Page 2 - CONTENTS; NOTE
CONTENTS DS6500-100-010 MASTER/SLAVE MODEL ...........................................................................................................1 DS6500-100-011 PROFIBUS MODEL .....................................................................................................................8...
Page 3 - Figure A; Figure B; Figure C; Optical Model; Avalanche photodiode; Baud Rate; Lonworks
DS6500 MASTER/SLAVE MODEL DS6500-100-010 MASTER/SLAVE MODEL Figure A Laser Beam Output Window 1 Figure B Programming Keypad 1 Phase On LED (Yellow) 3 TX Data LED (Green) 2 Power On LED (Red) 4 LCD Display 5 Figure C Main/Aux. Interface 25-pin D-sub Male Connector 1 Lonworks 9-pin Male Connector 2 Lo...
Page 4 - Std Models; Electrical Connections:
DS6500 MASTER/SLAVE MODEL SOFTWARE FEATURES ENVIRONMENTAL FEATURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full...
Page 5 - Pin; -pin Local Lonworks Connectors; Network Termination:; Master; to; Slave
DS6500 MASTER/SLAVE MODEL The details of the connector pins are indicated in the following table: 25-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Tran...
Page 6 - Pass Through Layout; Main Serial Interface
DS6500 MASTER/SLAVE MODEL Connectivity: Point-to-Point Layout DS6500 CAB-600X C-BOX 100 Local Host *P.S. PG6000 * P.S. (Presence Sensor) connected to External Trigger/PS input. Pass Through Layout EN T < < EN T < < *P.S. *P.S. Gryphon DS4600A DS4600A DS6500 CAB-600X C-BOX 100 C-BOX 100 C...
Page 7 - Multiplexer Layout; RS485 HD Main Interface; RS232 Master/Slave Layout
DS6500 MASTER/SLAVE MODEL Multiplexer Layout EN T < < EN T < < *P.S. *P.S. DS4600A DS4600A DS6500 PWR-120 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 MX4000 #0 1 #31 #1 Local Host 1 RS485 HD Main Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. RS232 Master/Slave Lay...
Page 8 - Small Synchronized Network with 2 Readers; C-BOX 100 modified to accept scanner power.; C-BOX 100 modified to accept scanner power.
DS6500 MASTER/SLAVE MODEL Local Lonworks Network CAB-60XX CAB-610X BTK-6000 C-BOX 100** Master Encoder*** BTK-6000 Slave 1 *P.S. Local Host CAB-63XX PWR-120 Small Synchronized Network with 2 Readers * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 100 modified to accept scan...
Page 9 - Large Synchronized Network; Large Synchronized Network with DX6X00 and DS6XXX Scanners
DS6500 MASTER/SLAVE MODEL Large Synchronized Network ** * * P.S. (Presence Sensor) connected to External Trigger/PS input. ** Encoder connected to IN2/ENC input. Large Synchronized Network with DX6X00 and DS6XXX Scanners . 7
Page 12 - -pin female Local Lonworks Connector
DS6500 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital...
Page 13 - Fieldbus; Fieldbus
DS6500 PROFIBUS MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connected to External Trigger/PS input. Pass Through Layout Remote Host EN T < < EN T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS...
Page 14 - Fieldbus Small Synchronized Network
DS6500 PROFIBUS MODEL Local Lonworks Network Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (P...
Page 15 - Ethernet; lines by 16 characters LCD
DS6500 ETHERNET MODEL DS6500-100-012 ETHERNET MODEL Figure A Laser Beam Output Window 1 Figure B Programming Keypad 1 Phase On LED (Yellow) 3 TX Data LED (Green) 2 Power On LED (Red) 4 LCD Display 5 Figure C RJ45 Modular Connector for Ethernet Interface 1 Lonworks 9-pin Female Connector 2 Main/Aux. ...
Page 17 - RJ45 Modular Connector
DS6500 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital...
Page 25 - DS6500 OSCILLATING MIRROR MODEL; assure at least 10°; Oscillating Mirror Skew Angle
DS6500 OSCILLATING MIRROR MODEL DS6500-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output Window 1 1 Oscillating mirror models are used when coverage of a large reading area is required, mainly in picket fence applications. The DS6500 scanner mounts a dedicated optic head with integrated os...
Page 26 - Oscillating Mirror Maximum Aperture and Asymmetry; Aperture
DS6500 OSCILLATING MIRROR MODEL In the above case, the zone where the scan line is perpendicular to the reflecting surface corresponds to a neutral zone at the center of the reading field. The mirror can be deflected up to 40°. Oscillation with respect to the output window median axis is asymmetrica...
Page 27 - COMMON FEATURES
COMMON FEATURES COMMON FEATURES C-BOX 100 Pinout for DS6500: The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DS6500 reader is connected in a network by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Power 1, 3, 5 VS 2, 4, 6 GND 7, 8 ...
Page 28 - Mechanical Installation:; progressively tightening them about half-way; ST-237 Mounting Bracket Overall Dimensions; DS6500 Oscillating Mirror Model Overall Dimensions
COMMON FEATURES Mechanical Installation: The DS6500 reader can be positioned and installed in the best way possible as a result of the Step-A-Head TM feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connecto...
Page 29 - Typical Installations:; Conveyor Direction; ATTENTION; ANSI Grade B minimum
COMMON FEATURES Typical Installations: Standard Installation The DS6500 scanner is mounted on the ST-237 106° mounting bracket which guarantees a built-in Skew angle ( S in the figure below) of 16° with respect to the frame plane (typically the Skew angle should be between 10° - 20°). This avoids th...
Page 31 - CONDITIONS
COMMON FEATURES Reading Diagrams: In the following reading diagrams (0,0) is the center of the laser beam output window. DS6500-100-0XX CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 4 (in) 8 12 16 0 10 20 30 40 50 (cm) 60 20 24 80 3...
Page 33 - RS232 PC-side connections; -pin male connector; 5-pin male connector; RX; How To Build A Simple Interface Test Cable:; PC
COMMON FEATURES User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable includi...
Page 34 - Laser Safety; AVOID EXPOSURE; LASER RADIATION IS EMITTED FROM THIS APERTURE
COMMON FEATURES Compliance: Laser Safety Figure A Laser Safety Label 1 Identification Label 2 Figure B Warning and Device Class Label 1 Figure C Laser Safety Label 1 1 2 1 1 The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product accor...
Page 35 - Laser Diode Class Label; Power Supply
COMMON FEATURES The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification label on the laser diode used in this device, the followi...