Cleveland PDW-4 - Manual

Cleveland PDW-4

Cleveland PDW-4 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

Cleveland

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]

PRESSURE STEAMERS

Cleveland Standard Features

n

5 psi Operating Pressure in cooking compartments

n

Mechanical interlock prevents unlatching door while compartment
is pressurized

n

Timers, one per compartment, are mechanical style with
audible signal

n

Thermostatic Trap vents cooking compartment automatically

n

Steam Inlet Valves and Exhaust Valves interlocked for
synchronous action

n

8 psi Compartment Safety Valve

n

Capacity per compartment for eight, 12” x 20” x 2 1/2” deep
Cafeteria Pans, or four, 18” x 26” Bun Pans

n

Heavy Duty, free floating, cast aluminum compartment
doors

n

Compartment Door Hinges have adjustable hinge pins and
self-lubricating bushings

n

Door Gasket replaceable without tools

n

Pressure Gauge for compartment Operating Pressure

n

Compartment Slide Racks are removable without tools, for
easy cleaning

n

Type 430 Stainless Steel: external enclosure, Table Top and
eight gauge plate cooking compartments

n

Moisture Separator for incoming steam

n

Pressure Reducing Valve for 12 to 50 psi steam supply
pressure

n

6” Adjustable Legs with flanged feet

Options & Accessories

p

Automatic Steam Inlet and Exhaust Operation (AT-2):
includes 60 minute Automatic Timers and Manual Bypass

p

Second Pressure Reducing Valve for 50 to 120 psi supply
pressure (PRV)

p

Special Compartment Slide Racks

p

12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep

p

Intermediate Pull-Out Shelf (POS)

p

In-Wall Carrier, for wall mounted units only (IWC-PDW)

s

Clean, non toxic, uncontaminated steam is required for all

“Direct Steam” steamers

Shall be _____ Compartments, CLEVELAND, Pressure Steamer,

Model PD- _____ - _____ , for Direct Steam operation,; _____ volts, sin-

gle phase. Each Cooking Compartment equipped with: 60 Minute

Timer; Pressure Safety Valve; Heavy-duty, free floating Door with

Safety Interlock; and synchronous operating Steam Inlet and

Exhaust/Drain Valves. Compartments are mounted to a Low Cabinet

type base or Wall Mounted. Includes a Pressure Reducing Valve

and Moisture Separator.

Short Form Specifications

SECT.

VI

PAGE

9

0707

PRESSURE STEAMERS

2 OR 3 OR 4 COMPARTMENTS
DIRECT STEAM, OPEN STAND
PEDESTAL BASE OR WALL MOUNTED

MODELS

:

2 Compartments

3 Compartments

4 Compartments

c

PDL-2

c

PDL-3

c

PDL-4

c

PDW-2

c

PDW-3

c

PDW-4

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Cleveland Models

All Cleveland Other