Datalogic Multi-Battery Charger - Manual

Datalogic Multi-Battery Charger

Datalogic Multi-Battery Charger – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual


DATALOGIC SKORPIO™

MULTI-BATTERY CHARGER





Figure 1


The Datalogic Skorpio™ Multi-Battery Charger, with its 4 slots,
allows you to charge the Datalogic Skorpio™ and Datalogic
Skorpio-GUN™ battery packs.

TECHNICAL FEATURES

ELECTRICAL

Power supply

12-14 VDC

Max consumption

4 A

Charge time

3 h 30 min Skorpio™
5 h min Skorpio-GUN™

PHYSICAL

Dimensions (LxWxH)

20 x 13.7 x 4.3 cm
(7.9 x 5.4 x 1.7 in)

Weight (without batteries) 687 g (24.2 oz)
LEDs

4 Charger Status LEDs
1 Power on LED

ENVIRONMENTAL

Working temperature

0° to +40 °C (+32° to +104 °F)

Storage temperature

-20° to +70 °C (-4° to +158 °F)

Humidity

95% without condensation

Degree of protection

IP30


CONNECTIONS


Plug the power supply into the connector positioned on the
Datalogic Skorpio™ Multi-Battery Charger base. Then plug the
power supply into a socket.

Figure 2


ACCESSORIES


94ACC4595 FPS18 power supply without power cord
94ACC1150 Power cord EU 3- pin

USING DATALOGIC SKORPIO™ MULTI-BATTERY CHARGER

Charge Function

Correctly insert the battery pack of the Datalogic Skorpio™ or
of the Datalogic Skoprio-GUN™ into one of the free slots:
simply press it into the slot until the battery latch is
automatically closed; charging starts automatically.

Figure 3


To remove the battery pack release the latch on the charger
for the Datalogic Skorpio™ and the latch on the gun battery
pack for the Datalogic Skorpio-GUN™ as indicated in figure 4:

Figure 4


Battery Charging Status LED Description

LED

Status

Power

Green

It is constant when the
battery charger is powered

Charger Green

Empty

slot

Red

Charging

Green Charge

completed

Orange

blinking

Error



COMPLIANCE

FCC Compliance


Modifications or changes to this equipment without the
expressed written approval of Datalogic could void the
authority to use the equipment.

This device complies with PART 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
which may cause undesired operation.

This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.








822000761 (Rev. B)

Battery Charging State LEDs

Power on LED

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Datalogic Models

All Datalogic Other