configuration for the Wand Emulation interface. Wand Emulation Standard Factory Settings Reference Appendix C, Standard Defaults for a listing of standard factory settings. Wand Idle S...
Wand Emulation Interface 102 Gryphon™ I GD4100 Wand Polarity This option specifies the polarity of the Wand output signal. Choices are: • Quiet zones and spaces are high, bars are low • Quiet zones and spaces are low, bars are high NOTE ENTER/EXIT PROGRAMMING MODE Wand Polarity = Quiet Zones & S...
Wand Signal Speed Product Reference Guide 103 Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds NOTE ENTER/EXIT PROGRAMMING MODE Wand Signal Speed = 330ms Wand Signal Speed = 660ms TTL logic level...
Wand Emulation Interface 104 Gryphon™ I GD4100 Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are: • No conversion • Convert to Code 39 symbology • Convert to Code 128 symbology NOTE ENTER/EXIT...
Transmit Noise Product Reference Guide 105 Transmit Noise This option specifies the leading/trailing noise for the Wand interface. Choices are: • Disable (no leading/trailing noise) • Enable leading noise • Enable trailing noise • Enable leading and trailing noise NOTE ENTER/EXIT PROGRAMMING MODE Tr...
Product Reference Guide 107 Chapter 11 Data Editing Data Editing Overview When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.” The features in...
Data Editing 108 Gryphon™ I GD4100 Please Keep In Mind... • Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE. • A prefix or suffi...
Data Editing 110 Gryphon™ I GD4100 Global AIM ID AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), follo...
Global AIM ID Product Reference Guide 111 Global AIM ID — continued ENTER/EXIT PROGRAMMING MODE Global AIM ID = Disable Global AIM ID = Enable DEFAULT
Label ID Product Reference Guide 115 Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Scan the ENTER/EXIT barcode. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suf- fix) by scanning the appropriate barcode...
Data Editing 116 Gryphon™ I GD4100 Label ID — continued Table 18 STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) 2. Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned data using Label ID Control, starting on page 117 Enable as ...
Label ID Product Reference Guide 119 Label ID — continued Label ID Symbology Selection — continued This option selects the symbology for which a Label ID is to be configured. See "Label ID"on page 113 for full instructions. ENTER/EXIT PROGRAMMING MODE Set UPC-E/P5 Label ID Character(s) Set U...
Data Editing 124 Gryphon™ I GD4100 Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. NOTE ENTER/EXIT PROGRAMMING MODE DEFAULT Case Conversion = Disable (no case conversion) Case Conversion = Convert to upper case Case Conversion = Convert...
Character Conversion Product Reference Guide 125 Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character...
Data Editing 126 Gryphon™ I GD4100 Character Conversion — continued ENTER/EXIT PROGRAMMING MODE Configure Character Conversion DEFAULT 0xFFFFFFFFFFFFFFFF
Product Reference Guide 127 Chapter 12 Symbologies Introduction The reader supports the following symbologies (barcode types). Options for each symbology are included in this chapter. • UPC-A • GS1-128 • UPC-E • Interleaved 2 of 5 (I 2 of 5) • EAN 13 (JAN 13) • Datalogic 2 of 5 • EAN 8 (JAN 8) • Cod...
Symbologies 128 Gryphon™ I GD4100 Coupon Control This feature is used to control the reader’s method of processing coupon labels. Options are: • Disable coupon decoding • Enable UPC/EAN coupon decoding • Enable GS1 DataBar coupon decoding To set this feature: 1. Scan the SWITCH bar code. 2. Scan eit...
UPC-A Product Reference Guide 129 UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. ENTER/EXIT PROGRAMMING MODE UPC-A = Disable UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the ch...
Symbologies 130 Gryphon™ I GD4100 UPC-A — cont. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. ENTER/EXIT PROGRAMMING MODE UPC-A to EAN-13 = Don’t Expand UPC-A to EAN-13 = Expand UPC-A Numb...
Symbologies 132 Gryphon™ I GD4100 UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. ENTER/EXIT PROGRAMMING MODE UPC-E = Disable UPC-E = Enable UPC-E Check Character Transmission Enable this option to transmit the ch...
Symbologies 134 Gryphon™ I GD4100 UPC-E — cont. UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. ENTER/EXIT PROGRAMMING MODE UPC-E Number System Character = Do not transmit UPC-E Number System Character = Transmit DEFAULT
Symbologies 136 Gryphon™ I GD4100 GTIN Formatting This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format. NOTE ENTER/EXIT PROGRAMMING MODE GTIN Formatting = Disable GTIN Formatting = Enable If add-on information is present on the...
