Carrier RHR - Manual

Carrier RHR

Carrier RHR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 5 – Table 3 — Physical Data — Aquazone 50RHS,RVS,RDS015-070 Units
  • Page 6 – Fig. 1 — 50RHC Dimensional Data
  • Page 7 – Fig. 2 — 50RHR Dimensional Data; LEFT RETURN
  • Page 8 – Fig. 3 — 50RHS Dimensional Data
  • Page 9 – UNIT HANGER ISOLATION DETAIL
  • Page 10 – Fig. 5 — 50RVC Dimensional Data
  • Page 11 – Fig. 6 — 50RVR Dimensional Data
  • Page 12 – Fig. 7 — 50RVS Dimensional Data; RIGHT RETURN
  • Page 13 – Fig. 8 — 50RDS Dimensional Data; eps
  • Page 14 – Step 3 — Unit Location —; Fig. 9 — Typical Vertical Installation —; Fig. 10 — Typical Downflow Installation —
  • Page 15 – Side Discharge to Back Discharge; Compressor; Fig. 13 — Horizontal Hanger Bracket
  • Page 16 – not; Fig. 15 — Horizontal Unit Pitch; NOTE: Unit does not need to be sloped toward drain.; Fig. 17 — Vertical Condensate Connection
  • Page 17 – Table 4 — Water Quality Guidelines; Fig. 18 — Typical Ground-Water Piping Installation
  • Page 18 – only
  • Page 19 – Fig. 19 — Typical AquazoneTM Complete C Control Wiring
  • Page 20 – Fig. 20 — Typical AquazoneTM Deluxe D Control Wiring
  • Page 21 – Fig. 21 — Typical AquazoneTM Complete C and LON Controller Wiring
  • Page 22 – Fig. 22 — Typical AquazoneTM Deluxe D and LON Controller Wiring
  • Page 23 – NOTE: Low voltage connector may be removed for easy installation.; Fig. 24 — Low Voltage Field Wiring; TERMINAL STRIP P2; Fig. 26 — Typical D Control Accessory Wiring
  • Page 24 – Table 5 — 50RHC,RVC Electrical Data
  • Page 25 – Table 6 — 50RHR,RVR Electrical Data
  • Page 26 – Table 7 — 50RDS, RHS, RVS Electrical Data; System Checkout —
  • Page 28 – Table 9 — 50RHC,RVC Blower Performance; REHEAT EXTERNAL STATIC PRESSURE (ESP) LOSS
  • Page 30 – Table 13 — 50RHS, RVS Blower Performance with HWR; COIL FACE; — External Static Pressure; HWR; — Hot Water Reheat
  • Page 32 – D Control Accessory Relay Configurations —; Table 17 — HWR Operating Modes
  • Page 33 – Table 18 — Operating Limits — 50RHC,RVC Units
  • Page 34 – Table 21 — Typical Unit Operating Pressures and Temperatures
  • Page 35 – Antifreeze —
  • Page 36 – Table 26 — Antifreeze Percentages by Volume; Cooling Tower/Boiler Systems —; ANTIFREEZE
  • Page 37 – Table 27 — Complete C Control Current LED
  • Page 39 – Fig. 29 — Gravity Flow Method
  • Page 40 – Fig. 32 — FP1 and FP2 Thermistor Location; COAX —; Fig. 31 — Thermistor Nominal Resistance
  • Page 41 – Table 30 — Troubleshooting
  • Page 44 – HEATING CYCLE ANALYSIS; = SUCTION TEMPERATURE – SUCTION SATURATION TEMPERATURE; SUBCOOLING; = DISCHARGE SATURATION TEMPERATURE – LIQUID LINE TEMPERATURE
Loading the manual

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53500007-01

Printed in U.S.A.

