  • Page 2 – IIB; Cleveland; Description; for mounting one 6.10 model on top of one 10.10 model; UNIT A; NOTE: Overall height of unit does not change for units with casters.; NOTE: Overall height of unit does not change for units with casters.; UTILITIES; (Utility connection shown below are listed per unit)
  • Page 3 – for mounting two 6.20 models
  • Page 4 – for mounting one 6.20 model on top of one 10.20 model
  • Page 5 – for mounting two 6.10 models; LEFT SIDE VIEW
  • Page 7 – *Connection for Cleaning Solution
Loading the manual

Cleveland

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]

COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)

SECT.

IIB

PAGE

5A

0707

by

by

Cleveland

Cleveland

Model #

Description

CSTK-610

for mounting two 6.10 models

CSTK-610CA

for mounting two 6.10 models (with casters)

UNIT A

UNIT B

6.00

"

NOTE: Overall height of unit does not change for units with casters.

7

RC

CS

W1

W2

D

G

4.38"

NOTE: Overall height of unit does not change for units with casters.

RC

CS

W1

W2

D

G

RC

CS

W1

W2

D

G

4.38"

38.08"

39.21"

LEFT SIDE VIEW

6.10
on 6.10
GAS

6

UNIT A

UNIT B

3

36.70"

1.58"

2

8

.4

3

5.00"

1.82"

6

7

.8

5

"

2

8

.4

3

6.00"

7

8

.0

0

(M

IN

.H

O

O

D

R

E

Q

U

IR

E

M

E

N

T

)

2.52"

7

UTILITIES

(Utility connection shown below are listed per unit)

Required Clearances:

Rear - 2", Left Side - 4", Right Side - 2 1/2"

• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located

next to the unit.

• Allow for sufficient clearance on left side for service access (contact the

factory service department for recommendations).

• Installation must comply with all local fire and health codes.

Electrical Requirements:

120 volt, 60 Hz, single phase,

UNIT A

- 11.7 amps

Do not connect to a G.F.I. outlet.

UNIT B

- 11.7 amps

Gas Connection:

3/4" NPT

Gas Type:

Natural Gas (Propane optional)

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

Propane Gas - Min. 11" WC / Max. 14" WC

BOILER MODELS

UNIT A

- OGB-6.10

UNIT B

- OGB-6.10

Total Connected Load:

45.400 BTU

45.400 BTU

Steam Generator:

45.400 BTU

45.400 BTU

Hot Air:

45.400 BTU

45.400 BTU

BOILERLESS MODELS

UNIT A

- OGS-6.10

UNIT B

- OGS-6.10

Total Connected Load:

45.400 BTU

45.400 BTU

Hot Air:

45.400 BTU

45.400 BTU

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

Water Connections:

Cold Water (drinking water quality)

Flow Pressure:

30 - 60 PSI

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

Drain Connection:

2" Tube

Venting:

Exhaust Hood required

*Connection for Cleaning Solution

*Connection for Rinse Cycle

*

Available as an option

Note:

For additional connection details, see spec sheet for each

individual combi model to be stacked.

W1

W2

D

RC

S

CS

AV

G

W1

W2

D

RC

S

CS

AV

G

E1

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

W1

W2

D

RC

S

CS

AV

G

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - IIB; Cleveland; Description; for mounting one 6.10 model on top of one 10.10 model; UNIT A; NOTE: Overall height of unit does not change for units with casters.; NOTE: Overall height of unit does not change for units with casters.; UTILITIES; (Utility connection shown below are listed per unit)

Cleveland ™ Project ________________________________ Item __________________________________ Quantity _______________________________ FCSI Section ____________________________ Approval _______________________________ Date __________________________________ 1333 East 179 St., Cleveland, Ohio, U.S.A. ...

Page 3 - for mounting two 6.20 models

Cleveland ™ Project ________________________________ Item __________________________________ Quantity _______________________________ FCSI Section ____________________________ Approval _______________________________ Date __________________________________ 1333 East 179 St., Cleveland, Ohio, U.S.A. ...

Page 4 - for mounting one 6.20 model on top of one 10.20 model

Cleveland ™ Project ________________________________ Item __________________________________ Quantity _______________________________ FCSI Section ____________________________ Approval _______________________________ Date __________________________________ 1333 East 179 St., Cleveland, Ohio, U.S.A. ...

Other Cleveland Models

All Cleveland Other