EAN 13 Product Reference Guide 137 EAN 13 The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 barcodes. ENTER/EXIT PROGRAMMING MODE EAN 13 = Disable EAN 13 = Enable EAN 13 Check Character Transmission Enable this o...
Symbologies 138 Gryphon™ I GD4100 EAN 13 — cont. EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. ENTER/EXIT PROGRAMMING MODE EAN-13 Flag 1 Char= Don’t transmit EAN-13 Flag 1 Char= Transmit DEFAULT
EAN 13 Product Reference Guide 139 EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels. ENTER/EXIT PROGRAMMING MODE EAN-13 ISBN Conversion = Disable EAN-13 ISBN Conversion = Convert to ISBN DEFAULT
Symbologies 140 Gryphon™ I GD4100 EAN 13 — cont. EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE EAN 13 Minimum Reads = 1 EAN 13 Minimum Reads = 2 EAN 13 Minimum Reads ...
EAN 8 Product Reference Guide 141 EAN 8 The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 barcodes. ENTER/EXIT PROGRAMMING MODE EAN 8 = Disable EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to t...
Symbologies 142 Gryphon™ I GD4100 EAN 8 — cont. Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. ENTER/EXIT PROGRAMMING MODE Expand EAN 8 to EAN 13 = Disable Expand EAN 8 to EAN 13 = Enable DEFAULT
EAN 8 Product Reference Guide 143 EAN 8 — cont. EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE EAN 8 Minimum Reads = 1 EAN 8 Minimum Reads = 2 EAN 8 Minimum Read...
Symbologies 144 Gryphon™ I GD4100 UPC/EAN Global Settings This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Decoding Level Decoding Levels are used to configure a barcode...
UPC/EAN Global Settings Product Reference Guide 147 UPC/EAN Global Settings — cont. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits. Options are • Disabled • Enable 4-digit price-weight check-digit calculation • Enable 5-digit price-...
Symbologies 148 Gryphon™ I GD4100 UPC/EAN Global Settings — cont. In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read. In-store labels are defined as UPC-A labels with a number-system character of ...
Add-Ons Product Reference Guide 151 Add-Ons — cont. Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer"on page 154 .) ENTER/EXIT PROGRAMMING MODE O...
Add-Ons Product Reference Guide 157 Add-Ons — cont. P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base labe l ENTER/EXIT PROGRAMMING MODE P2 Add-Ons Minimum Reads = 1 P2 Add-Ons Minimum Reads...
Symbologies 158 Gryphon™ I GD4100 Add-Ons — cont. P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base labe l ENTER/EXIT PROGRAMMING MODE P5 Add-Ons Minimum Reads = 1 P5 Add-Ons Minimum Reads =...
Symbologies 160 Gryphon™ I GD4100 GS1 DataBar™ Omnidirectional The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional barcodes. ENTER/EXIT PROGRAMMIN...
GS1 DataBar™ Omnidirectional Product Reference Guide 161 GS1 DataBar™ Omnidirectional — cont. GS1 DataBar™ Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Omnidirectional label must be decoded before it is accepted as good read ENTER/EXIT P...
Symbologies 162 Gryphon™ I GD4100 GS1 DataBar™ Expanded The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbology. GS1 DataBar™ Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar™ Expanded barcodes. ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Ex...
GS1 DataBar™ Expanded Product Reference Guide 163 GS1 DataBar™ Expanded — cont. GS1 DataBar™ Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Expanded label must be decoded before it is accepted as good read ENTER/EXIT PROGRAMMING MODE GS1 DataBar™...
Symbologies 166 Gryphon™ I GD4100 GS1 DataBar™ Expanded — cont. GS1 DataBar™ Expanded Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar™ Expanded Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beg...
Symbologies 168 Gryphon™ I GD4100 GS1 DataBar™ Expanded — cont. GS1 DataBar™ Expanded Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select GS1 DataBar™ Expanded Set Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beg...
GS1 DataBar™ Limited Product Reference Guide 169 GS1 DataBar™ Limited The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes. ENTER/EXIT PROGRAMMING MODE GS1 D...
Symbologies 170 Gryphon™ I GD4100 GS1 DataBar™ Limited — cont. GS1 DataBar™ Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Limited label must be decoded before it is accepted as good read ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Limited Minimum Re...