Form 50R-5SI

Pg 1

6-07

Replaces: 50R-4SI

Book 1

4

Tab

5a 5a

Installation, Start-Up, and

Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . .1,2

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26

Step 1 — Check Jobsite

. . . . . . . . . . . . . . . . . . . . . . . . 2

Step 2 — Check Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . 2

• STORAGE

• PROTECTION

• INSPECT UNIT

Step 3 — Unit Location

. . . . . . . . . . . . . . . . . . . . . . . . . . 14

• FIELD CONVERSION OF DISCHARGE AIR

Step 4 — Mounting the Unit

. . . . . . . . . . . . . . . . . . . . . 15

• HORIZONTAL UNITS

• VERTICAL UNITS

Step 5 — Duct System

. . . . . . . . . . . . . . . . . . . . . . . . . . 15

• SOUND ATTENUATION

• EXISTING DUCT SYSTEM

Step 6 — Condensate Drain

. . . . . . . . . . . . . . . . . . . . . 16

• HORIZONTAL UNITS

• VERTICAL UNITS

• VENTING

Step 7 — Piping Connections

. . . . . . . . . . . . . . . . . . . 16

• WATER LOOP APPLICATIONS

• GROUND-WATER APPLICATIONS

• GROUND-LOOP APPLICATIONS

Step 8 — Field Power Supply Wiring

. . . . . . . . . . . . 18

• POWER CONNECTION

• SUPPLY VOLTAGE

• 208-VOLT OPERATION

Step 9 — Field Control Wiring

. . . . . . . . . . . . . . . . . . . 18

• THERMOSTAT CONNECTIONS

• WATER FREEZE PROTECTION

• AIR COIL FREEZE PROTECTION

• ACCESSORY CONNECTIONS

• WATER SOLENOID VALVES

PRE-START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-30

System Checkout

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

PSC Blower Speed Selection

. . . . . . . . . . . . . . . . . . 27

FIELD SELECTABLE INPUTS

. . . . . . . . . . . . . . . 30-32

C Control Jumper Settings

. . . . . . . . . . . . . . . . . . . . 30

C Control DIP Switches

. . . . . . . . . . . . . . . . . . . . . . . 30

D Control Jumper Settings

. . . . . . . . . . . . . . . . . . . . 30

D Control DIP Switches

. . . . . . . . . . . . . . . . . . . . . . . 30

Units with Modulating Hot Water Reheat

(HWR) Option

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

D Control Accessory Relay Configurations

. . . . . 32

Water Valve (Slow Opening)

. . . . . . . . . . . . . . . . . . . 32

Outside Air Damper (OAD)

. . . . . . . . . . . . . . . . . . . . 32

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-36

Operating Limits

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Scroll Compressor Rotation

. . . . . . . . . . . . . . . . . . . . . 33

Unit Start-Up Cooling Mode

. . . . . . . . . . . . . . . . . . . . . 33

Unit Start-Up Heating Mode

. . . . . . . . . . . . . . . . . . . . . 34

Flow Regulation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Page

Flushing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Antifreeze

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Cooling Tower/Boiler Systems

. . . . . . . . . . . . . . . . . . 36

Ground Coupled, Closed Loop and Plateframe

Heat Exchanger Well Systems

. . . . . . . . . . . . . . . . 36

OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36,37

Power Up Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Units with Aquazone Complete C Control

. . . . . . . 36

Units with Aquazone Deluxe D Control

. . . . . . . . . . 36

Units with HWR Option

. . . . . . . . . . . . . . . . . . . . . . . . . . 37

SYSTEM TEST

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37,38

Test Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Retry Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Aquazone Deluxe D Control LED Indicators

. . . . . 38

SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-40

Filters

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Water Coil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Condensate Drain Pans

. . . . . . . . . . . . . . . . . . . . . . . . . 38

Refrigerant System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Compressor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Fan Motors

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Condensate Drain Cleaning

. . . . . . . . . . . . . . . . . . . 39

Air Coil Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Condenser Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . 39

Checking System Charge

. . . . . . . . . . . . . . . . . . . . . 39

Refrigerant Charging

. . . . . . . . . . . . . . . . . . . . . . . . . 40

Air Coil Fan Motor Removal

. . . . . . . . . . . . . . . . . . . . . 40

TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . . . 40-42

Thermistor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Control Sensors

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

50RHC,RVC,RHR,RHS,RVR,RVS,RDS
START-UP CHECKLIST

. . . . . . . . . . . . . . . . . . CL-1, CL-2

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can

be hazardous due to system pressure and electrical compo-

nents. Only trained and qualified service personnel should

install, repair, or service air-conditioning equipment.

Untrained personnel can perform basic maintenance func-

tions of cleaning coils and filters and replacing filters. All other

operations should be performed by trained service personnel.

When working on air-conditioning equipment, observe precau-

tions in the literature, tags and labels attached to the unit, and

other safety precautions that may apply.

Improper installation, adjustment, alteration, service, mainte-

nance, or use can cause explosion, fire, electrical shock or other

conditions which may cause personal injury or property dam-

age. Consult a qualified installer, service agency, or your distrib-

utor or branch for information or assistance. The qualified in-

staller or agency must use factory-authorized kits or accessories

when modifying this product. Refer to the individual instruc-

tions packaged with the kits or accessories when installing.

IMPORTANT: Read the entire instruction manual before

starting installation.

AQUAZONE™

50RHC,RVC,RHR,RHS,

RVR,RVS,RDS006-060

Water Source Heat Pump Units

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 5 - Table 3 — Physical Data — Aquazone 50RHS,RVS,RDS015-070 Units

5 Table 2 — Physical Data — Aquazone™ 50RHR,RVR006-060 Units LEGEND *Size 006 available in 50RHR unit only. NOTES: 1. All units have spring compressor mountings, TXV (thermostatic expansion valve) expansion devices, and 1 / 2 and 3 / 4 -in. electrical knockouts. 2. Size 048 available as high-static ...

Page 6 - Fig. 1 — 50RHC Dimensional Data

6 Fig. 1 — 50RHC Dimensional Data NOTES:1. Condensate is 3 / 4 -in. FPT copper. 2. Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection.3. Hanger kit is factory installed. 50RHC UNITS OVERALL CABINET WATER CONNECTIONS ELECTRICAL KNOCKOUTS (in.) ...

Page 7 - Fig. 2 — 50RHR Dimensional Data; LEFT RETURN

7 Fig. 2 — 50RHR Dimensional Data Front K M Blower O u tlet M L Right Ret u rn Front Left Di s ch a rge 3 C S P B a ck Di s ch a rge Conden sa te 3 /4 “ FTP 3 .25 F Front-View B S P Air Coil C S R B A S P Q P Front K M Blower O u tlet J L Front B S P LEFT RETURN RIGHT RETURN Air Coil C S P Front 1.1...

Other Carrier Models