Page 3 - What is included
B EFORE Y OU B EGIN What is included ¾ 1 x Scorpion™ 55 RG ¾ Warranty Card ¾ User Manual ¾ Power cord Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify th...
Page 4 - Safety Instructions; Please read these instructions carefully, which
Introduction Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance? • Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction ...
Page 5 - NTRODUCTION; Features; DMX Channel Summary
I NTRODUCTION You may notice that both the red and green beams coming out of the projector are larger than the 4.95mW projectors. There is a very distinct reason for this. Unlike 4.95mW projectors the output of the CHAUVET laser projectors with Fatbeam™ technology inside outputs <20mW for each be...
Page 6 - Product Overview
Product Overview DANGER: Laser Radiation emitted from this aperture. Before connecting the unit to AC power, make certain that the front aperture is pointed away from you or others. Fan Sound Sensitivity Knob Dipswitch settings for DMX addressing & other functions DMX connectors Switch selectabl...
Page 7 - General Instructions
AC Power Connection: The unit is supplied with a power plug appropriate to its voltage and destination. Should any other connections be required they must be carried out with the following configuration. Earth = Green/Yellow cable Neutral = Blue cable Live = Brown cable General Instructions Please r...
Page 8 - Laser Safety and Compliance Information
C OMPLIANCE S TATEMENT Your LRG-55 complies with FDA/CDRH 21CFR1040 and Laser Notice 50 as well as IEC 60825- 1:2003. Due to a unique optic design, this product does not exceed output powers that exceed its classification and output levels government agencies have determined to be appropriate for th...
Page 9 - Proper Usage; procedures other than what is specified herein may result in; ONTROL; Dipswitch Chart; Function chart
Proper Usage This unit has been designed to be hung. It is recommended that, for safety purposes, your lighting effect are properly mounted using a suitable hanging clamp and safety cable. CHAUVET offers a range of items, which are ideal for safe mounting. It is the responsibility of the manufacture...
Page 10 - DMX Mode; S E T T I N G T H E S T A R T I N G A D D R E S S; DIP; DIP
DMX Mode In this mode you will be able to control each individual trait of the fixture independently. The LRG-55 occupies 8 channels of DMX control. For detailed listing of the DMX channel values refer to the Appendix section. S E T T I N G T H E S T A R T I N G A D D R E S S This DMX mode enables t...
Page 11 - Operation
Operation Stand-Alone Operation (Sound_Active, Auto Mode): This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode. 1) Set dipswitches position to Sound Active or Auto Mode. Mode Dipswitches Sound Active 10 = Off, 11 = Off, 12 = Off Auto Mode 10 = Of...
Page 12 - Trouble Shooting
Universal DMX Control (DMX Mode): This mode allows you to use a universal DMX-512 controller to control lasers operation and effects. 1) To control your fixture in DMX Mode use standard XLR DMX cable to daisy chain your units together via the XLR connector on the rear of the units. For long cable ru...
Page 13 - PPENDIX; DMX Primer; F I X T U R E L I N K I N G
A PPENDIX DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in...
Page 14 - DMX Quick Reference Chart
DMX Quick Reference Chart DMX Address Quick Reference Chart Dip Switch Position DMX DIP SWITCH SET #9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0=OFF #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1=ON #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 X=OFF or ON #6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 #1 #2 #3 #4 #5 0 0 0 0 0 32 64 96 128 ...
Page 15 - DMX Channel Values
DMX Channel Values Channel Value Function 1 000 Ù 010 011 Ù 120 121 Ù 250 251 Ù 255 Mode Laser off Dynamic Patterns Static Patterns Sound Active Mode 2 000 Ù 255 Pattern Selection Static Patterns – Dynamic Patterns 3 000 Ù 255 X Position Left > Right 4 000 Ù 255 Y Position Top > Bottom 5 000 Ù...
Page 16 - Dynamic Patterns & DMX Values
Dynamic Patterns & DMX Values LRG-55 User Manual 16 11/14/2007/18:46
Page 17 - Static Patterns & DMX Values
LRG-55 User Manual 17 11/14/2007/18:46 Static Patterns & DMX Values LRG-55 User Manual 17 11/14/2007/18:46
Page 18 - General Maintenance; Returns Procedure
General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance a...
Page 19 - Technical Specifications; Technical Support
Technical Specifications WEIGHT & DIMENSIONS Length......................................................................................................................... 256 mm (10.08 in) Width ......................................................................................................