Code 39 Product Reference Guide 171 Code 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable When disabled, the reader will not read Code 39 barcodes. ENTER/EXIT PROGRAMMING MODE Code 39 = Disable Code 39 = Enable DEFAULT
Symbologies 172 Gryphon™ I GD4100 Code 39 — cont. Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character ENTER/EXIT PROGRAMMING MODE...
Code 39 Product Reference Guide 173 Code 39 — cont. Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data. ENTER/EXIT PROGRAMMING MODE Code 39 Check Character Transmission = Don’t Send Code 39 Check Character Transmission = Send Code ...
Symbologies 174 Gryphon™ I GD4100 Code 39 — cont. Code 39 Full ASCII In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. ENTER/EXIT PROGRAMMING MODE Code 39 Full ASCII = Disable Code 39 Full ASCII = Enable DEFAULT
Code 39 Product Reference Guide 175 Code 39 — cont. Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label. ENTER/EXIT PROGRAMMING MO...
Symbologies 176 Gryphon™ I GD4100 Code 39 — cont. Code 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE Code 39 Minimum Reads = 1 Code 39 Minimum Reads = 2 Code 39 Minimum R...
Code 39 Product Reference Guide 177 Code 39 — cont. Code 39 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense...
Symbologies 178 Gryphon™ I GD4100 Code 39 — cont. Code 39 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Decoding Level = 1 Code 39 Decoding Level = 2 Code 39 Decoding Level = 3 Code 39 Decoding Level = 4 Code 39 Decoding Level = 5 DEFAULT
Code 39 Product Reference Guide 179 Code 39 — cont. Code 39 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length...
Code 39 Product Reference Guide 181 Code 39 — cont. Code 39 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 02 = Length 1 is ...
Code 39 Product Reference Guide 183 Code 39 — cont. Code 39 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 50 = Length 2 is 50 Ch...
Symbologies 184 Gryphon™ I GD4100 Code 39 — cont. Code 39 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = Disable Code 39 Interdigit Ratio = 1 Code 39 Interdigit Ratio = 2 Code 39 ...
Code 39 Product Reference Guide 185 Code 39 — cont. Code 39 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Interdigit Ratio = 8 Code 39 Interdigit Ratio = 9 Code 39 Interdigit Ratio = 10
Symbologies 186 Gryphon™ I GD4100 Code 39 — cont. Code 39 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read l...
Code 39 Product Reference Guide 187 Code 39 Stitching This option enables/disables stitching for Code 39 labels. When parts of a Code 39 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all ba...
Symbologies 188 Gryphon™ I GD4100 Code 32 The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes. ENTER/EXIT PROGRAMMING MODE Code 32 = Disable Code 32 = Enable Code 32 Feature Setting Except...
Code 32 Product Reference Guide 189 Code 32 — cont. Code 32 Check Character Transmission Enable this option to transmit the check character along with Code 32 barcode data. ENTER/EXIT PROGRAMMING MODE Code 32 Check Character Transmission = Don’t Send Code 32 Check Character Transmission = Send Code ...
Symbologies 190 Gryphon™ I GD4100 Code 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. ENTER/EXIT PROGRAMMING MODE Code 128 = Disable Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disabl...
Code 128 Product Reference Guide 191 Code 128 — cont. Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data. ENTER/EXIT PROGRAMMING MODE Code 128 Check Character Transmission = Don’t Send Code 128 Check Character Transmission = Send...
Symbologies 192 Gryphon™ I GD4100 Code 128 — cont. Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding). ENTER/EXIT PROGRAMMING MODE Code 128 Sub-Code Change Transmission = Disable Code 128 Sub-Code Change Tr...
Symbologies 194 Gryphon™ I GD4100 Code 128 — cont. Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE Code 128 Minimum Reads = 1 Code 128 Minimum Reads = 2 Code 128 Min...
Code 128 Product Reference Guide 195 Code 128 — cont. Code 128 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expe...
Symbologies 196 Gryphon™ I GD4100 Code 128 — cont. Code 128 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 128 Decoding Level = 1 Code 128 Decoding Level = 2 Code 128 Decoding Level = 3 Code 128 Decoding Level = 4 Code 128 Decoding Level = 5 DEFAULT
Code 128 Product Reference Guide 197 Code 128 — cont. Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed le...
Code 128 Product Reference Guide 199 Code 128 — cont. Code 128 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 01 = Length 1...
Code 128 Product Reference Guide 201 Code 128 — cont. Code 128 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 128 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 80 = Length 2 is ...
Symbologies 202 Gryphon™ I GD4100 Code 128 — cont. Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read...
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 205 Interleaved 2 of 5 (I 2 of 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE I 2 of 5 = Disable I 2 of 5 = Enable DEFAULT
Symbologies 206 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character . ENTER/EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation = Disable I 2 of 5 Check C...
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 207 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data. ENTER/EXIT PROGRAMMING MODE I 2 of 5 Check Character Transmission = Don’t Send I ...
Symbologies 208 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads = 1 I 2 of 5 Minimum ...
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 209 Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level NOTE Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 resul...
Symbologies 210 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. 2 of 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE 2 of 5 Decoding Level = 1 2 of 5 Decoding Level = 2 2 of 5 Decoding Level = 3 2 of 5 Decoding Level = 4 2 of 5 Decoding Level = 5 DEFAULT
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 211 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum len...
Symbologies 212 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for I 2 of 5 Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length...
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 213 Interleaved 2 of 5 (I 2 of 5) — cont. Datalogic 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again ...
Symbologies 214 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The lengt...
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 215 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the b...
Symbologies 216 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. ...
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 217 Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Stitching This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled b...
Symbologies 218 Gryphon™ I GD4100 Interleaved 2 of 5 (I 2 of 5) — cont. Follett 2 of 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels. ENTER/EXIT PROGRAMMING MODE Follett 2 of 5 = Disable F...
Datalogic 2 of 5 Product Reference Guide 219 Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 = Disable Datalogic 2 of 5 = En...
Symbologies 220 Gryphon™ I GD4100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Check Character Calculation = Disable Datalo...
Datalogic 2 of 5 Product Reference Guide 221 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads = 1 I 2...
Symbologies 226 Gryphon™ I GD4100 Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFA...
Codabar Product Reference Guide 229 Codabar The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. ENTER/EXIT PROGRAMMING MODE Codabar = Disable Codabar = Enable DEFAULT
Symbologies 230 Gryphon™ I GD4100 Codabar — cont. Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check character in the label is treated as a data character ENTER/EXIT PROGRAMMING MODE...
Codabar Product Reference Guide 231 Codabar — cont. Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data. ENTER/EXIT PROGRAMMING MODE Codabar Check Character Transmission = Don’t Send Codabar Check Character Transmission = Send Codab...
Symbologies 232 Gryphon™ I GD4100 Codabar — cont. Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters ENTER/EXIT PROGRAMMING MODE Codabar Check Character Set = ABCD/TN*E Codabar Check Character Set = ABCD/ABCD Codabar Check Character Set = a...
Codabar Product Reference Guide 233 Codabar — cont. Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match ENTER/EXIT PROGRAMMING MODE Codabar Start/Stop Character Match = Don’t Require Match Codabar Start/Stop Character Match = Require Match . DEF...
Symbologies 234 Gryphon™ I GD4100 Codabar — cont. Codabar Quiet Zones This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label. ENTER/EXIT PROGRAMMING MODE...
Codabar Product Reference Guide 235 Codabar — cont. Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE Codabar Minimum Reads = 1 Codabar Minimum Reads = 2 Codabar Minimum...
Symbologies 236 Gryphon™ I GD4100 Codabar — cont. Codabar Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense o...
Codabar Product Reference Guide 237 Codabar — cont. Codabar Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level = 1 Codabar Decoding Level = 2 Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 DEFAULT
Symbologies 238 Gryphon™ I GD4100 Codabar — cont. Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length d...
Codabar Product Reference Guide 239 Codabar — cont. Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control . Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s st...
Symbologies 240 Gryphon™ I GD4100 Codabar — cont. Codabar Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 03 = Length 1 is 3 Char...
Codabar Product Reference Guide 241 Codabar — cont. Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control . Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode...
Symbologies 242 Gryphon™ I GD4100 Codabar — cont. Codabar Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Codabar Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 50 = Length 2 is 50 Cha...
Codabar Product Reference Guide 243 Codabar — cont. Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = Disable Codabar Interdigit Ratio = 1 Codabar Interdigit Ratio = 2 Codaba...
Symbologies 244 Gryphon™ I GD4100 Codabar — cont. Codabar Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio = 6 Codabar Interdigit Ratio = 7 Codabar Interdigit Ratio = 8 Codabar Interdigit Ratio = 9 Codabar Interdigit Ratio = 10
Codabar Product Reference Guide 245 Codabar — cont. Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read...
Symbologies 246 Gryphon™ I GD4100 Codabar Stitching This option enables/disables stitching for Codabar labels. When parts of a Codabar barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barc...
Code 11 Product Reference Guide 247 Code 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes. ENTER/EXIT PROGRAMMING MODE Code 11 = Disable Code 11 = Enable DEFAULT
Symbologies 248 Gryphon™ I GD4100 Code 11 — cont. Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character. ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Calculation = Disable Code 11 Check Character Calculation = Check C...
Code 11 Product Reference Guide 249 Code 11 — cont. Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Transmission = Don’t Send Code 11 Check Character Transmission = Send DEFAUL...
Symbologies 250 Gryphon™ I GD4100 Code 11 — cont. Code 11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE Code 11 Minimum Reads = 1 Code 11 Minimum Reads = 2 Code 11 Minimum R...
Code 11 Product Reference Guide 251 Code 11 — cont. Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length...
Code 11 Product Reference Guide 253 Code 11 — cont. Code 11 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 04 = Length 1 is ...
Code 11 Product Reference Guide 255 Code 11 — cont. Code 11 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL DEFAULT 50 = Length 2 is 50 C...
Symbologies 256 Gryphon™ I GD4100 Code 11 — cont. Code 11 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels. ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = Disable Code 11 Interdigit Ratio = 1 Code 11 Interdigit Ratio = 2 Code11 I...
Code 11 Product Reference Guide 257 Code 11 — cont. Code 11 Interdigit Ratio — cont. ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio = 6 Code 11 Interdigit Ratio = 7 Code 11 Interdigit Ratio = 8 Code 11 Interdigit Ratio = 9 Code 11 Interdigit Ratio = 10
Symbologies 258 Gryphon™ I GD4100 Code 11 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Choosing Level 1 results in a very conservative decoder at the expense of not being able...
Code 11 Product Reference Guide 259 Code 11 — cont. Code 11 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level = 1 Codabar Decoding Level = 2 Codabar Decoding Level = 3 Codabar Decoding Level = 4 Codabar Decoding Level = 5 DEFAULT
Symbologies 260 Gryphon™ I GD4100 Code 11 — cont. Code 11 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read l...
Code 11 Product Reference Guide 261 Code 11 Stitching This option enables/disables stitching for Code 11 labels. When parts of a Code 11 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all ba...
Symbologies 262 Gryphon™ I GD4100 Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 = Disable Standard 2 of 5 = Enable DEFAULT
Standard 2 of 5 Product Reference Guide 263 Standard 2 of 5 — cont. Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character. ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Calculation = Disable ...
Symbologies 264 Gryphon™ I GD4100 Standard 2 of 5 — cont. Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read. ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Minimum Reads = 1 Standard 2 ...
Standard 2 of 5 Product Reference Guide 267 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 1 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANC...
Standard 2 of 5 Product Reference Guide 269 Standard 2 of 5 — cont. Standard 2 of 5 Set Length 2 — cont. ENTER/EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANC...
Standard 2 of 5 Product Reference Guide 271 Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and th...
Symbologies 272 Gryphon™ I GD4100 ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Enable/Disable When disabled, the imager will not read ISBT barcodes. ENTER/EXIT PROGRAMMING MODE ISBT 128 = Disable ISBT 128 = Enable ISBT 128 Concatenation Use this option to enable/disable I...
ISBT 128 Product Reference Guide 273 ISBT 128 — cont. ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. NOTE ENTER/EXIT PROGRAMMING MODE ISBT 128 Force Concatenation = Disable ISBT 128 Force Concatenation = Enable ISBT 128 Advanced Concatenation Options NOTE This...
Symbologies 274 Gryphon™ I GD4100 Code 4 The following options apply to the Code 4 symbology. Code 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels. ENTER/EXIT PROGRAMMING MODE Code 4 = Disable Code 4 = Enable DEFAULT
Code 4 Product Reference Guide 275 Code 4 — cont. Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character. ENTER/EXIT PROGRAMMING MODE Code 4 Check Character Transmission = Don’t Send Code 4 Check Character Transmission = Send Code 4 Hex t...
Symbologies 276 Gryphon™ I GD4100 Code 5 The following options apply to the Code 5 symbology. Code 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels. ENTER/EXIT PROGRAMMING MODE Code 5 = Disable Code 5 = Enable DEFAULT
Code 5 Product Reference Guide 277 Code 5 — cont. Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character. ENTER/EXIT PROGRAMMING MODE Code 5 Check Character Transmission = Don’t Send Code 5 Check Character Transmission = Send Code 5 Hex t...
Symbologies 278 Gryphon™ I GD4100 Code 4 and Code 5 Common Configuration Items The following options apply to both Code 4 and Code 5 symbologies. Code 4 and 5 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a pa...
Code 4 and Code 5 Common Configuration Items Product Reference Guide 279 Code 4 and Code 5 Common Configuration Items — cont. Code 4 and 5 Decoding Level — cont. ENTER/EXIT PROGRAMMING MODE Code 4 and Code 5 Decoding Level = 1 Code 4 and Code 5 Decoding Level = 2 Code 4 and Code 5 Decoding Level = 3...
Product Reference Guide 281 Appendix A Technical Specifications Table 35 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 36 provides Standard Cable Pinouts. Table 35. Technical Specifications Item Description Physical Characteristics Color White/...
Technical Specifications Product Reference Guide 283 Standard Cable Pinouts Figure 10 and Table 36 provide standard pinout information for the Base Station’s interface cable. Figure 10. Standard Cable Pinouts Pin 10 Cable Clip (Latch) To Host Cable Cable Strain Relief Bottom of Scanner Interface Cab...
Product Reference Guide 285 Appendix B LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors...
LED and Beeper Indications Product Reference Guide 287 Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The follo...
Product Reference Guide 289 Appendix C Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provided for recording...
Product Reference Guide 297 Appendix D Sample Barcodes The sample barcodes in this appendix are typical representations for their symbology types. UPC-A EAN-13 Code 39 Code 128 0 1 2 3 4 5 6 7 8 9 0 5 3 4 5 6 7 8 9 0 1 2 3 4 0 123ABC 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 ...
Sample Barcodes 298 Gryphon™ I GD4100 Sample Barcodes — continued Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231 00246897634 5765485 7554628485
Product Reference Guide 301 Appendix E Keypad Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad. 0 1 2 3 4 5
Product Reference Guide 305 Appendix F Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboa...
P roduc t Ref erence Guide 311 Digital In ter fac e — c o n t. Tabl e F-6. S canc ode S et W h en C o n trol Char ac ter is 02
P roduc t Ref erence Guide 313 IBM31xx 102-k ey — c o n t. Tabl e F-8. S canc ode S et W h en C o n trol Char ac ter is 02
314 Gryphon™ I GD4100 IBM XT Tabl e F-9. S canc ode S et W h en C o n trol Char ac ter is 00 or 0 1
P roduc t Ref erence Guide 315 IBM X T — c o n t. Tabl e F-10. S canc ode S et W h en C o ntr ol Char ac ter is 02
Product Reference Guide 319 Index B barcodes cancel 301 numeric barcodes 301 RS-232 baud rate 91 RS-232 parameters parity 82, 218, 272, 274, 276, 279 Beeper Pitch, Good Read 31, 32 Volume, Good Read 34 Beeper, Good Read 29 C Cable Pinouts 283 Clear to Send 57 Code 39 Format 99 Conversion, case 124 C...
ASCII Chart ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. NUL SOH STXETX EOT ENQ ACK BEL BSHT LF VT FF CRSO SI DLE DC1DC2DC3DC4 NAKSYN ETB CAN EM SUBESC FS GSRSUS 00010203040506070809 0A0B 0C0D 0E 0F10111213141516171819 1A1B 1C1D 1E 1F SP !“ #$ % & ’ () * + ,-./...
Datalogic Manuals
-
Datalogic CBX100
Manual
-
Datalogic F725-E/RF
Manual
-
Datalogic XLR
Manual
-
Datalogic QS2500
Manual
-
Datalogic DS4800
Manual
-
Datalogic DS1100 SH2347
Manual
-
Datalogic Matrix-2000
Manual
-
Datalogic DS2200
Manual
-
Datalogic SR
Manual
-
Datalogic Universal Keyboard Wedge Connectivity
Manual
-
Datalogic F734-E
Manual
-
Datalogic Formula
Manual
-
Datalogic Datalogic Jet
Manual
-
Datalogic 90ACC1780
Manual
-
Datalogic TC1100-1200
Manual
-
Datalogic 1000I
Manual
-
Datalogic 9504
Manual
-
Datalogic DS8100A-3002
Manual
-
Datalogic Compact Hand-Held Mobile Computer
Manual
-
Datalogic LR
Manual